United States Stove Company KING KP5513 Owner’S Instruction And Operation Manual Download Page 32

© 202

2 Unit

ed Sta

tes S

tov

e Compan

y

25

LA VITRE NOIR

CIT TRÈS R

APIDEMENT

LA FL

AMME EST MOLLE, F

ONCÉE ET SES P

OINTES S

ONT NOIRES 

APRÈS UN CER

TAIN TEMP

S D’UTILIS

ATION D

U POÊLE, LE P

OT DE C

OMBU

STION DÉB

ORDE

Caus

es possibles

Solutions possibles: (Débr

anchez le poêle a

van

t tout

e chose quand c’

est 

possible

.)

Le poêle ou le c

onduit d'évac

uation es

t sale

, ce qui 

limite la cir

cula

tion d'air dans le pot de c

ombustion.

Suiv

ez t

outes les pr

océdur

es de nett

oya

ge de la s

ection d'en

tretien du 

Guide d'utilisation.

Le c

onduit d'évac

uation es

t mal installé

.

Ass

urez

-vous que le c

onduit d'évac

uation ait é

té ins

tallé c

onformémen

aux crit

ères énonc

és dans le Guide d'utilisation.

Le r

egis

tre de tir

age es

t trop f

ermé pour un rég

lage de 

chauff

age éle

vé.

Tire

z le bouton du r

egis

tre de tir

age plus loin v

ers le c

ôté du poêle e

essa

yez de r

allumer l'appareil.

Les orific

es du pot de c

ombustion s

ont bouchés.

Retir

ez le po

t de combus

tion et ne

tto

yez

-le à fond.

Amor

tisseur A

ir est c

ass

é.

Inspecter 

visuellemen

t l’amor

tisseur

. A

ssur

ez-

vous 

que la 

plaque 

d’amor

tissemen

t est fix

é à la tige d’

amortis

seur

. Lor

sque la tig

e de 

l’amor

tisseur es

t déplacé la plaque doit s

e déplacer a

vec elle

.

Blocag

e du conduit d'admis

sion d'air.

Inspecter vis

uellement le c

onduit d'admission d'air qui en

tre dans le po

de combus

tion en recher

chant des c

orps é

trang

ers.

Le v

entila

teur de c

ombustion ne t

ourne pas a

sse

z vite.

Tes

tez la vit

esse de r

ota

tion du ven

tilateur apr

ès avoir ne

tto

yé les pales. 

La vit

esse de r

ota

tion doit êtr

e d'envir

on 3000 t

/min.

Granulés de ma

uvais

e qualité. (Ne 

s’applique qu’

au 

problème « L

A VITRE NOIRCIT TRÈ

S  RAPIDEMENT 

».)

La mar

que ou le lot de gr

anulés utilisés es

t peut-ê

tre de ma

uvais

qualité. S

i possible

, essa

yez une a

utre mar

que de granulés. E

ssa

yez 

aus

si une marque c

omposée d'un a

utre t

ype de bois (résineux plut

ôt que 

feuillus

). Des bois différ

ents pr

ésen

ten

t des car

actéris

tiques différ

entes 

qui affec

ten

t la combus

tion.

L’in

terr

upteur de s

urcha

uffe s

e déclenche tout le t

emps

Caus

es possibles 

Solutions possibles: (Débr

anchez le poêle a

van

t tout

e chose quand c’

est 

possible

.)

Le 

ven

tilateur 

de con

vec

tion sur

chauff

e et 

déclenche 

l'arrêt de t

empérat

ure in

terne

.

Enle

vez la pous

sière des bobina

ges e

t pales de ven

tilateur

. Si le gr

aissa

ge 

du ven

tilateur ne s

uffit pas, il s

e peut que le ven

tilateur s

oit défec

tueux

.

Le poêle es

t res

té s

ur le rég

lage le plus éle

vé pendan

de longues périodes.

En c

as d'utilis

ation du poêle s

ur le rég

lage de cha

uffag

e le plus élevé

il se peut que la t

empérat

ure de la pièc

e s'élève a

u point de cr

éer une 

situa

tion de sur

chauff

e poten

tielle. D

ans ce c

as, es

say

ez d'utilis

er un 

rég

lage de cha

uffag

e inférieur

Un a

utre c

ombustible que les gr

anulés de bois est 

brûlé dans le poêle

.

Ce poêle à gr

anulés a été c

onçu e

t tes

té pour br

ûler des granulés de 

bois. Recher

chez la pr

ésenc

e de combus

tibles autr

e que des granulés 

de bois. Auc

un autr

e type de c

ombustible n'a é

té appr

ouvé pour c

poêle à granulés. E

n prés

ence de signes d'utilis

ation d'a

utres t

ypes de 

combus

tible, c

esse

z immédiatemen

t de les utiliser

.

Sur

tension ou bais

se de t

ension.

Une s

urtension, un pic ou une chut

e de tension peut pr

ovoquer le 

déclenchement du l'in

terr

upteur de s

urcha

uffe. 

Vérifie

z si une prot

ection 

con

tre les s

urtensions es

t installée s

ur le poêle. S

inon, il est c

onseillé 

d'en installer une

.

L'interr

upteur de s

urcha

uffe f

onctionne mal.

Si t

ous les autr

es éléments par

aissen

t corr

ects, r

emplacez l'in

terr

upteur 

de sur

chauff

e.

GUIDE DE DÉP

ANNAGE

Summary of Contents for KING KP5513

Page 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your...

Page 2: ...OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may eff...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...ed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory insta...

Page 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Page 6: ...urpelletstovehasbeentestedandlistedforinstallation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrict...

Page 7: ...mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside Air is mandatory for mobile ho...

Page 8: ...nd to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential b...

Page 9: ...ater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass an...

Page 10: ...venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an exampl...

Page 11: ...raph starting from heat range 1 to heat range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be swit...

Page 12: ...paper cardboard saw dust wax and similar substances for the purpose of starting a fire in an affected wood heater Burning these materials may result in release of toxic fumes or render the heater ine...

Page 13: ...e will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing items on the stovetop during this period because the...

Page 14: ...minutes or longer depending on the heat remaining in the appliance After the stove components stop running all lights on the display will go out and the two digit display will begin flashing E3 REFUE...

Page 15: ...m and the damper should be open for these settings If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push th...

Page 16: ...occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Inspect the system at the stove connection and at the chimney top Cooler surfaces tend to build creosote...

Page 17: ...ing the potential to generate CO CHECK CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed system or pellets that are sticking to...

Page 18: ...ambers Vacuumed Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper end of season Empty Vacuumed For...

Page 19: ...ose the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the inte...

Page 20: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 21: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 22: ...ating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure con...

Page 23: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 24: ...e caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and co...

Page 25: ...l Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blow...

Page 26: ...er Gasket 2 8 80630 Housing PCBA Controller 1 9 80631 Power Board 1 10 80491 Microswitch 1 11 80709 Room Blower 1 12 88347 High Temp Snapdisc Gasget 2 13 80601 High Temp Snapdisc Air 1 14 80599 T Disc...

Page 27: ...2022 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Page 28: ...28 2022 United States Stove Company NOTES...

Page 29: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Page 30: ...ed States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA D...

Page 31: ...nde IR 1 4 69762 Pot de feu 1 5 892668 Couvercles de nettoyage des cendres 2 6 892199 Bo tier contr leur PCBA 1 7 80491 Commutateur de couvercle 1 8 80709 Sou eur de pi ce 1 9 80834 T Disc joint d air...

Page 32: ...lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des boi...

Page 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Page 34: ...e tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v r...

Page 35: ...rm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur d...

Page 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Page 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Page 38: ...e po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 et recommencez Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinage...

Page 39: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant d...

Page 40: ...N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre achet...

Page 41: ...son de chauffage Pour nettoyer la chemin e d connecter l vacuation du po le CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d vacuation Bien qu elles ne soient pas combustib...

Page 42: ...dans le pot de combustion pour liminer toute accumulation qui peut emp cher l air de se d placer travers le pot de combustion librement Echangeur de chaleur Il y a une plaque nettoyer des deux c t s d...

Page 43: ...du po le tous les t moins de l cran s teignent et l cran deux chiffres affiche E3 en clignotant RECHARGE EN COMBUSTIBLE AVERTISSEMENT LA TR MIE ET LE COUVERCLE DU PO LE SONT CHAUDS PENDANT LE FONCTION...

Page 44: ...de combustion ne contient pas de granul s N ouvrez PAS la porte de visualisation Il se peut que le registre doive tre ferm pendant le d marrage N ajoutez PAS de granul s dans le pot de combustion la...

Page 45: ...particules L interdiction de la combustion de ces mat riaux n interdit pas l utilisation des d marreurs de feu fabriqu s partir de papier de carton de sciure de cire et substances similaires dans le...

Page 46: ...eaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage deux chiffres des degr...

Page 47: ...ers un tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez con rmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un in...

Page 48: ...tion de tuyau d au moins 3 pi 0 91 m doit tre ajout e avec un chapeau horizontal pour achever l installation Un support doit tre plac juste au dessous du chapeau de sortie ou raison d un support tous...

Page 49: ...e conduit d vacuation pour po le granul s est con u pour tre d mont aux fins de nettoyage et doit tre v rifi plusieurs fois au cours de la saison de chauffage Le conduit d vacuation pour po le granul...

Page 50: ...ou 101 mm et doit d passer d au moins 36 po 914 mm au dessus de la fa ti re de la maison mobile elle doit tre install e avec un pare feu de plafond et un chapeau anti pluie homologu s UL En cas de d p...

Page 51: ...A Retour Cuisini re U S A 1 26 CAN 8 204 B C t po le U S A 6 153 CAN 8 204 C De l avant au po le U S A 6 153 CAN 8 204 D Retour Flue 2 51 D GAGEMENTS Votre po le granules a t test et r pertori pour un...

Page 52: ...ASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPR...

Page 53: ...bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connecter les install s en usine faisceaux de c blage sur le panneau de c...

Page 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 55: ...uel d crit l installation et le fonctionnement du po le bois USSC 5710 XH Cet appareil de chauffage respecte les limites d mission de bois de berceau de l Environmental Protection Agency des tats Unis...

Page 56: ...ion de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRO...