4-51
identification entry in the TERM_CONFIG table must be terminated
by a character, ASCII_Z (hex 0), as in C language convention.
online:
'
R
'
= set to Remote and transmit data to the
host port (default)
'L'
= set to Local and do not transmit
echo:
'
N
'
= set to Echo and transmit displayed data to
the host port
'F'
= do not transmit
The above two variables, TERM_online and
TERM_echo, are used to control transmission and
display of the collected data, respectively. If
TERM_online is set to
Remote
the MR350MKII will
transmit data to the host, otherwise it will not
transmit. If TERM_echo is set to
Echo
collected data
will be displayed on the MR350MKII LCD,
otherwise data will not be displayed.
autolf:
'N'
= set not to append a LF after a CR
'
F
'
= set to append a LF (default)
This variable instructs the MR350MKII to append a
LF character whenever a CR is collected from an
input scanning device.
mode:
'C'
= set to Character mode
'
B
'
= set to Block mode (default)
This parameter specifies either character mode or
block mode free-format operation. The
aforementioned form caching operation is only
applicable when the MR350MKII is set in block
mode.
linepage:
'
L
'
= set line block mode (default)
'P'
= set page block mode
'B'
= set both line and page block modes
The
linepage
parameter is useful only if
mode
has
been specified as 'B'.
lineterm:
designates the termination character of line
block mode (default = null)
pageterm:
designates the termination character of page
block mode (default = null)