Uniteck UNISOLAR 10.24 Manual Download Page 39

ES

 

 

   

www.uniteck.fr

 

39/46

 

 

 

FUNCIONAMIENTO PANEL DE CONTROL  

 

 

 

 

 

 

 

 

 

 

 

 

VISUALIZACIÓN PANEL FOTOVOLTÁICO 

 

 

 
Verde continuo : 
el panel suministra potencia  

 

 

   

 

 
Verde parpadeante : 
La batería es en sobretensión 

 

VISUALIZACOPN CARGA DE LA BATER

ÍA

  

 

 

Verde continuo : 

en carga 

 

 

Verde parpadeante :  

Batería cargada 

 

 
Naranja continuo: 

Batería descargada 

 

Consejo: Si no utiliza la salida 
controlada, reduzca o apague 

sus consumidores 

 

 
Rojo continuo : 

Batería muy descargada 

 

Consejo:  Si  no  utiliza  la 

salida 

controlada, 

apague imperativamente 

sus  consumidores  hasta 
que el indicador vuélvase 

verde. 

VISUALIZACION DE LA SALIDA CONTROLADA 12V/24V  (SEGUN LA BATERÍA)  

 

 

Rojo encendido : 

salida activa 

 

 

 

Rojo parpadeante : 
Sobreconsumo o corto- 
circuito 

 

 

Apagado : Salida inactiva 

 

 

 

 

Verde +Flash

 

Verde

 

Verde + Flash

 

Verde

 

Naranja

 

Rojo

 

Rojo

 

Rojo + Flash

 

Summary of Contents for UNISOLAR 10.24

Page 1: ...uniteck fr Unisolar 20 24 W Regulateur de charge solaire PWM avec sortie contr l e PWM Solar charge controller with controlled output Regulador de carga solar PWM Con salidad controlada 10 24 20 24 3...

Page 2: ...tterie Vert clignotant batterie pleine Vert en charge Rouge batterie profond ment d charg e Connexion panneau solaire Voc 50V Connexion batterie 12V ou 24V Connexion sortie contr l e 12 ou 24V selon b...

Page 3: ...ation solaire Unisolar permet ainsi de recharger parfaitement et 100 toutes les batteries plomb lectrolyte liquide lectrolyte g lifi GEL AGM ou sans entretien Unisolar int gre de plus une sortie 12V 2...

Page 4: ...ment du r gulateur pr voyez un espace libre de 5 cm minimum tout autour du produit Cassez les 2 opercules du capot avec une pince Les c bles sortent via les 2 orifices du capot Fermez le capot en r al...

Page 5: ...ixation Rail Din Fixez directement l Unisolar sur votre cloison l aide de 4 vis non fournies 83 mm 97 mm 60 mm 18 5 mm Fixez le support mural l aide de 3 vis non fournies Clipsez l Unisolar sur le sup...

Page 6: ...n parall le privil gier le c blage en diagonale pour une uniformisation de la charge d charge Ne pas coupler des batteries de capacit s diff rentes d ges diff rents ou de technologies diff rentes A ca...

Page 7: ...ton le voyant actif clignote Choisissez votre technologie batterie en appuyant sur le bouton Liquid Batterie liquide au plomb ouverte Gel Batterie Gel AGM Batterie au plomb sans entretien AGM Pour val...

Page 8: ...pour le mod le 30 24 soit 450W en 12V ou 900W en 24V Certains consommateurs ont un appel de courant au d marrage plus important que la puissance nominale indiqu e Unisolar autorise ces surconsommation...

Page 9: ...Batterie d charg e Conseil Si vous n utilisez pas la sortie contr l e r duisez ou teignez vos consommateurs Rouge continu batterie profond ment d charg e Conseil Si vous n utilisez pas la sortie contr...

Page 10: ...NB Cette tape n intervient pas en mode batterie Gel se r f rer la partie r gulation de la courbe charge selon la technologie batterie En effet si cette tape est r alis e pour ce type de batterie il pe...

Page 11: ...de la batterie Cette tension de gaz ification diverge selon la typologie des batteries AGM ou GEL En fonction du mode s lectionn Unisolar d livre un niveau de tension parfaitement adapt la technologie...

Page 12: ...t mal connect ou en court circuit V rifiez les branchements polarit et connexion Fonctionnement normal la tension du panneau est inf rieure la tension batterie ou ensoleillement trop faible Le panneau...

Page 13: ...ourt circuit en sortie V rifiez les branchements En cas de 1er court circuit le r gulateur r alimentera automatiquement les consommateurs sous 10 secondes En cas de 2e court circuit il est n cessaire...

Page 14: ...ne fois par an Tous les travaux doivent tre r alis s conform ment aux r glements du pays en vigueur en mati re d lectricit Cet appareil n est pas pr vu pour tre utilis par des personnes y compris les...

Page 15: ...n Tension 12 24V D tection automatique S lection type batterie Oui Oui Oui Capacit batterie conseill e 10 150Ah 10 300 Ah 10 450 Ah Compensation temp rature Oui Oui Oui Protection surtension panneau O...

Page 16: ...rance Mail sav uniteck fr Fax 33 0 4 88 04 72 20 GARANTIE La garantie couvre tout d faut ou vice de fabrication pendant 1 an compter de la date d achat pi ces et main d uvre La garantie ne couvre pas...

Page 17: ...harged Command button switch On Off 12V 24V controlled output push 1 second Battery selection push 5 seconds then selection 1 sec Battery selection AGM sealed lead acid battery maintenance free VRLA G...

Page 18: ...nisolar perfectly recharges any lead acid batteries up to 100 Liquid electrolyte Gel cell GEL AGM maintenance free Moreover Unisolar incorporates a 12 24V controlled output to help avoid deep discharg...

Page 19: ...tion for cooling the solar charge controller leave a 5 cm free space minimum all around the product Break the 2 caps of the cover with pliers Cables go out via the 2 orifices of the cover Close the co...

Page 20: ...24 Din Rail mounting Fix the Unisolar directly to The wall using 4 screws not provided 83 mm 97 mm 60 mm 18 5 mm Fix the bracket using 3 screws not provided Clip the Unisolar on its bracket Clip the...

Page 21: ...ps In case of parallel connection favour diagonal wiring for a standardization of the charge discharge Do not couple batteries with different capacities different age or different technologies Prefer...

Page 22: ...old the switch for 5 seconds the active light flickers Select your battery s technology by pressing the button Liquid Open lead acid liquid battery Gel Gel battery AGM Lead battery maintenance free AG...

Page 23: ...00W 24V Some consumers have a current draw when turning on that can be higher than the indicated rating power Unisolar allows those temporary overconsumptions limited to 1 5 times the nominal current...

Page 24: ...tery discharged Tip If you do not use the controlled output reduce or switch off your consumers Steady red Battery deeply discharged Tip If you do not use the controlled output imperatively switch off...

Page 25: ...current decreases battery nearly full NB This stage does not occur with Gel batteries see charge curve regulation depending on the battery technology Indeed if this stage occurs with this type of batt...

Page 26: ...gasification voltage This voltage changes according to the type of the batteries AGM or GEL Depending on the selected mode Unisolar releases a voltage level adapted to the technology of your battery...

Page 27: ...ot properly connected or short circuit Check connections polarity and connection Normal functionning The panel voltage is lower than the battery voltage or too low sunshine The panel gets its charge b...

Page 28: ...ections In case of 1st short circuit solar charge controller will automatically resume recharging consumers within 10 seconds In case of 2nd short circuit you need to restart the 12V output by pushing...

Page 29: ...nections at least once a year All tasks must be realised in compliance with the country regulations in force regarding electricity This device is not designed to be used by people including children w...

Page 30: ...ER Voltage selection 12 24V Automatic detection Battery type selection Yes Yes Yes Recommended battery capacity 10 to 150Ah 10 to 300 Ah 10 to 450 Ah Temperature Compensation Yes Yes Yes Panel overvol...

Page 31: ...sav uniteck fr Fax 33 0 4 88 04 72 20 WARRANTY Warranty covers any defect manufacturing defects for 1 year from the date of its purchase parts and labour Warranty does not cover normal wear of parts...

Page 32: ...rga Rojo bater a muy descargada Bot n de mando On Off Salida controlada 12V 24V Apretar 1 segunda Elecci n bater a apretar 5 segundas pues elecci n 1 sec Elecci n bater a AGM bater a sellada sin mante...

Page 33: ...ar permite as recargar perfectamente y al 100 todas las bater as de plomo a electr lito l quido a electr lito GEL AGM o sin mantenimiento Adem s Unisolar integra una salida 12V 24V controlada evitando...

Page 34: ...regulador prevea un espacio libre de 5 cm m nimum alrededor del producto Rompa los 2 op rculos de la tapa con una pinza Los cables salen via lo 2 agujeros de la tapa Cierre la tapa realizando una empu...

Page 35: ...arril Din Fije directamente el Unisolar sobre su tabique con 4 tornillos no incluyen 83 mm 97 mm 60 mm 18 5 mm Fije el soporte mural con 3 tornillos no provistos Encaje el Unisolar sobre el soporte En...

Page 36: ...alelo privilegie el cableado en diagonal para una uniformaci n de la carga dsecarga No conecte las bater as de differentes capacidades edades o tecnolog as A capacidades iguales preferir una bater a d...

Page 37: ...obre el bot n el indicador activo parpadea Elija su tecnolog a bater a apoyando sobre el bot n o Liquid Bater a liquida al plomo abierta o Gel Bater a GEL o AGM Bater a al plomo sin mantenimiento AGM...

Page 38: ...ra los modelos 30 24 es decir 450W en 12V o 900W en 24V Algunos consumidores tienen un pico de corriente al arranque m s importante que la potencia nominal indicada Unisolar autoriza estos sobreconsum...

Page 39: ...nuo Bater a descargada Consejo Si no utiliza la salida controlada reduzca o apague sus consumidores Rojo continuo Bater a muy descargada Consejo Si no utiliza la salida controlada apague imperativamen...

Page 40: ...ste en modo bater a Gel referirse a la parte regulaci n de la curva de carga seg n la tecnolog a bater a En efecto si esta etapa est realizada para este tipo de bater a puede existir un riesgo de expl...

Page 41: ...ior de la bater a Esta tensi n de desgasificaci n diverge seg n la tipolog a de los bater as AGM o GEL En funci n del modo elegido Unisolar provee un nivel de tensi n perfectamente adaptado a la tecno...

Page 42: ...o o en corto circuito Verifique las conexiones polaridad y conexi n Funcionamiento normal la tensi n del panel es inferior a la tensi n bater a o insolaci n demasiado baja El panel reemprender la carg...

Page 43: ...ados en 3 segundas Corto circuito en salida Verifique las conexiones En caso de 1 corto circuito el regulador alimentar de nuevo los consumidores en 10 segundas En caso de 2 corto circuito es neesario...

Page 44: ...Todos los trabajos deben estar realizados conforme a los reglamentos en vigor del pa s en materia de electricidad Este aparato no es concebido para estar usado por personas ni os incluidos cuyas capac...

Page 45: ...GULADOR DE CARGA Elecci n tensi n 12 24V Detecci n autom tica Elecci n tipo bater a S S S Capacidad bater a aconsejada 10 150Ah 10 300 Ah 10 450 Ah Compensaci n temperatura S S S Protecci n sobretensi...

Page 46: ...72 20 GARANTIA La garant a cubre todo defecto o todo vicio de fabricaci n durante 1 a o a partir de la fecha de compra Piezas y mano de obra La garant a no cubre el desgaste normal de las piezas ej ca...