PT630D User Reference Guide
unitech Electronic CO. LTD
Unitech Part Number: 400412
17
keys to return to
User mode prompt
. If you try to display a program or binary file, you may only
see unintelligible characters.
CPY
This command allows users to make copy of data from a source device to a destination device.
The source device may be a file, COM (serial input), CON (keyboard), and the destination device
may be a file, COM (serial output), CON (LCD display).
Source Dest. Function
file1
file2
copy file1 to file2
file1
COM output content of file1 to serial port
file1
CON output content of file1 to LCD
COM
file2
input data from serial port and store in file2
CON
file2
input data from keyboard and store in file2, press
[CMD]
and then
[ALPHA]
key
to end the data input
SET
This command allows users to set
system date and time, assign laser
feature and enable to display power-on logo
(see next section).
3.3 Configure the Terminal in SET command
There are three categories of general system configuration available in
SET command. Select the corresponded number, 1-3, to set system
date/time, assign scanning feature and enable power-on Logo display. Hit
[CMD] then [ALPHA] keys to return to
User mode prompt
.
3.3.1 DATE & TIME:
Setting system clock & calendar
When selects “
1.DATE & TIME
” in
SET command menu
, the screen as right
will be shown on the terminal LCD and let you set the system date and time of
Real Time Clock chip (RTC). The system date and time can be retrieved in
application and used as time stamp for data collection.
The second line shows the current date in the format YYYY/MM/DD
(year/month/day). If you want to reset the system date to January 1, 1997, then enter
[1][9][9][7],[0][1],[0][1]. Or press [ENT] key to skip the system date setting.
The third line shows the current time. The way to set system time is similar to set system date described
above. The format of system time is expressed in 24 hour of HH:MM:SS (hour:minute:second).
3.3.2 SCANNER:
The system software of terminal decodes all major bar code symboloies including Code 39, Code 128,
Codabar, Code 93, I25, EAN, UPC, China Post code, etc. Use the [
Æ
] key to toggle among selection in
each category, then press [ENT] to confirm.
SCANNER
Enable / disable bar code decoding
PEN SCAN KEY
When pen scanner is used on PT630D, user can setup whether pressing trigger
key to enable pen scanner. If
ENABLE
is selected, user must press and hold down
trigger to scan barcode label. If
DISABLE
is selected, user can directly scan
barcode label without pressing trigger key. Enable / Disable (Optional)
<SYSTEM SETUP>
1. DATE & TIME
2. SCANNER
3. DISPLAY
4. KEYPAD
5. EXIT
DATE-TIME
SETUP
1998/01/01
08:00:00
<SYSTEM SETUP>
1.DATE & TIME
2.SCANNER
3.DISPLAY
4.KEYPAD
5 EXIT