![Uniteck UNISOLAR 10.24 Manual Download Page 30](http://html1.mh-extra.com/html/uniteck/unisolar-10-24/unisolar-10-24_manual_3997928030.webp)
EN
30/46
TECHNICAL SPECIFICATIONS
Unisolar
10/24
Unisolar
20/24
Unisolar
30/24
S
YSTEM
Battery voltage
12V (6 - 2V elements)
24V (12 - 2V elements)
Nominal charging current
10A
20A
30A
Compatible panel
- maximum output power
- recommended voltage
150W-12V batt.
300W-24V batt.
17/19V-12V batt.
34/38V-24V batt.
300W-12V batt.
600W-24V batt.
17/19V-12V batt.
34/38V-24V batt.
450W-12V batt.
900W-24V batt.
17-19V-12V batt.
34-38V-24V batt.
Technology
PWM
PWM
PWM
Protection rating
IP43
IP43
IP43
Maximum cable section
6 mm²
6 mm²
10 mm²
S
OLAR CHARGE CONTROLLER
Voltage selection (12/24V)
Automatic detection
Battery type selection
Yes
Yes
Yes
Recommended battery capacity
10 to 150Ah
10 to 300 Ah
10 to 450 Ah
Temperature Compensation
Yes
Yes
Yes
Panel overvoltageprotection
Yes
Yes
Yes
12/24V
OUTPUT CONTROLLER
Output current
1-10A
1-20A
1-30A
Output
voltage
12/24V
(depending on battery)
Yes
Yes
Yes
Overconsumption protection
Yes
Yes
Yes
Low battery protection
Yes
Yes
Yes
M
ECHANICAL CHARACTERISTICS
Dimensions apart from DIN rail
(LxHXW)
120x110x42
127x150x55
127x150x55
Weight
200g
350g
400g
Din Rail mounting
Non
Oui
Oui
Operating temperature
-35°C > +55°C
Strorage temperature
-35°C > +80°C
U
NDER LOAD DISCONNECTION
Low voltage warning
12V/24V
Consumer disconnection
11,1V/22,2V
Consumer resetting
12,6V/25,2V