INSTALL

ATION

ALIMENTATION EN AIR EX

TÉRIEUR 

(EN 

OPTION, S

AUF SI INS

TALLÉ D

ANS UNE MAISON MOBILE

)

Selon vo

tre emplac

ement e

t la 

cons

truc

tion de 

votr

e mais

on, l’air 

ext

érieur peut êtr

e néces

sair

e pour une per

formanc

e optimale

Votr

e poêle est homolo

gué pour ê

tre ins

tallé a

vec une pris

e d’air 

ext

érieur (69F

AK) néc

essair

e pour une maison mobile

. Vous 

pouvez 

acheter 

le 69FAK 

aupr

ès de vo

tre 

rev

endeur d’

appareils 

de chauff

age

. Les ins

truc

tions d’ins

talla

tion son

t fournies a

vec 

le kit d’admis

sion d’air

.

ATTENTION:

NE PAS VENTILER S

OU

S UNE POR

CHE, UNE PONT

, UN 

AU

VENT OU D

ANS TO

UTE ZONE SEMI-

CLO

S OU T

OIT. LE 

FAIRE PEUT 

ENTRAÎNER UN 

FLU

X D'AIR IMPRÉVISIBLE 

AU B

OU

CHON D'ÉVENT DANS CER

TAINE

S CONDITIONS 

ET PEUT AFFECTER LE

S PERFORMANCE

S DE 

VO

TRE POÊLE, 

AINSI QUE D'A

UTRES PR

OBLÈMES IN 

PRÉVISIBLES.

FIXATION DE L

’APP

AREIL AU S

OL

Utilis

ez les tr

ous désignés pour fixer l’

unité a

u sol.

Admis

sion 

D'air Frais

Tuya

u

D'évac

uation

AVER

TISSEMENT 

! - 

N’INSTALLEZ 

PAS 

L’APP

AREIL 

DANS UNE CHAMBRE A C

OU

CHER

ATTENTION ! - L

’INTEGRITE S

TRU

CTURELLE D

PLANCHER DE L

A MAISON MOBILE, DE

S MURS ET D

TOIT DOIT ETRE PRE

SERVEE. 

EN CA

S D’INS

TALL

ATION D

ANS UNE MAIS

ON MOBILE, 

LE POÊLE DOIT ÊTRE MIS À L

A TERRE DIRECTEMENT 

SUR LE CHÂ

SSIS D

’ACIER ET B

OUL

ONNÉ AU S

OL.

Outr

e les critèr

es d’ins

talla

tions détaillés ci-

dessus, l’

installa

tion 

dans une maison mobile s

oit satis

fair

e aux c

onditions suiv

antes:

• L

’appar

eil doit êtr

e fixé a

u sol à l’

aide des tire-

fond dans les 

trous pr

évus à c

et e

ffet dans le s

ocle.

• L

e poêle doit êtr

e mis à la terr

e sur le châ

ssis d’

acier de la 

maison mobile en utilis

ant un fil de c

uivre de 8 GA a

vec une 

rondelle 

striée 

ou en 

étoile 

pour at

taquer 

la pein

tur

e ou 

le 

rev

êtemen

t prot

ecteur a

fin d’as

sur

er la mise à la ma

sse

.

• L

’év

acua

tion doit êtr

e de type « PL » de 3 ou 4 po

. (76 ou 101 

mm) e

t doit dépass

er d’au moins 3

6 po. (

914 mm) a

u-des

sus 

de la f

aîtière 

de la maison mobile; elle 

doit êtr

e ins

tallée a

vec 

un pare-

feu de pla

fond e

t un chapeau an

ti-pluie homologués 

UL.

• E

n cas de déplac

ement de la mais

on mobile, t

outes les s

orties 

ext

érieures doiv

ent ê

tre dépo

sées pendan

t ce déplac

ement. 

Apr

ès la réimplan

tation, t

outes les s

orties e

xtérieur

es doiven

êtr

e réins

tallées e

t refix

ées.

• U

ne prise d’

air ext

érieur est oblig

atoir

e pour l’ins

talla

tion 

dans une maison mobile

. Cons

ultez la s

ection A

dmission d’

air 

ext

érieur et v

otr

e conc

essionnair

e pour l’acha

t.

• V

érifiez a

uprès de v

otr

e municipalité si d’

autr

es codes s

ont 

applicables.

EXIGENCES P

OUR L

’EVAC

UATION

AVER

TISSEMENT

:

• 

INSTALLEZ L

’ÉVAC

UATION DE

S FUMÉES EN 

RESPE

CTANT LE

S DÉGA

GEMENTS SPÉ

CIFIÉS P

AR 

LE FABRIC

ANT D’ÉV

ACU

ATIONS. 

• 

NE RELIEZ PAS L

’ÉVAC

UATION P

OUR P

OÊLE À 

GRANULÉ

S À UNE ÉVAC

UATION UTILISÉE P

OUR UN 

AUTRE APP

AREIL OU UN A

UTRE POÊLE.

• 

N’INSTALLEZ P

AS DE RE

GISTRE DE TIR

AGE S

UR LE 

SYS

TÈME D’ÉV

ACU

ATION DE CET APP

AREIL.

Les 

direc

tives 

d’ins

talla

tion ci-

dessous 

doiven

t êtr

e respec

tées 

pour gar

antir la c

onformit

é tan

t avec la lis

te de s

écurit

é de 

ce poêle 

qu’av

ec les codes 

de cons

truc

tion locaux

. Ne pa

rec

ourir à des méthodes de f

ortune ou à des c

ompromis lor

s de 

l’ins

talla

tion.

IMPOR

TANT

:

CET APPAREIL E

ST É

QUIPÉ D

’UN SYS

TÈME À TIRA

GE 

NÉGA

TIF QUI A

SPIRE L’AIR À TR

AVER

S LE PO

T DE 

COMB

USTION ET P

OU

SSE L

’ÉCHAPPEMENT HOR

DU L

OGEMENT. SI CET APP

AREIL EST C

ONNECTÉ 

À UN SYS

TÈME DE CHEMINÉE AUTRE Q

UE CELUI 

DÉCRIT D

ANS CE MANUEL, IL NE F

ONCTIONNER

A PAS 

CORRE

CTEMENT

.

DISTANCE D

’EVAC

UATION MA

XIMALE

L’ins

talla

tion DOIT compor

ter a

u moins 3 pi (91 cm

) de conduit 

ver

tical 

hors 

de la 

maison. 

Ceci 

crée 

un appel 

d’air 

natur

el qui 

limite le ris

que de fumée ou d’

odeur lors de l’

arrêt de l’

appareil e

évit

e que l’év

acua

tion ne prov

oque des nuisanc

es et un dang

er 

en expo

san

t les personnes ou les buis

sons à des t

empérat

ures 

élevées. L

a haut

eur ver

ticale ma

ximale rec

ommandée pour 

l’év

acua

tion des fumées es

t de 12 pi (3,

66 m) pour une 

Summary of Contents for KING KP5513

Page 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your...

Page 2: ...OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may eff...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...ed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory insta...

Page 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Page 6: ...urpelletstovehasbeentestedandlistedforinstallation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrict...

Page 7: ...mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside Air is mandatory for mobile ho...

Page 8: ...nd to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential b...

Page 9: ...ater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass an...

Page 10: ...venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an exampl...

Page 11: ...raph starting from heat range 1 to heat range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be swit...

Page 12: ...paper cardboard saw dust wax and similar substances for the purpose of starting a fire in an affected wood heater Burning these materials may result in release of toxic fumes or render the heater ine...

Page 13: ...e will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing items on the stovetop during this period because the...

Page 14: ...minutes or longer depending on the heat remaining in the appliance After the stove components stop running all lights on the display will go out and the two digit display will begin flashing E3 REFUE...

Page 15: ...m and the damper should be open for these settings If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push th...

Page 16: ...occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Inspect the system at the stove connection and at the chimney top Cooler surfaces tend to build creosote...

Page 17: ...ing the potential to generate CO CHECK CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed system or pellets that are sticking to...

Page 18: ...ambers Vacuumed Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper end of season Empty Vacuumed For...

Page 19: ...ose the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the inte...

Page 20: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 21: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 22: ...ating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure con...

Page 23: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 24: ...e caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and co...

Page 25: ...l Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blow...

Page 26: ...er Gasket 2 8 80630 Housing PCBA Controller 1 9 80631 Power Board 1 10 80491 Microswitch 1 11 80709 Room Blower 1 12 88347 High Temp Snapdisc Gasget 2 13 80601 High Temp Snapdisc Air 1 14 80599 T Disc...

Page 27: ...2022 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Page 28: ...28 2022 United States Stove Company NOTES...

Page 29: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Page 30: ...ed States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA D...

Page 31: ...nde IR 1 4 69762 Pot de feu 1 5 892668 Couvercles de nettoyage des cendres 2 6 892199 Bo tier contr leur PCBA 1 7 80491 Commutateur de couvercle 1 8 80709 Sou eur de pi ce 1 9 80834 T Disc joint d air...

Page 32: ...lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des boi...

Page 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Page 34: ...e tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v r...

Page 35: ...rm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur d...

Page 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Page 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Page 38: ...e po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 et recommencez Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinage...

Page 39: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant d...

Page 40: ...N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre achet...

Page 41: ...son de chauffage Pour nettoyer la chemin e d connecter l vacuation du po le CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d vacuation Bien qu elles ne soient pas combustib...

Page 42: ...dans le pot de combustion pour liminer toute accumulation qui peut emp cher l air de se d placer travers le pot de combustion librement Echangeur de chaleur Il y a une plaque nettoyer des deux c t s d...

Page 43: ...du po le tous les t moins de l cran s teignent et l cran deux chiffres affiche E3 en clignotant RECHARGE EN COMBUSTIBLE AVERTISSEMENT LA TR MIE ET LE COUVERCLE DU PO LE SONT CHAUDS PENDANT LE FONCTION...

Page 44: ...de combustion ne contient pas de granul s N ouvrez PAS la porte de visualisation Il se peut que le registre doive tre ferm pendant le d marrage N ajoutez PAS de granul s dans le pot de combustion la...

Page 45: ...particules L interdiction de la combustion de ces mat riaux n interdit pas l utilisation des d marreurs de feu fabriqu s partir de papier de carton de sciure de cire et substances similaires dans le...

Page 46: ...eaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage deux chiffres des degr...

Page 47: ...ers un tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez con rmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un in...

Page 48: ...tion de tuyau d au moins 3 pi 0 91 m doit tre ajout e avec un chapeau horizontal pour achever l installation Un support doit tre plac juste au dessous du chapeau de sortie ou raison d un support tous...

Page 49: ...e conduit d vacuation pour po le granul s est con u pour tre d mont aux fins de nettoyage et doit tre v rifi plusieurs fois au cours de la saison de chauffage Le conduit d vacuation pour po le granul...

Page 50: ...ou 101 mm et doit d passer d au moins 36 po 914 mm au dessus de la fa ti re de la maison mobile elle doit tre install e avec un pare feu de plafond et un chapeau anti pluie homologu s UL En cas de d p...

Page 51: ...A Retour Cuisini re U S A 1 26 CAN 8 204 B C t po le U S A 6 153 CAN 8 204 C De l avant au po le U S A 6 153 CAN 8 204 D Retour Flue 2 51 D GAGEMENTS Votre po le granules a t test et r pertori pour un...

Page 52: ...ASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPR...

Page 53: ...bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connecter les install s en usine faisceaux de c blage sur le panneau de c...

Page 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 55: ...uel d crit l installation et le fonctionnement du po le bois USSC 5710 XH Cet appareil de chauffage respecte les limites d mission de bois de berceau de l Environmental Protection Agency des tats Unis...

Page 56: ...ion de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRO...

Reviews: