Full ASCII Code39 

 

Enable Full ASCII Code39* 

 

Disable Full ASCII Code39 

 

 

Code39 Min/Max Length 

 

Set Min Length 

(Default = 01)

 

 

Set Max Length 

(Default = 48)

 

 

 

Example: Set Min Length as 8, Max Length as 12 for Code39 

Step1: Scan “

Set

 

Min Length

” 

Step2: Scan “

0

” “

8

” in Appendix - Numbers 

Step3: Scan “

Set

 

Min Length

” 

Step4: Scan “

Set Max Length

” 

Step5: Scan “

1

” “

2

” in Appendix - Numbers 

Step6: Scan “

Set Max Length

” 

 
Note: Configurable range for Min/Max Length is 01 ~ 99. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MS626

Page 1: ...MS626 User s Manual V1 2 MS626 2D Wireless Ring Scanner User s Manual Version 1 2 DATE 2021 12 02...

Page 2: ...C Converts to TAB ENTER ESCAPE 14 Function Code Conversion 14 Numeric Key 15 Capslock Mode 15 Keyboard Layout 16 Intercharacter Delay 18 Interblock Delay 18 BCC Binary Check Character 19 IMAGING SETTI...

Page 3: ...32 CONTINUOUS MODE 32 AUTO SENSING MODE 32 Auto sensing Mode Sensitivity 33 Continuous Auto sensing Mode Identical Read Interval 33 CHAPTER 5 DATA FORMAT 35 CODE ID 35 SET ID 35 DATA LENGTH 38 PREAMBL...

Page 4: ...nable Disable AIM 128 49 AIM 128 Min Max Length 49 CODE 39 50 Enable Disable Code 39 50 Verification 50 Start Stop 50 Full ASCII Code39 51 Code39 Min Max Length 51 CODE 32 52 Enable Disable Code 32 52...

Page 5: ...ATA 65 Enable Disable Standard 2 of 5 65 Verification 65 Standard 2 of 5 Min Max Length 66 UK PLESSEY 67 Enable Disable UK Plessey 67 Verification 67 UK Plessey Min Max Length 67 MSI PLESSEY 69 Enable...

Page 6: ...Length 77 CHAPTER 7 APPENDIX 78 APPENDIX NUMBERS 78 APPENDIX UPPER CASE ALPHABETS 79 APPENDIX LOWER CASE ALPHABETS 81 APPENDIX CONTROL CODES 83 APPENDIX SYMBOLS 85 APPENDIX FUNCTION KEYS 88 APPENDIX...

Page 7: ...experience Specifications Optic Performance Light Source White LED 625nm visible red LED Sensor 640 x 480 Scan Rate 60 Frames Sec Resolution 5mil 1D barcode 6 67mil 2D barcode Scan Angle Horizontal 4...

Page 8: ...Li Polymer Battery Number of Scan per full charge 4500 scans 1 scan 5 secs Bluetooth connected Connectivity Radio Bluetooth 5 0 dual mode Class 2 Range 66 ft 20m line of sight Interface Profile BT HID...

Page 9: ...SO 11737 1 2 Beeper Indication Beeper Status Single beep Good read Single short beep The scanner reads a Code39 ASCII during multi step configuration Two beeps Wireless connection The scanner successf...

Page 10: ...MS626 User s Manual V1 2 10 LED Indication LED Status Off Power off Standby Connected Flashing blue Disconnected Discoverable One green flash Good read Flashing red Low power Solid red Charging...

Page 11: ...s by scanning configuration barcodes in this manual Enable Barcode Configurability Disable Barcode Configurability Factory Default Scanning below configuration barcode will reset all parameters to fac...

Page 12: ...ow barcodes to determine which touch sensing button to enable according to your habit Right Button Only Left Button Only For Left handed User For Right handed User Both Button Good Read Indicator Beep...

Page 13: ...MS626 User s Manual V1 2 13 Beep Mode Normal Warning Beep Only Mute...

Page 14: ...f On HT CR ESC Converts to TAB ENTER ESCAPE Off On Note 1 By default HT I CR M and ESC A is transmitted as 0x09 0x0D and 0x1B respectively 2 When enabled HT I CR M and ESC A is transmitted as TAB ENTE...

Page 15: ...sed for trasmitting digits Scan NUMERIC KEY if you want to use the keys on the numeric keypad 2 If you select NUMERIC KEY the Num Lock status of the physical keyboard should be ON Capslock Mode Capslo...

Page 16: ...MS626 User s Manual V1 2 16 Keyboard Layout English US English UK Danish Spanish Hungarian QWERTZ Hungarian QWERTY Canadian French Dutch Italian French German Swiss German...

Page 17: ...MS626 User s Manual V1 2 17 Swiss French Swedish Czech QWERTZ Czech QWERTY Norwegian Belgian Portuguese Slovak Brazilian QWERTY Canadian Traditional Japanese Alt Code...

Page 18: ...r Delay to 8ms Step1 Scan Set Intercharacter Delay Step2 Scan 0 0 8 in Appendix Numbers Step3 Scan Set Intercharacter Delay Interblock Delay The configurable range is from 0 to 2550ms The larger the n...

Page 19: ...e The barcode data is TEST with terminator CR LF 1 BT SPP USB VCP Data Format T E S T CR LF BCC BCC 54h 45h 53h 54h 0Dh 0Ah 11h 2 BT HID USB HID Data Format T E S T Enter BCC BCC 54h 45h 53h 54h E7h F...

Page 20: ...you to enter a pincode please follow the steps in Pincode Setup section 6 The scanner will emit two beeps as indication that the Bluetooth connection has established successfully 7 While conneted with...

Page 21: ...Bluetooth application prompts you to enter a pincode please follow the steps 1 Scan Pincode Start Pincode Start 2 Scan numeric barcodes below according to the pincode generated by the Bluetooth applic...

Page 22: ...can t auto reconnect use BT SPP Master If host can auto reconnect use BT SPP Slave to avoid conflict BT SPP Master Auto reconnect BT SPP Slave No Auto reconnect 4 Select Wireless Scanner from discover...

Page 23: ...By default the pincode under BT SPP profile for the scanner is 1234 It is configurable up to 8 numbers Set SPP Pincode Example Set SPP Pincode to 0000 Step1 Scan Set SPP Pincode Step2 Scan 0 0 0 0 in...

Page 24: ...maximum of 60 minutes and 59 seconds 60 59 Set Minute Default 03 Set Second Default 00 Example Set Power Off Timeout to 5 minnutes and 30 seconds Step1 Scan Set Minute Step2 Scan 0 5 in Appendix Numbe...

Page 25: ...ID Example Set XYZ123 as Bluetooth Device ID Step 1 Scan Set Bluetooth Device ID Step 2 Scan X Y Z 1 2 3 in Appendix Upper Case Alphabets Numbers Step 3 Scan Set Bluetooth Device ID To reset Bluetoot...

Page 26: ...s a result saves user the trouble of going through numerous setup procedures on the host device to establish connection Simply generate ScanLink barcode for the target slave device in below rule For B...

Page 27: ...file BARCODE txt to your computer To exit Memory Mode simply scan any interface barcode e g BT HID BT SPP Master Slave USB HID USB VCP other than memory mode Delete Last Record To delete last memory d...

Page 28: ...xample Set Data Format as Barcode Data Date Time Step1 Scan Data Format Step2 Scan 4 3 2 respectively in Appendix Numbers Step3 Scan Data Format Field Separator The field separator in memory mode is c...

Page 29: ...de Date Format 01 DD MM YYYY 09 DD MM YYYY 02 MM DD YYYY 10 MM DD YYYY 03 DD MM YY 11 DD MM YY 04 MM DD YY 12 MM DD YY 05 YYYY MM DD 13 YYYY MM DD 06 YY MM DD 14 YY MM DD 07 DD MM 15 DD MM 08 MM DD 16...

Page 30: ...Example Set date as 2021 07 27 set time as 08 10 30 am HH MM SS Step1 Scan Set Date Step2 Scan 2 1 0 7 2 7 in Appendix Numbers Step3 Scan Set Date Step4 Scan Set Time Step5 Scan 0 8 1 0 3 0 in Appendi...

Page 31: ...Pulse Mode In Pulse Mode the LED will stay on once trigger is pressed and will not turn off until a barcode is read Pulse Mode Trigger Pulse Mode LED Auto Off Timeout The configurable range is 0 1 12...

Page 32: ...ssed and held during which the scanner will read each unique barcode once It cannot be read again until the next cycle Batch Mode Continuous Mode In Continuous Mode the LED will stay on once trigger i...

Page 33: ...step configuration Sensitivity Default 10 Example Set Sensitivity as 20 Step1 Scan Sensitivity Step2 Scan 2 0 in Appendix Numbers Step3 Scan Sensitivity Continuous Auto sensing Mode Identical Read Int...

Page 34: ...01 0 1 sec 002 0 2 sec 003 0 3 sec 004 0 4 sec 005 0 5 sec 0 6 1 sec 007 1 5 sec 008 2 0 sec 009 2 5 sec 010 3 sec 254 125 sec 255 unlimited Identical Read Interval Default 1 sec Example Set Identical...

Page 35: ...s as follows Preamble Code ID Barcode Length Barcode Data Postamble Terminator Code ID Disable Code ID Enable Factory ID Enable AIM ID Enable Set ID Set ID Set ID can be 0 2 alphanumerics for each sym...

Page 36: ...D Interleaved 2 of 5 Set ID ITF 14 Set ID ITF 6 Set ID Standard 2 of 5 Set ID Matrix 2 of 5 Set ID Industrial 2 of 5 Set ID Code11 Set ID MSI Plessey Set ID UK Plessey Set ID EAN 13 Set ID UPC A Set I...

Page 37: ...D GS1 128 Set ID AIM 128 Set ID Data Matrix Set ID GS1 Databar Set ID QR Code Set ID Micro QR Code Set ID PDF417 Set ID Data Matrix Set ID Aztec Example Set Code39 Set ID as XY Step1 Scan Set ID Code3...

Page 38: ...mble Example Set Preamble as XYZ123 Step 1 Scan Set Preamble Step 2 Scan X Y Z 1 2 3 in Appendix Upper Case Alphabets Numbers Step 3 Scan Set Preamble Postamble Postamble can be up to 16 bytes of data...

Page 39: ...MS626 User s Manual V1 2 39 Step 3 Scan Set Postamble Clear Preamble Postamble Clear Preamble Postamble Terminator None LF CR CR LF TAB Space ESC...

Page 40: ...General Settings Enable All Symbologies Disable All Symbologies Enable All 1D Symbologies Disable All 1D Symbologies Enable All 2D Symbologies Disable All 2D Symbologies Note When all symbologies are...

Page 41: ...Enable Disable UPC A Enable UPC A Disable UPC A Check Digit Send Check Digit Not Send Check Digit Lead Digit No Preamble Send System Character Country Code Send System Character Supplement 5 digit Sup...

Page 42: ...Manual V1 2 42 2 digit Supplement On 2 digit Supplement Off Supplement Required On Supplement Required Off UPC E Enable Disable UPC E Enable UPC E Disable UPC E Check Digit Send Check Digit Not Send...

Page 43: ...Lead Digit No Preamble Send System Character Country Code Send System Character Supplement 5 digit Supplement On 5 digit Supplement Off 2 digit Supplement On 2 digit Supplement Off Supplement Required...

Page 44: ...44 UPC E to UPC A Disable UPC E to UPC A Enable UPC E to UPC A EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Check Digit Not Send Check Digit Send Check Digit Supplement 5 digit Supplement On...

Page 45: ...ment On 2 digit Supplement Off Supplement Required On Supplement Required Off EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Check Digit Not Send Check Digit Send Check Digit Supplement 5 d...

Page 46: ...MS626 User s Manual V1 2 46 2 digit Supplement On 2 digit Supplement Off Supplement Required On Supplement Required Off ISBN On Off ISBN 10 ISBN 13 ISSN On Off...

Page 47: ...ength Default 01 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Se...

Page 48: ...in Length Default 01 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for GS1 128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Sca...

Page 49: ...gth Default 01 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for AIM 128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set...

Page 50: ...MS626 User s Manual V1 2 50 Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Verification Disable CDV CDV Send CD CDV Not Send CD Start Stop Not Send Start Stop Send Start Stop...

Page 51: ...Length Default 01 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code39 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan S...

Page 52: ...de 32 Enable Disable Code 32 Enable Code 32 Disable Code 32 Notw Please make sure Code39 is enabled with verification disabled before enabling Code32 Leading Tailing Send Leading Not Send Leading Send...

Page 53: ...ification Disable CDV CDV Send CD CDV Not Send CD Code 93 Min Max Length Set Min Length Default 01 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code93 Step1 Scan Set Min...

Page 54: ...umbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 55: ...Min Max Length Set Min Length Default 04 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code11 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set...

Page 56: ...Manual V1 2 56 Codabar NW 7 Enable Disable Codabar Enable Codabar Disable Codabar Verification Disable CDV CDV Send CD CDV Not Send CD Start Stop Not Send Start Stop Send Start Stop ST SP ABCD ABCD ST...

Page 57: ...Set Max Length Default 60 Example Set Min Length as 8 Max Length as 12 for Codabar Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step...

Page 58: ...MS626 User s Manual V1 2 58 Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 59: ...efault 80 Example Set Min Length as 8 Max Length as 12 for Interleaved 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Sca...

Page 60: ...Manual V1 2 60 ITF 14 Enable Disable ITF 14 Disable ITF 14 Enable ITF 14 CDV Not Send CD Enable ITF 14 CDV Send CD ITF 6 Enable Disable ITF 14 Disable ITF 6 Enable ITF 6 CDV Not Send CD Enable ITF 6...

Page 61: ...MS626 User s Manual V1 2 61 Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 62: ...efault 80 Example Set Min Length as 8 Max Length as 12 for Matrix 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2...

Page 63: ...MS626 User s Manual V1 2 63 Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Industrial 2 of 5 Disable Industrial 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 64: ...efault 48 Example Set Min Length as 8 Max Length as 12 for Industrial 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan...

Page 65: ...MS626 User s Manual V1 2 65 Standard 2 of 5 IATA Enable Disable Standard 2 of 5 Enable Standard 2 of 5 Disable Standard 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 66: ...efault 48 Example Set Min Length as 8 Max Length as 12 for Standard 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1...

Page 67: ...erification Disable CDV CDV Send CD CDV Not Send CD UK Plessey Min Max Length Set Min Length Default 04 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for UK Plessey Step1 Scan...

Page 68: ...MS626 User s Manual V1 2 68 Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99...

Page 69: ...1 2 69 MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Verification Disable CDV CDV Send CD CDV Not Send CD Check Digit Single Digit MOD10 Double Digits MOD10 MOD10 Doubl...

Page 70: ...efault 48 Example Set Min Length as 8 Max Length as 12 for MSI Plessey Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 i...

Page 71: ...Manual V1 2 71 GS1 DataBar RSS 14 Enable Disable GS1 DataBar Enable GS1 DataBar Disable GS1 DataBar Prefix AI Send Prefix AI 01 Not Send Prefix AI 01 QR Code Enable Disable QR Code Enable QR Code Dis...

Page 72: ...Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 0 0 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 0001 4000 QR Twin Code QR twin code...

Page 73: ...Set Min Length Default 01 Set Max Length Default 35 Example Set Min Length as 8 Max Length as 12 for Micro QR Code Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Leng...

Page 74: ...n Set Min Length Step2 Scan 0 0 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 0 0 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for...

Page 75: ...MS626 User s Manual V1 2 75 Single Data Matrix Only Twin Data Matrix Only Both Single Twin Rectangular Barcode Enable Disable PDF417 Enable Disable PDF417 Enable PDF417 Disable PDF417...

Page 76: ...can Set Min Length Step4 Scan Set Max Length Step5 Scan 0 0 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 0001 2750 PDF417 Twin Code PDF417 twin code...

Page 77: ...0001 Set Max Length Default 4000 Example Set Min Length as 8 Max Length as 12 for Aztec Step1 Scan Set Min Length Step2 Scan 0 0 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Le...

Page 78: ...MS626 User s Manual V1 2 78 Chapter 7 Appendix Appendix Numbers 0 1 2 3 4 5 6 7 8 9...

Page 79: ...MS626 User s Manual V1 2 79 Appendix Upper Case Alphabets A B C D E F G H I J K L M N O P...

Page 80: ...MS626 User s Manual V1 2 80 Q R S T U V W X Y Z...

Page 81: ...MS626 User s Manual V1 2 81 Appendix Lower Case Alphabets a b c d e f g h i j k l m n o p...

Page 82: ...MS626 User s Manual V1 2 82 q r s t u v w x y z...

Page 83: ...MS626 User s Manual V1 2 83 Appendix Control Codes NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI...

Page 84: ...MS626 User s Manual V1 2 84 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US...

Page 85: ...MS626 User s Manual V1 2 85 Appendix Symbols _...

Page 86: ...MS626 User s Manual V1 2 86...

Page 87: ...MS626 User s Manual V1 2 87 SP DEL...

Page 88: ...MS626 User s Manual V1 2 88 Appendix Function Keys F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Home End Enter Numeric Key App...

Page 89: ...MS626 User s Manual V1 2 89 Appendix Navigation Keys Cursor Left Cursor Right Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter BS Ins Del...

Page 90: ...1 2 90 Appendix Modifier Keys Alt Left make 1 Alt Left break Alt Right make Alt Right break Shift Left make 2 Shift Left break Shift Right make Shift Right break Win Left make Win Left break Win Right...

Page 91: ...sume barcode setting 2 When Shift Left make is programmed please scan Shift Left break to resume barcode setting 3 When Ctrl Left make is programmed please scan Ctrl Left break to resume barcode setti...

Page 92: ...N Numeric Key OFF Capital Lock Mode OFF Keyboard Layout English US Intercharacter Delay 10ms Interblock Delay 0ms BCC OFF Image Settings Inverse Barcode OFF Interface BT HID Getting Connected N A BT S...

Page 93: ...Data Format Code ID Disable Set ID N A Data Length OFF Preamble N A Postamble N A Terminator CR Symbologies General Settings N A UPC A Enable Disable ON Check Digit Send Lead Digit No Preamble Supplem...

Page 94: ...8 UCC EAN 128 Enable Disable ON Min Length 01 Max Length 48 AIM 128 Enable Disable OFF Min Length 01 Max Length 48 Code 39 Enable Disable ON Verification Disable CDV Start Stop Not Send Full ASCII Cod...

Page 95: ...e ON Verification Disable CDV Min Length 06 Max Length 80 ITF 14 Enable Disable OFF ITF 6 Enable Disable OFF Matrix 2 of 5 Enable Disable ON Verification Disable CDV Min Length 04 Max Length 80 Indust...

Page 96: ...ble ON Min Length 0001 Max Length 4000 QR Twin Code Single QR Code Only Micro QR Code Enable Disable ON Min Length 01 Max Length 35 Data Matrix Enable Disable ON Min Length 0001 Max Length 3116 Data M...

Page 97: ...6 Code 128 K 4B 7 GS1 128 T 54 8 AIM 128 q 71 9 Code 39 M 4D 10 Full ASCII Code 39 D 44 11 Code 32 B 42 12 Code 93 L 4C 13 Code 11 J 4A 14 Codabar N 4E 15 Interleaved 2 of 5 ITF 14 I 49 16 Matrix 2 o...

Page 98: ...MS626 User s Manual V1 2 98 23 Data Matrix X 58 24 QR Code W 57 25 Micro QR Code w 77 26 Aztec z 7A 27 ITF 6 6 36...

Page 99: ...3 4 EAN 13 E0 5 EAN 13 with Addon E3 6 UPC E E0 7 UPC E with Addon E3 8 UPC A E0 9 UPC A with Addon E3 10 Interleaved 2 of 5 lm 0 1 3 11 ITF 14 lm 1 3 12 ITF 6 lm 1 3 13 Matrix 2 of 5 X0 14 Code 39 Co...

Page 100: ...QR Code Qm 0 6 28 Aztec zm 0 29 Data Matrix dm 0 6 30 Micro QR Q1 Note m represents the AIM modifier character Refer to ISO IEC 15424 2008 Information technology Automatic identification and data cap...

Page 101: ...Line Feed 0B 11 VT Vertical Tab 0C 12 FF Form Feed 0D 13 CR Carriage Return 0E 14 SO Shift Out 0F 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13...

Page 102: ...nthesis 2A 42 Asterisk 2B 43 Plus 2C 44 Comma 2D 45 Minus Dash 2E 46 Dot 2F 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3A 58 Colon 3B 59 Semi colo...

Page 103: ...57 87 W 58 88 X 59 89 Y 5A 90 Z 5B 91 Left Opening Bracket 5C 92 Back Slash 5D 93 Right Closing Bracket 5E 94 Caret Circumflex 5F 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 6...

Page 104: ...626 User s Manual V1 2 104 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7A 122 z 7B 123 Left Opening Brace 7C 124 Vertical Bar 7D 125 Right Closing Brace 7E 126 Tilde 7F 127 DEL Dele...

Page 105: ...r s Manual V1 2 105 Version History Rev Date Description Issued 1 0 2021 07 28 Initial Release Shaw 1 1 2021 10 12 Updated Product Picture Shaw 1 2 2021 12 02 Updated Range to 66ft 20m EMC RF with CE...

Reviews: