S
CANNER
O
PERATION
Miscellaneous Decode Features
³
1
1
8
1
1
3
* Optional Same Symbol Check
- Requires 1
different character between successive bar codes
to consider the bar code “new”.
³
1
1
8
1
0
3
Normal Same Symbol Check
- Requires 3
different characters between successive bar codes
to consider the bar code “new”.
Same Symbol Time Outs
The length of time before a bar code can be rescanned after it is removed from
the scan field is user-configurable in increments of 50 msecs to 6350 msecs
(6.35 sec).
³
9
1
8
9
0
0
~ Variable Same Symbol Time Out
- In configuration
mode, scan this bar code followed by the appropriate
code byte sequence to set the same symbol time out
duration.
³
8
1
8
9
0
0
No Same Symbol Time Out
³
1
1
8
9
1
7
Infinite Same Symbol Time Out
- The scanner will
not repetitively scan the same bar code. This
option overrides the symbol rescan time-outs.
LED Options
³
1
1
8
3
1
3
Flash Green LED if Rescan Allowed
- This
indicates same symbol timeout has elapsed.
³
1
1
8
3
0
3
* Do Not Flash Green LED if Rescan Allowed
³
1
1
8
3
1
2
Reverse LED Functions
- Red = Laser On
Green = Good Read
³
1
1
8
3
0
2
* Normal LED Functions
- Green = Laser On
Red = Good Read
5