TROUBLESHOOTING, CAUSES, REMEDIES

 

 

 

Error message 

Causes 

Solution  

No light switch on 

The solar charge controller 
needs the battery voltage to 
be higher than 6V to be able 
to start when connecting the 
battery 

Check the battery voltage, 
recharge it if necessary. 

Battery polarity reversal 

Check fuse battery 

Battery connection problem 
(cables, terminals...) 

Check connections 

Defective battery 

Replace your battery, 
following the disconnection 
and connection order (refer 
to the installation and 
connection part) 

 

Panel light off while sun 
is present 

Solar panel disconnected, not 
properly connected, or short 
circuit 

Check connections (polarity 
and connection) 

Normal functionning: The 
panel voltage is lower than 

the battery voltage or too low 
sunshine. 

The  panel  gets  its  charge 

back  as  soon  as  the  panel 
voltage  is  higher  than  the 
battery voltage. 

One or several cells of your 
panel are hidden. 

Check the cleanliness of your 
solar panel and make sure 
none of the cells are hidden. 

 

Green + 

Flash

 

Blinking panel light 
(green) 

Battery overvoltage or 
undervoltage 

Disconnect the solar panel, 
then make sure the battery is 
not in a overvoltage state or 
that the voltage of your 
battery coupling does not 
exceed the voltage accepted 
by the solar charge controller 
(12V/24V) 

 

Orange

 

Voyant charge orange 

Battery discharged 

Usual charge, light goes 
green as soon as the battery 
is charged. 

 
 

Summary of Contents for UNIMPPT 80.15/24

Page 1: ...even under changing weather conditions cloudy sky Relative to a standard regulator PWM technology UNIMPPT uses all the voltages of the at least one panels thereby enabling to provide UP TO 40 more en...

Page 2: ...battery in charge intensity cf patterns below PWM Regulator Voltage 18 7 V Intensity 5 43 A generated power 100W Voltage Intensity Vmp 12 5V Imp 5 43 A Output power 67W MPPT Regulator Voltage 18 7 V I...

Page 3: ...25 C cell rectified at 5 C with a temperature coefficient Vmp 0 34 C either 20 2V and with a decrease of the battery voltage of 1V due to an increase in warmth of the panel when the full load sun at 1...

Page 4: ...ge controller among on the market the optimum power point of panel thus verifying if the voltage intensity couple has changed to modify its conversion parameters in input and thus to optimize the out...

Page 5: ...on favour diagonal wiring for a standardization of the charge discharge Do not couple batteries with different capacities different age or different technologies Prefer a high capacity battery to 2 sm...

Page 6: ...ion push 5 secondes then selection 1 sec Battery status Blinking green Full battery Green charging Red battery deeply discharged Solar panel connection 12V or 24V External temperature sensor Battery c...

Page 7: ...EN 30 65 www uniteck fr LATERAL FACES Protection fuses against reverse battery polarity Fuse 20A Rapide Miniblade Type Connexion Unisensor remote sensor...

Page 8: ...isensor remote sensor page 11 Fixing the solar charge controller can be made on a solid stable and dry appropriate flat surface Standard wiring Bulkhead adapter wiring To provide the required air circ...

Page 9: ...NOCT and solar radiation is 800W m A 300W panel produce as show the table below in reality 200W UNIMPPT 80 15 24 which can be converted in input until 200W in 12V and 400W in 24V is perfectly suited...

Page 10: ...f multi panel configuration prefer parallel connexion which ensures an optimum production especially in shading situation Series Parallel In case of parallel coupling the power panel adds up In case s...

Page 11: ...nnect your battery to the solar charge controller and Battery indicator lights on Connect your solar panel to the charge regulator and Refer to pages 6 and 20 Select your battery technology Press and...

Page 12: ...1s Nevertheless you can directly connect the consumers to the battery without going through the connection of the Unimppt thus use more the battery However the overload protections and more important...

Page 13: ...ded to use Unisensor remote sensor In this case UNIMPPT will use as the temperature reference no the ambient temperature measured by the regulator but the temperature measured by the remote sensor UNI...

Page 14: ...discharged Advice If you do not use the controlled output reduce or switch off your consumers Steady red Battery deeply discharged Advice If you do not use the controlled output imperatively switch o...

Page 15: ...equates the charge on all battery elements battery charged at 100 4 RECOND Only in liquid mode this step can stir thanks a pulsed current the electrolyte of your battery for to avoid all stratificati...

Page 16: ...sential to preserve the lifespan of your battery AGM Batteries Mode GEL Batteries Mode Waterproof batteries AGM or GEL require a precise control of the charge voltage to avoid bleeding phenomenons Ble...

Page 17: ...ainst reversed current prevents reversed current towards the solar panel during the night Battery polarity reversal protection Protection against battery overconsumptions controlled output Battery ove...

Page 18: ...properly connected or short circuit Check connections polarity and connection Normal functionning The panel voltage is lower than the battery voltage or too low sunshine The panel gets its charge back...

Page 19: ...rcuit output Check connections In the case of first short circuit the solar charge controller will automatically recharge consumers within 10 seconds In case of second short circuit you need to restar...

Page 20: ...in force regarding electricity The device used in your installation such connectors cables fuse disconnectors must be adapted and in conformity with law and regulations in force in the country for app...

Page 21: ...6 mm Altitude max 2500 m SOLAR CHARGE CONTROLLER Voltage selection 12 24V Adaptive with 6 steps Battery type selection Yes Gel Agm liquid Recommended battery capacity 50 to 500 Ah Temperature Compens...

Page 22: ...k General Manager Uniteck 8 Avenue de Rome Immeuble le Cassis 34350 Vendres France WARRANTY The warranty covers any defect manufacturing flaws for 1 year from the date of its purchase Pieces and workf...