The intern battery voltage varies according to ambient temperature. (30mV per degree). 

 

To  deliver  the  best  voltage  and  avoid  overloading  or  under  loading  of  the  battery  UNIMPPT  is  originally 
equipped with a temperature sensor integrated on regulator gear. With this, UNIMPPT measures the ambient 
temperature to adj

ust charging voltage according to battery manufacturer’s recommendations. (30mV in 12V 

and 60mV in 24V per °C under and over the reference temperature at 25°C). 

 
 
However,  when  there  is  a  temperature  difference 

between the regulator environment and the battery (ex. 
regulator located in a technical room and battery stocked 
in a block), it is recommended to use Unisensor remote 
sensor. In this case, UNIMPPT will use as the temperature 
reference, no the ambient temperature measured by the 
regulator  but  the  temperature  measured  by  the  remote 
sensor.  

 
UNISENSOR  allows  too  to  optimize  voltage 

measurement for more charge precision. Thanks, 

Unisensor,  the  voltage  measurement  doesn’t  do 

that anymore at across the regulator, but directly 
on  the  battery  to  avoid  voltage  drops  cause  by 
wiring. In order to measure and control the charge 
more precisely. 

 

INSTALLATION AND CONNECTION 

 

 

Fix the sensor thanks 2 bolts or double-sided 
sticker to the nearest of the battery.

 

Warning: Do not theard it in the battery

 

 

 

Connect  2  measure  wires  on  Unisensor. 

 

and 

 

 

 

Ensure  that  green  light  is  correctly  turned 
on. If the yellow light is turned on, a polarity 
reversal  occare.  Modify  wiring  until  flash 
green turn on.

 

 

 
 

 

Connect cable between the regulator and the 
sensor.  

 and 

 

 

 

 

 

 
 


 

 

 

 

 

Red wire 

Red  

cable 

Black  

cable 

Black wire 

Summary of Contents for UNIMPPT 80.15/24

Page 1: ...even under changing weather conditions cloudy sky Relative to a standard regulator PWM technology UNIMPPT uses all the voltages of the at least one panels thereby enabling to provide UP TO 40 more en...

Page 2: ...battery in charge intensity cf patterns below PWM Regulator Voltage 18 7 V Intensity 5 43 A generated power 100W Voltage Intensity Vmp 12 5V Imp 5 43 A Output power 67W MPPT Regulator Voltage 18 7 V I...

Page 3: ...25 C cell rectified at 5 C with a temperature coefficient Vmp 0 34 C either 20 2V and with a decrease of the battery voltage of 1V due to an increase in warmth of the panel when the full load sun at 1...

Page 4: ...ge controller among on the market the optimum power point of panel thus verifying if the voltage intensity couple has changed to modify its conversion parameters in input and thus to optimize the out...

Page 5: ...on favour diagonal wiring for a standardization of the charge discharge Do not couple batteries with different capacities different age or different technologies Prefer a high capacity battery to 2 sm...

Page 6: ...ion push 5 secondes then selection 1 sec Battery status Blinking green Full battery Green charging Red battery deeply discharged Solar panel connection 12V or 24V External temperature sensor Battery c...

Page 7: ...EN 30 65 www uniteck fr LATERAL FACES Protection fuses against reverse battery polarity Fuse 20A Rapide Miniblade Type Connexion Unisensor remote sensor...

Page 8: ...isensor remote sensor page 11 Fixing the solar charge controller can be made on a solid stable and dry appropriate flat surface Standard wiring Bulkhead adapter wiring To provide the required air circ...

Page 9: ...NOCT and solar radiation is 800W m A 300W panel produce as show the table below in reality 200W UNIMPPT 80 15 24 which can be converted in input until 200W in 12V and 400W in 24V is perfectly suited...

Page 10: ...f multi panel configuration prefer parallel connexion which ensures an optimum production especially in shading situation Series Parallel In case of parallel coupling the power panel adds up In case s...

Page 11: ...nnect your battery to the solar charge controller and Battery indicator lights on Connect your solar panel to the charge regulator and Refer to pages 6 and 20 Select your battery technology Press and...

Page 12: ...1s Nevertheless you can directly connect the consumers to the battery without going through the connection of the Unimppt thus use more the battery However the overload protections and more important...

Page 13: ...ded to use Unisensor remote sensor In this case UNIMPPT will use as the temperature reference no the ambient temperature measured by the regulator but the temperature measured by the remote sensor UNI...

Page 14: ...discharged Advice If you do not use the controlled output reduce or switch off your consumers Steady red Battery deeply discharged Advice If you do not use the controlled output imperatively switch o...

Page 15: ...equates the charge on all battery elements battery charged at 100 4 RECOND Only in liquid mode this step can stir thanks a pulsed current the electrolyte of your battery for to avoid all stratificati...

Page 16: ...sential to preserve the lifespan of your battery AGM Batteries Mode GEL Batteries Mode Waterproof batteries AGM or GEL require a precise control of the charge voltage to avoid bleeding phenomenons Ble...

Page 17: ...ainst reversed current prevents reversed current towards the solar panel during the night Battery polarity reversal protection Protection against battery overconsumptions controlled output Battery ove...

Page 18: ...properly connected or short circuit Check connections polarity and connection Normal functionning The panel voltage is lower than the battery voltage or too low sunshine The panel gets its charge back...

Page 19: ...rcuit output Check connections In the case of first short circuit the solar charge controller will automatically recharge consumers within 10 seconds In case of second short circuit you need to restar...

Page 20: ...in force regarding electricity The device used in your installation such connectors cables fuse disconnectors must be adapted and in conformity with law and regulations in force in the country for app...

Page 21: ...6 mm Altitude max 2500 m SOLAR CHARGE CONTROLLER Voltage selection 12 24V Adaptive with 6 steps Battery type selection Yes Gel Agm liquid Recommended battery capacity 50 to 500 Ah Temperature Compens...

Page 22: ...k General Manager Uniteck 8 Avenue de Rome Immeuble le Cassis 34350 Vendres France WARRANTY The warranty covers any defect manufacturing flaws for 1 year from the date of its purchase Pieces and workf...

Reviews: