Page 10
655920
Electra Steer Diagnosis Trouble Code Reading and Code Clearing
1. Verify that your trouble code light is on steady.
2. Next, take your purple or brown wire and connect it to a good clean ground. You
will have to make sure it is a solid ground to get the LED to blink or flicker and
you may have to use a jumper wire to extend the wire’s length. Once you see the
LED flicker or blink wait for LED to start blinking a code.
3. The light will flash in a sequence like 1 and then 123. This code flash would be
interpreted as a code 13. The code will repeat itself 3 times and then go to the next
code if there is one in the system. You need to wait until all the codes are read and
recorded.
4. Once you know what the codes are you can use this chart to tell where or what the
problem may be.
5. Once you have determined what the problem is and make the necessary repairs,
you can proceed to clear the codes by running a jumper wire from the white wire
with the single spade connector on it to ground.
6. Verify the ignition is off. Place the white wire to ground. Turn key on, wait 5
seconds and the light should go out. When the light goes out turn off ignition and
remove jumper wire. Once all repairs are made turn ignition on and see that light
proves out normally. This is all there is to it.
Trouble Code
Problem
Diagnosis
41-42-43-44-
Electric motor
Change Electric
45-51
Malfunction
Motor
11-13-14-15
Torque Sensor
Change Sensor
52-54-55
ECU
Change
Malfunction
Computer
22
No Engine
Computer Error
Input
21-23-24
No Speed
Computer Error
Signal
We welcome your suggestions & comments to make this or any of our installations better! If
you have any questions or problems regarding this product please contact us at:
1555 Enterprise Parkway
Twinsburg OH 44087
800-338-9080
WWW.UNISTEER.COM
655920
(1/9/09)
Copyright © 2009 by Maval Manufacturing Corporation All rights reserved.
No part of these materials can be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying, recording or by any information storage
and retrieval system, without permission in writing from Maval Manufacturing Corporation.