![background image](http://html1.mh-extra.com/html/unitec/ds-205-4/ds-205-4_manual_3978825015.webp)
14
DS 205.3 ; DS403.4
A
ss
e
m
b
ly
Assembty notice:
Recommended DIN 912 M4x12 fixing bolt with
lock washer.
Place M4 tap holes at a vertical distance of
312mm.
Drilling template in appendix.
Fix M4x12 screws.
Distance to rear wall of control cabinet approx.
4mm.
Position device with the top edge (1).
Slide it upwards to stop (2).
Press its bottom up to rear wall of control
cabinet (3)
and lower it (4).
Tighten screws.
For good EMC values we recommend blank metal, unvarnished mounting bases. Good
surface contact is achieved by the blank metal rear wall of the device. Lay signal lines and
power cables in separate cable channels, cross them at right angles.
(Spacial separation of interference coupling).