iNSTALLATiON OPTiONS
read this entire manual before you install and use your pellet stove. Failure to follow instructions may result
in property damage, bodily injury, or even death!
(See specific installation details for clearances and other installation requirements)
A
Freestanding unit
—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with
clearance requirements for a freestanding stove installation.
An
Alcove unit
—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with clearance
requirements for an alcove installation.
Your pellet stove may be installed to code in either a
conventional
or
mobile home
(see SPECIAL MOBILE HOME
REQUIREMENTS).
US Only Installation.
It is recommended that only a authorized technician install your pellet stove, preferably an NFI certified specialist.
DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
iMPrOPEr iNSTALLATiON:
The manufacturer will not be held responsible for damage caused by the malfunc-
tion of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer
if you have any questions.
FLOOr PrOTECTiON
This unit must be installed on a non-combustible floor surface. If a floor pad is used, it should be UL listed or equal.
The floor pad or non-combustible surface should be large enough to extend a minimum of 6 in. (152.4mm) in front, 6 in.
(152.4mm) on each side, and 1 in. (25.4mm) behind the stove (see FIGURE 1).
Floor protection must extend under and 2 in. (50.8mm) to each side of the chimney tee for an interior vertical installation
(see FIGURE 2).
Your pellet stove will need a minimum 31” (787mm) x 38” (965mm) floor protector.
A Floor Protector of 1 inch (25.4mm) thick is recommended for this installation.
Installation