background image

Note: 1. See user manuals for more information. 2. For better readability, please print this document with laser printer. 3. Version: MS351QGENV1.2.

MS351 Cordless Scanner Quick Guide

Notice

Parts of the scanner

Scan window

Trigger (Press to triggr / Long press 10 seconds to turn on)

Beeper

On Base indicator (Blue LED)

Successful decoding indicator (Green LED) /

Communication fail indicator (Red LED) / Charging (Red/Greed LED)

Parts of the cradle

Power indicator (Blue LED)

Communication indicator (Green LED)

Key (Long press 10 seconds to restore factory default setting of

cradle)

Installation of cradle

1. Switch off power of the host. Refer to the below pictures, connect the host with the scanner with different

cables firstly, and then connect the adaptor to the power socket.

2. Ensure that all connections are secure. Switch on the power of the host. After a few seconds, if only the

blue LED on the cradle is ON, it indicates the cradle is in normal working mode.

USB cable

RS232 cable

PS/2 keyboard cable

Charge battery

1. Please charge the battery before the first time use.

The charge

indicator (Red LED) on the scanner is turned on when the charging is
in progress.

When the charging process completes, the charge

indicator (Red LED) is turned off, and the Green LED is turned on.

2. Charging time: 4 hours for fully charged.
3. You can charge the battery via a USB port on the device or an optional

5 VDC adapter.

Indication of scanner for wireless data transmission

Successful

Transmission

Beeper

Red LED

Vibration

Yes

Off

Off

Off

No

Two long beeps

Blinks 2 times, and then

turns off

Short vibrates 2 times, and

then turns off

Programming instruction and example

Two programming modes have been provided as bellows:

Single-scan setting

Scan the related

Single-scan setting

Example: To set Flow control to be XON/XOFF.

Multiple-scan setting

Example: To set Flow control to be XON/XOFF.

1.

Turn off/on handheld unit

1. If you want to turn off the scanner, scan the barcode as shown right.
2. If you want to turn off the scanner via trigger key, please press and hold the trigger key, after the laser beam
turns off, wait for another 5 seconds, the scanner will be turned off, then you can release the trigger key at this
moment.
3. If you want to turn on the scanner again, please keep the trigger key being pressing for 3 seconds.

A standard kit contains: a scanner, a cradle, a USB cable, and a CD-ROM (containing software and manuals).

It is suggested to read the user manual in details before use.

Reviews: