NX5820 K Product Configurations
7017 6300–005
2–15
Table 2–6. ClearPath Enterprise Server NX5820 K Product Models
Model
(Performance
Level)
Processor
Modules
Memory
Storage
Units
1
CIOM
Modules
2
Std/Max
Servers
3
Std/Max
System
(SCP)
Console
Std/Max
SCSI-2W
Channels
4
802.3
Channels
Maint
LAN
Channel
Maint
Hub
Std/Max
Switching
Hub
5
Std/Max
NX5822-BAS
NX5822-2D7
(with NX5827-PL7)
7
4/6
2/12
1/10
1/2
4
2
2
1/2
1/Unlimited
NX5822-BAS
NX5822-2D8
(with NX5828-PL7)
8
4/6
2/12
1/10
1/2
4
2
2
1/2
1/Unlimited
NX5822-BAS
NX5822-2DA
(with NX58210-PL7)
10
4/6
2/12
1/10
1/2
4
2
2
1/2
1/Unlimited
Notes:
1.
The NX5820 K utilizes two styles of memory boards (MSA and MSK). The MSA104 boards are to be
configured in all systems up to and including models NX5821-1D1 and NX5822-2D2. The MSK208 boards
are to be configured in system models NX5822-2D3 to -2D6. The MSK412
boards are to be
configured in models NX5822-2D7, NX5822-2D8 and -2DA.
2.
Up to five CIOMs can be configured per domain to provide CS-Bus connectivity. Optional one CIOM in
domain 0 is dedicated for Multi IOU functionality and one CIOM in domain 1 is dedicated for TCU
functionality. These can not be used for CS-Bus connectivity.
3.
Each model includes a basic server; up to five servers per domain are configurable.
4.
Dedicated SCSI-2W channels (2 per domain)for connection of OSS7000 device (QIC tape, CD-ROM, and
hard disk).
5.
Space provided for two switching Hubs within CEC cabinet, additional hubs can be configured as
required.
NX5820 K Product Configurations
This subsection describes the NX5820 K product configurations.
ClearPath Enterprise Server NX5821–BAS Single-Domain, Single-
Processor (SDSP) Configurations
•
Table 2–7 lists component styles for these models.
•
Figure 2–5 and Figure 2–6 show the hardware configurations for system cabinets
containing VX1305- and VX1505-based servers, respectively.
•
Processor styles are listed later in this section.
•
Power/cooling options are listed later in this section.
•
System upgrades are listed later in this section.
•
Section 3 provides guidelines for adding system options.
Summary of Contents for NX5820 K
Page 4: ...Format these characters as white to force printing of blank page...
Page 8: ...Format these characters as white to force printing of blank page...
Page 162: ...Configuring Optional and Recommended UPS 6 56 7017 6300 005...
Page 164: ...Connecting Other Host Systems 7 2 7017 6300 005...
Page 169: ...Glossary 7017 6300 005 Glossary 5 U UPS Uninterruptible power supply USD Unity storage device...
Page 170: ...Glossary Glossary 6 7017 6300 005...
Page 175: ......
Page 176: ...70176300 005 7 0 1 7 6 3 0 0 0 0 5...