Introduction 
 
The Infresco-S 4kW is part of a family of controllers designed to provide energy saving when 
used  with  Quartz  Infrared  Halogen  Lamps  or  other  Heating  and  Lighting  Products.  The  ‘S’ 
model switches Soft Starts the load each time power is applied  
The microcontroller-based unit incorporates zero-voltage switching and a soft-start function to 
eliminate the lamps’ initial high inrush current – potentially increasing lamp life by as much as 
30%. Installation of the unit is simple and once installed is relatively maintenance-free. 
 
Product Features 
 

 

  Extends Lamp Life. 

  Soft-start/zero-voltage switch-off. 

  Low-cost. 

  Easy to install. 

 

Applications:  patio  areas,  smoking  shelters,  restaurants,  warehouses,  workshops  and 
garden lighting. 

 

Installation 
 
Important
: Read carefully the following information before installing the unit. 

 

The Infresco-S 4kW should be fixed securely using the four mounting holes accessible from 
the  front  of  the  unit.  Remove  the  lid  to  access  the  mounting  holes.  To  ease  installation,  a 
mounting template is provided on the next page to locate the 4 mounting hole centres. 
 
IMPORTANT! The unit must be orientated with the cable glands facing down. 
 
Wiring 

 

It is recommended that installation and maintenance of this equipment should be done with 
reference  to  the  current  edition  of  the  I.E.E.  wiring  regulations  (BS7671)  by  suitably 
qualified/trained  personnel.  These  regulations  contain  important  requirements  regarding 
safety of electrical equipment (for International Standards refer to I.E.C/ directive IEC950). 

 

Warning! Ensure all earth wires are connected to maintain earth continuity to the lamp 
fittings. Isolate the mains supply before wiring this unit. 

 

The unit is fitted with two cable glands. Only one cable should be fitted per gland to maintain 
the  unit’s  IP  rating.  When  fitting  two  lamps,  refer  to  Wiring  Diagram  for an alternative wiring 
configuration using a junction box. 
The mains supply connects to the terminal block marked ‘LINE’. Connect the supply LIVE to 
the ‘L’ terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal. 
The  lamps  connect  to  the  terminal  block  marked  ‘LOAD’.  Connect  the  load  LIVE  to  the  ‘L’ 
terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal. If two lamps are to be 
fitted they must be wired in parallel.

 

Check  all wiring - particularly the line and load connections and make sure the cable glands 
are tightened. 

 

Mounting Template

 

 

 

 
Commissioning 
 
Set the on-time preset (VR1) to a time period of between 1 and 40 minutes. VR1 is located at 
the top of the printed circuit board as shown above. Replace the lid and switch on the mains 
supply to the unit. Press the push-button on the front of the unit to switch the lamps on. 
 
Technical Specification 

 

Supply Voltage   

 

 

 

/- 10% 50 Hz 

Switching Capacity 

 

 

 

4kW Max. 

Current Consumption (control circuit) 

 

50mA 

Terminals 

 

 

 

 

2.5mm

2

 Rising Clamp 

Operating Temperature   

 

 

-20 to 40°C 

Protection Rating 

 

 

 

IP65 

Gland Diameter  

 

 

 

Max Cable Entry 2.5mm² 

Enclosure Dimensions (WxLxH)   

 

100x100x60 (mm) 

 

   

Mounting Template 

 

Use this template to locate the 4 mounting hole 

centres prior to drilling. 

 
 

IMPORTANT! 

The drilling of any additional holes will 

immediately void the warranty of this unit. 

 

The unit must be orientated with the cable 

glands facing down. 

 