Operation manual of solar water controller SR601
--------------------------------------------------------------------------------------------------
~ 15 ~
necessary to set every day.
During the water loading process, press “Timing load” button again, it
can stop the water loading immediately.
When the symbol" " light on screen,"Timing load" function is
activated.
5.5 Temperature control water loading
Functional description:
When this function is activated, water will be loaded according to preset
loading temperature. In
the case that water tank isn’t full, when tank
temperature is above the preset loading temperature, controller starts to
load water automatically until tank temperature drops to 5
o
C
below the
loading temperature. In the case that water level is changed in the same,
then water loading will be started after 60 minutes, doing like this can
avoid water temperature changes so acutely and therefore avoid
uncomfortable feeling for customer.
Press "tem. Load" button continuously to adjust the desired temperature
for triggering water loading, adjustable range is "35
o
C
~95
o
C"
, default
value is 55
o
C
, 3 seconds later controller confirms the setting. The
indicating light of temperature controlled water loading is on. When the
water temperature is higher than the preset temperature of tank, water
loading is started, when the water temperature drops 5
o
C
below the
preset temperature, water loading is stopped. Press this button again to
cancel this mode.
When the symbol" " light on screen,"Tem.Load" function is activated.
5.6 Hot water circulation
Function description:
The controller support the function that time-controlled hot water circuit