United States Stove Company King Pellet Stove KP130 Owner'S Operation And Instruction Manual Download Page 15

-

15

-

1. 

If the stove is still warm, it will resume feeding fuel and continue to operate normally. If the fire has gone out, 

you will have to press the “OFF” button and then the “ON” button again to begin a new start-up sequence.

2. 

If the stove has cooled-off, it will reset to its “OFF” condition. At this point, you may press the “ON” button and 

the unit will begin a new start-up sequence.

NOTE: The unit will also shut down in the event of an exhaust blower failure; if this is the case, the unit will not re-

start and you must contact Customer Service at (800) 750-2723.

SAFETY AND CONVENIENCE FEATURES

Your pellet stove incorporates a safety pressure switch that helps ensure that everything is in proper working 

order before feeding fuel to the burn pot. Because the stove works using an induced draft pressure, the stove 

will not continue to operate if the viewing door is left open; or if the exhaust blower fails or the exhaust system is 

blocked.

The temperature limit control (Thermistor) will prevent your stove from operating at abnormally high temperatures. 

Should the stove temperature begin to approach the factory pre-set limit, the temperature limit control will 

automatically slow down the auger feed rate until the temperature returns to a normal condition. Even though 

the heater will operate on the highest setting, we recommend to operate your heater on this setting for only a 

short period of time. (1 hour etc.)

Your pellet stove also includes an auto-start igniter as a standard feature. The use of other fire starter materials 

(wood chips, starter gel, etc.) is not necessary. By simply pressing the “ON” button on the digital control panel, 

your stove will begin to feed fuel and automatically start within 5 minutes.

TAMPER WARNING

This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal 

regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating 

instructions in this manual.

•  Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards.

• 

Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any 

inspection, cleaning, or maintenance work.

•  Never perform any inspections, cleaning, or maintenance on a hot stove.

• 

Do not operate stove with broken glass , leakage of flue gas may result.

• 

WARNING: The chimney and chimney connector must be kept in good condition and clean.

EXHAUST SYSTEM

Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine 

with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a 

newly started fire or from a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When 

ignited, this creosote makes an extremely hot fire, which may damage the chimney or even destroy the house. 

Despite their high efficiency, pellet stoves can accumulate creosote under certain conditions.

Fly Ash – This accumulates in the horizontal portion of an exhaust run. Though non-combustible, it may impede 

the normal exhaust flow. It should therefore be periodically removed.

Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to 

determine if a creosote or fly ash build-up has occurred. If creosote has accumulated, it should be removed to 

reduce the risk of a chimney fire. Inspect the system at the stove connection and at the chimney top. Cooler 

surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as 

from the bottom. The creosote should be removed with a brush specifically designed for the type of chimney 

in use. A qualified chimney sweep can perform this service. It is also recommended that before each heating 

season the entire system be professionally inspected, cleaned and, if necessary, repaired. To clean the chimney, 

disconnect the vent from the stove.

INTERIOR CHAMBERS

Periodically remove and clean the burnpot and the area inside the burnpot housing. In particular it is advisable 

to clean out the holes in the burnpot to remove any build up that may prevent air from moving through the burn 

pot freely. Remove the two(2) plates on each side of the burnpot housing and clean out that rear chamber.

If a vacuum is used to clean your stove, we suggest using a vacuum designed for ash removal. Some regular 

vacuum cleaner (i.e. shop vacs) may leak ash into the room.

Maintenance

Summary of Contents for King Pellet Stove KP130

Page 1: ...E FOR FUTURE REFERENCE United States Stove Company 227 Industrial Park Road South Pittsburg TN 37380 Please read this entire manual before installation and use of this appliance Failure to follow thes...

Page 2: ...he closed container of ashes should be placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked monthly...

Page 3: ...nimum of 40 lbs per cubic ft 1 4 to 5 16 diameter length no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets th...

Page 4: ...an NFI certified specialist IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 750 272...

Page 5: ...0 203mm CORNER D Adjacent wall to unit 8 00 203mm ALCOVE E Alcove depth 36 00 914mm 5500 M only F Alcove height 60 00 520mm CLEARANCES Your pellet stove has been tested and listed for installation in...

Page 6: ...ove use a 3 inch to 4 inch adapter for 4 inch pipe Connection at back of stove must be sealed using Hi Temp RTV Use 4 inch vent if the vent height is over 12 feet or if the installation is over 2 500...

Page 7: ...ot 2 13m clearance from any grade when adjacent to public walkways E Minimum 2 foot 0 61m clearance above any grass plants or other combustible materials F Minimum 3 foot 0 91m clearance from an force...

Page 8: ...can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowd...

Page 9: ...to the heater Installation SPECIAL MOBILE HOME REQUIREMENTS WARNING Do not install in a sleeping room CAUTION The structural integrity of the mobile home floor wall and ceiling roof must be maintained...

Page 10: ...e a forced draft pressure is required for the combustion process inside your stove it is extremely important that the exhaust system be properly installed and maintained And that when operating your s...

Page 11: ...at will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fa...

Page 12: ...2 conductor wire Put female plug fittings on the lead wires to your low voltage thermostat Plug one thermostat lead onto each of the terminal posts on the circuit board The stove will now drop back t...

Page 13: ...w LEDs will be off 5 Hopper Switch Test The display will show hppr The ON LED is lit If the hopper switch is open lid is open the HEAT RANGE LED will turn on If the lid is closed the HEAT RANGE LED wi...

Page 14: ...the heat exchanger in the stove reaches the factory preset temperature Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater First...

Page 15: ...ck panel or opening the exhaust system for any inspection cleaning or maintenance work Never perform any inspections cleaning or maintenance on a hot stove Do not operate stove with broken glass leaka...

Page 16: ...We recommend using a high quality glass cleaner Should a build up of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass DO NOT use abrasive cleaners DO NOT p...

Page 17: ...re that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system cl...

Page 18: ...tor This indicates that the stove is in normal operation and is running in the automatic mode However either the draft fan or room fan setting is manually configured Flashing Draft Fan Setting Indicat...

Page 19: ...19 GRAY BLACK Wiring Diagram CORRECT WRONG Insure the wires are connected to the bottom two prongs of the hopper switch as shown...

Page 20: ...40 Lock Nut 2 16 25480MB Access Panel 1 17 80461 Power Supply Cord 1 18 80462 Receptacle 3 Prong 1 19 891164 Auger Housing Weldment 1 20 891141 Auger 1 21 891189 Top Bushing Plate 1 22 891132 Bushing...

Page 21: ...21 11 3 2 1 5 6 4 7 9 8 10 12 Parts Diagram 47 46 48 49 50...

Page 22: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 23: ...terruptions or uctuations of electrical power supply to the appliance Non USSC venting components hearth components or other accessories used in conjunction with the appliance USSC s obligation under...

Page 24: ...s pi ces d tach es Gardez ce manuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fi...

Page 25: ...t autoris es et approuv es par crit par USSC et ou 9 les interruptions ou uctuations de l alimentation lectrique de l appareil Composants d vacuation des gaz composants de l tre ou accessoires utilis...

Page 26: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 27: ...2 15 83542 4 40 crou 2 16 25480MB Panneau D acc s 1 17 80461 Cordon D alimentation 1 18 80462 R ceptacle 3 Prong 1 19 891164 Auger Logement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1...

Page 28: ...21 Sch ma des pi ces 11 3 2 1 5 6 4 7 9 8 10 12 47 46 48 49 50...

Page 29: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Page 30: ...eux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur H...

Page 31: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Page 32: ...le et d paisseur correctes doivent tre utilis es NE substituez PAS le verre avec des mat riaux alternatifs Contactez votre revendeur autoris pour obtenir ce verre R installez le nouveau verre en le fi...

Page 33: ...fi peut effectuer ces travaux Il est aussi recommand qu avant chaque saison de chauffage le syst me complet soit inspect nettoy et si n cessaire r par par un professionnel Pour nettoyer la chemin e d...

Page 34: ...sur le bouton OFF arr t et ensuite de nouveau sur le bouton ON marche pour commencer une nouvelle s quence de mise en route 2 Si le po le a refroidi il se r initialisera l tat OFF arr t ce moment l vo...

Page 35: ...de l eau sal e 11 Bois non s ch ou 12 Produits du papier carton contreplaqu ou panneau de particules L interdiction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de pa...

Page 36: ...fin se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois au...

Page 37: ...justez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE L...

Page 38: ...rage forc e est n cessaire au processus de combustion l int rieur de votre po le il est extr mement important que le syst me d vacuation soit install correctement et maintenu Et que lors du fonctionne...

Page 39: ...r Frais Figure 8 Emplacements D vacuation Arriv e EXIGENCES SP CIALES POUR MAISON MOBILE INSTALLATION AUX U UNIQUEMENT AVERTISSEMENT Ne pas installer dans une chambre coucher ATTENTION L int grit stru...

Page 40: ...onducteurs Placez les raccords m les sur les fils de connexion votre thermostat basse tension Branchez un fil de thermostat sur chacun des bornes de la carte de circuit imprim Le po le va maintenant r...

Page 41: ...u regard et le tuyau vertical l int rieur jusqu ce que le niveau du sol soit atteint Avec cette installation vous devez faire attention la ligne d amas de neige la pelouse et les feuilles mortes Nous...

Page 42: ...C D gagement minimum de 3 pieds 0 91m partir de toute construction adjacente D D gagement minimum de 7 pieds 2 13m de tout passage lorsqu il est adjacent des all es publiques E D gagement minimum de 2...

Page 43: ...nnect au raccord de conduite fourni au dos du po le utilisez un adaptateur de 3 4 pouces pour le tuyau de 4 pouces Le raccordement l arri re du po le doit tre scell en utilisant un produit vulcanis RT...

Page 44: ...re minimum plus grand afin d obtenir un acc s commode au panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION...

Page 45: ...cialiste certifi NFI NE CONNECTEZ PAS CETTE UNIT UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR INSTALLATION INCORRECTE Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnem...

Page 46: ...ation of Pellet Fuel Industries Minimum de 40 lbs par pied cube diam tre de 1 4 5 16 longueur non sup rieure 1 5 pas moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres moins de 1 en poids et...

Page 47: ...d entretien ou de nettoyage Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur une...

Page 48: ...des officiels dans vos services locaux de la construction ou des incendies afin de conna tre les restrictions et les exigences d inspection et d terminer si vous avez besoin d un permis de construire...

Reviews: