MS860 WiFi Manual
SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
Code 128
z
Enabled
toggles the ability for the scanner to read Code 128 on or
off.
Default is “No”.
z
Code ID
is a user-definable identification letter for Code 128, which
is referred to in the “Use Code ID” function on page
45
.
Default is letter “None”.
z
Minimum Length
defines the minimum length the user will accept
for a valid bar code.
Default is “1”.
z
Maximum Length
defines the maximum length the user will accept
for a valid bar code.
Default is “64”.
EAN 128
z
Enabled
toggles the ability for the scanner to read EAN 128 on or
off.
Default is “No”.
z
Code ID
is a user-definable identification letter for EAN 128, which
is referred to in the “Use Code ID” function on page
45
.
Default is letter “None”.
z
Enable Code ID
determines whether or not to assign a Code ID.
Default is “No”.
z
Field Separator
is a user-definable character to insert between
fields.
Default is “None”.
Code 32
z
Enabled
toggles the ability for the scanner to read Code 32 on or off.
Default is “No”.
z
Code ID
is a user-definable identification letter for Code 32, which
is referred to in the “Use Code ID” function on page
45
.
Default is letter “T”.
z
Send Leading Character
toggles sending or not sending a leading
(‘start bar code’) character.
Default is “Send”.
z
Send Tailing Character
toggles sending or not sending a tailing
(‘stop bar code’) character.
Default is “Send”.
51