pu8FirmwareVer);
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)
pu8SerialNum: Get reader’s serial number (Length: READER_SERIAL_LEN)
pu8FirmwareVer: Get reader’s firmware version (Length: FIRMWARE_VER_LEN)
Return code:
Please refer to section 9.10.
9.5. Antenna
Control
Function Description:
Enable/Disable antenna to save power.
Function Call:
INT32 RDINTv2_AntennaControl (BYTE u8COMPort, BYTE u1OnOff);
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)
u1OnOff: TURN_ON
TURN_OFF
Return code:
Please refer to section 9.10.
9.6. Close
Reader
Function Description:
To finish controlling the reader.
Function Call:
INT32 RDINTsys_CloseReader (BYTE u8COMPort);
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)
Return code:
Please refer to chapter 9.10.
9.7. Set ISO-15693 Inventory Parameter
Function Description:
Set inventory parameter for ISO-15693.
Function Call:
INT32 RDINT_ISO15693AutoInventoryParam (BYTE u8COMPort, BYTE u8Flag, BYTE u8Afi,
BYTE u8MaskLen, LPBYTE pu8Mask);
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)
u8Flag:
It specifies the actions to be performed by the VICC and whether
corresponding fields are present or not.
u8Afi:
Application Family Identifier parameter.
u8MaskLen:
The mask length indicates the number of significant bits of the mask value.
It can have any value between 0 and 60 when 16 slots are used and any
value between 0 and 64 when 1 slot is used. LSB shall be transmitted first.
pu8Mask:
The mask value is contained in an integer number of bytes. LSB shall be
transmitted first.
Return code:
Please refer to section 9.10.
9.8. ISO-15693
Inventory
Function Description:
Read ISO-15693 Tag.
Function Call:
INT32 RDINT_ISO15693AutoInventory4Antennas (BYTE u8COMPort, LPBYTE pu8GRLUid);
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)