TABLE 10 -
SUPERHEAT CHARGING TABLE FOR MODEL DAPH042
OUTDOOR
TEMPERATURE
(F)
SUPERHEAT AT COMPRESSOR SUCTION (F), AIRFLOW = 400 CFM/TON
INDOOR WB TEMPERATURE (F)
55
57
59
61
63
65
67
69
71
73
75
65
24.9
25.4
26.0
26.6
27.2
27.8
28.3
28.6
28.9
29.2
29.5
70
21.6
22.3
23.0
23.7
24.3
25.0
25.7
26.4
27.2
28.0
28.7
75
18.4
19.2
19.9
20.7
21.5
22.3
23.0
24.2
25.5
26.7
27.9
80
15.2
16.0
16.9
17.8
18.6
19.5
20.4
22.0
23.7
25.4
27.1
85
12.0
12.9
13.9
14.8
15.8
16.8
17.7
19.8
22.0
24.1
26.3
90
7.9
8.8
9.8
10.7
11.7
12.7
13.6
16.8
19.9
23.1
26.3
95
-
-
5.7
6.6
7.6
8.6
9.5
13.7
17.9
22.1
26.3
100
-
-
-
5.6
6.4
7.2
8.0
11.7
15.4
19.1
22.8
105
-
-
-
-
5.3
5.9
6.6
9.8
12.9
16.1
19.3
110
-
-
-
-
-
-
5.1
7.8
10.5
13.1
15.8
115
-
-
-
-
-
-
-
5.8
8.0
10.2
12.3
TABLE 11 -
SUPERHEAT CHARGING TABLE FOR MODEL DAPH048
OUTDOOR
TEMPERATURE
(F)
SUPERHEAT AT COMPRESSOR SUCTION (F), AIRFLOW = 400 CFM/TON
INDOOR WB TEMPERATURE (F)
55
57
59
61
63
65
67
69
71
73
75
65
27.6
27.8
28.0
28.1
28.3
28.5
28.7
29.2
29.1
30.3
30.8
70
23.3
223.8
24.3
24.8
25.4
25.9
26.4
27.2
28.0
28.8
29.6
75
19.0
19.8
20.7
21.5
22.4
23.3
24.1
25.2
26.2
27.3
28.3
80
14.7
15.9
17.0
18.2
19.4
20.6
21.4
23.1
24.5
25.8
2.1
85
10.4
11.9
13.4
14.9
16.5
18.0
19.5
21.1
22.7
24.3
25.9
90
6.8
8.3
9.8
11.3
12.9
14.4
15.9
18.2
20.4
22.7
25.0
95
-
-
6.3
7.8
9.2
10.7
12.2
15.2
18.4
21.2
24.2
100
-
-
5.1
6..4
7.7
8.9
10.2
12.7
15.1
17.6
20.0
105
-
-
-
5.0
6.1
7.2
8.2
10.1
12.0
13.9
15.8
110
-
-
-
-
-
5.4
6.3
7.6
8.9
10.3
11.6
115
-
-
-
-
-
-
-
5.1
5.9
6.6
7.4
530.46-N2Z
8
Unitary Products Group