Note:
To prevent repetitive temperature alarming, there is a
0.9 °F(0.5
°C
) tolerance band. For example, if you set the high
alarm to 80.0°F(26.7
°C
) and silence the alarm, the alarm icon
will continue to flash until the temperature falls below 80.0°F
(26.7
°C
), at which point, the alarm will reset and must increase
above 80.0°F(26.7
°C
) to activate again.
Note:
To prevent repetitive alarming of humidity, there is a
4% tolerance band in humidity alarm. For example, if you set
the high alarm to 60% and silence the alarm, the alarm icon will
continue to flash until the humidity falls below 56%, at which
point, the alarm will reset and must increase above 60% to
activate again.
8.4 Alarm and Key Beeper ON/OFF
Press any button to silence the alarm sound.
19.
Relative pressure HI alarm
20.Relative pressure low alarm
21.Indoor temperature HI alarm
22.Indoor temperature low alarm
23.Indoor humidity HI alarm
24.Indoor humidity low alarm