background image

USSC

27

REPAIR PARTS LIST-6035

KEY

PART #

DESCRIPTION

QTY.

1

25108B

Pedestal Base, Painted

1

2

25171B

Ash Pan Guide, Painted

1

3

25158B

Pedestal Trim, Painted

1

4

25109B

Pedestal, Painted

1

5

25167B

Pedestal Back, Painted

1

6

69364B

Ash Pan, Painted

1

7

69419

Hopper Assembly

1

8

80315

Pressure Switch

1

9

80463

Hopper Lid Switch

1

10

86594

Hopper Lid Switch Rod

1

11

69370B

Hopper Lid - Rear, Painted

1

12

69369B

Hopper Lid - Front, Painted

1

13

25193B

Cabinet Back, Painted

1

14

80462

Power Supply Plug

1

N/S

80461

Power Supply Cord

1

15

80454

Exhaust Blower

1

16

86592

Exhaust Pipe

1

17

89586

Brass Nipple

1

18

89603

Brass Connector

1

N/S

80312

Neoprene Tubing

3 ft.

N/S

80312

Neoprene Tubing

14 in.

19

69367B

Cabinet Side - Left, Painted

1

20

69384B

Access Door, Painted

1

21

891066

Knob

1

22

89824

Magnet Latch

1

23

80469

Circuit Board

1

24

69383

Draft Adjustment Slide

1

25

891066

Knob

1

26

80456

Auger Motor

1

27

83511

Rubber Washer

1

28

891055

Coupling

1

29

80457

Agitator Motor

1

30

891083

Agitator Sprocket

1

31

80460

Terminal Block

1

N/S

80464

Terminal Block Jumper

1

32

80381

Low Limit Switch (F110 Thermodisc- 60T12)

1

33

80381

Distribution Blower Limit Switch (F110 Thermodisc- 60T12)

1

34

80455

Auger Safety Switch (F250 Thermodisc- 60T11)

1

N/S

80459

Wiring Harness

1

N/S

80443

Wire (White - 13”) - Power Supply

1

N/S

80445

Wire (Black - 13”) - Power Supply

1

N/S

80446

Wire (Green - 13”) - Power Supply

1

N/S

80448

Wire (White - 13”) - Common

1

N/S

80465

6 Position Waco

1

35

891058

Chain

1

36

80453

Distribution Blower

1

37

69366B

Cabinet Side - Right, Painted

1

38

891074

Door

1

39

891075

Glass & Gasket

1

40

891079

Bottom Glass Retainer

1

41

891078

Right Side Glass Retainer

1

42

891076

Top Glass Retainer

1

43

891077

Left Side Glass Retainer

2

44

891084

Door Handle

1

N/S

891089

Roller Latch Stop

1

45

89574

Spring Handle

1

46

25170

Gold Trim Bracket

2

47

891073

Gold Trim

1

48

25195B

Air Intake Box, Painted

1

49

891100

Ceramic Brick

1

50

25173

Draft Shut-off

2

51

69363

Burn Pot

1

52

891059

Agitator

1

53

69358

Shaft Collar

1

54

69359

Drive Shaft Weldment

1

55

83510

Drive Shaft Set Coupling

1

56

891057

Drive Shaft Sprocket

1

57

40482

Auger, Cast Iron

1

58

25157B

Ash Dump Shut-off, Painted

2

N/S = NOT SHOWN

FOR MODEL: 6035

Summary of Contents for American Harvest 6035

Page 1: ...or fire officials about restrictions and installation requirements peculiar to your area Do Not Plug this appliance into an electrical outlet before reading and understanding all operations and alway...

Page 2: ...s you re helping CONSERVE AMERICA S ENERGY CONGRATULATIONS Heat Output 50 000 BTU HR Heating Capacity 1 500 Sq Ft Fuel Storage Capacity 60 Lbs Width 28 in 711mm Height 33 in 838mm Depth 28 in 711mm BT...

Page 3: ...alling the product The American Harvest stove is designed to burn shelled corn cherry pits or pelletized fuel such as wood pellets The burning of other solid fuels such as cord wood or wood chips in t...

Page 4: ...attention to the draft setting on your stove Therefore purchasing corn from the same source will help achieve a more consistent burn DONOTUSECORNWITHAHIGHWAXCONTENT WOOD PELLETS As with corn be consis...

Page 5: ...s to side and back wall combustible materials NOTE These are minimum clearances to combustible walls established by the testing lab The amount of room needed on the left side of the unit to access the...

Page 6: ...nlet elevation It is recommended that at least 5 ft of vertical pipe be installed when the appliance is vented directly through a wall This will create some natural draft to prevent the possibility of...

Page 7: ...When venting into an existing masonry or factory built chimney the chimney must be cleaned with all creosote re moved The chimney must be a type suited for solid fuel WARNING The chimney and the chimn...

Page 8: ...end down or with a wind hood Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simulta neous power failure see diagram above Blockage excessive...

Page 9: ...ON IN A MOBILE HOME WARNING DO NOT INSTALL IN SLEEPING ROOM 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 60FAK 3 Stove must be permanently electricall...

Page 10: ...f the opening a 1 clearance is all that is required ALCOVE CLEARANCE RECOMMENDATIONS ALCOVE THROUGH THE WALL INSTALLATION REQUIREMENTS The stove is approved for horizontal exhaust however we recommend...

Page 11: ...th pipe attached towards wall Pipe B will go through the wall thimble F Be careful not to dislodge the thimble Position stove not closer than 1 to the wall NOTE Make sure that you leave enough clearan...

Page 12: ...Intake Optional 60FAK With 90 Degree Elbow or Hood Pest Guard 3 8 Mesh Maximum Clean Out Cover Tee 3 Min Wall Thimble Flashing Rain Cap or Termination Cap Storm Collar 24 Min INSIDE VERTICAL PIPE WIT...

Page 13: ...Non Combustible Hearth Plate Support Bracket Every 5 Feet 1 Min Keep Attic Insulation Away From Pipe THROUGH THE WALL VERTICAL PIPE INSTALLATION WITH TERMINATION THROUGH THE ROOF The Hearth Pad is no...

Page 14: ...gasket WARNING Do not operate unit with broken glass Do not substitute original factory glass You must use only factory authorized glass Do not slam door shut Do not strike glass Do not use abrasive...

Page 15: ...Manual Draft Adjustment Slide in or out to adjust the amount of draft flowing through the firebox Ash Dump Shutoff Pull out to empty ashes out of the firebox area and back heat exchanger area Make su...

Page 16: ...ve you another 3 minutes before fuel feeds in If the fire is burning too fast and the fuel is being burned up too quickly push the manual draft knob in a little to slow the fire down This should be do...

Page 17: ...used if the home is over 2000 square feet or the weather is extremely cold The high heat setting is intended for use with wood pellets and the highest heat setting for corn would be the number 4 sett...

Page 18: ...changes MAINTENANCE INSTRUCTIONS Surfaces on the front of the stove will be extremely hot during operation Always wear heat resistant gloves to perform periodic maintenance Using a wooden stick tap t...

Page 19: ...will require weekly cleaning Cleaner fuels will allow for monthly cleaning of the exhaust system Remove the exhaust pipe from the back of your stove and remove any ash that may have collected in the...

Page 20: ...AUTOMATIC SAFETY FEATURES Power Outage During a power outage the stove will shut down safely It will not automatically restart when the power returns unless the exhaust is still up to temperature see...

Page 21: ...male terminal connectors one for each wire from wall thermostat Back of Circuit Board It is a good idea to use the thermostat option to achieve uniform control over your heating needs If you are gone...

Page 22: ...hown on page Change to a better grade of fuel if necessary See page 4 regarding fuel quality Check that damper control knob is adjusted properly Pull out to increase fire burn Extend PL Vent to 5 Chec...

Page 23: ...ressure switch or relay Check contents of the hopper Add fuel if necessary Have your USSC reseller diagnose the problem and replace the part s Stove runs for 30 minutes and then shuts down Exhaust gas...

Page 24: ...r fly ash in the house Cleaning the window particularly when the stove is operating Leakage on the joints between the combustion fan exhaust pipe and PL vent This will be evidenced by dust on the impe...

Page 25: ...USSC 25 WIRING DIAGRAM...

Page 26: ...26 USSC REPAIR PARTS DIAGRAM 6035...

Page 27: ...ocket 1 31 80460 Terminal Block 1 N S 80464 Terminal Block Jumper 1 32 80381 Low Limit Switch F110 Thermodisc 60T12 1 33 80381 Distribution Blower Limit Switch F110 Thermodisc 60T12 1 34 80455 Auger S...

Page 28: ...AYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESC...

Reviews: