background image

                                                                                                                              Unison Research

  

Unico Primo    

 

13 

3.

 

CONNECTION TO THE MAINS 

 

The 

Unico  Primo

  is  set  at  the  factory  to  the  appropriate  mains 

voltage of the country it will be shipped to.  

 

IMPORTANT! 

The voltage setting may not be changed. 

Never connect the 

Unico Primo

 to AC mains if the local voltage 

doesn’t match the value indicated on the rear panel!   

The  mains  fuse  is  located  in  the  fuse-holder  integrated  in  the  IEC 

mains socket.

  

 

IMPORTANT!  

Always replace fuses with new ones of the same 

type and value.

 

 

 

4.

 

OPERATION 

 

SWITCHING-ON AND WARM-UP 

 

WARNING! 

Switch  on  the 

Unico  Primo

  only  after  all  the 

connections have been made and checked. 

 

Before switching on, ensure that the volume control is at zero (fully 

anti-clockwise),  and  allow  it  to  remain  in  that  position  until  the 

initial automatic start-up phase is complete. 

 

Just after switching on 

Unico Primo

 automatically starts a 

warm-up

 

phase,  the  LEDs  placed  on  the  front panel near the input selection 

and  volume  knobs  blink.  In  this  status  output  stages  are  disabled, 

however with an input source a weak signal can be heard through the 

loudspeakers. 

 

The  working  temperature  for  the  tubes  is  reached  less  than  30 

seconds  after  switching  on  but  best  results  will  be  obtained  after 

approximately 10 minutes  from switch-on.

  

 

 

Summary of Contents for Unico Primo

Page 1: ...HIGH END ELECTRONICS BORN IN ITALY...

Page 2: ......

Page 3: ...are pezzi esclusivi di grande valore in cui la tradizionale abilit artigiana si unisce e si integra con un alta tecnologia elettronica Ogni nostro prodotto viene realizzato con materiali e componenti...

Page 4: ...ecchio Tale condensa potrebbe formarsi anche spostando l unit da un ambiente freddo ad uno caldo anche in questo caso occorre attendere alcune ore in modo che l apparecchio possa adattarsi alla nuova...

Page 5: ...tutte le connessioni sono state verificate Prima di accendere l apparecchio assicurateVi che la manopola del volume sia posizionata sul minimo e che resti in tale stato fintantoch terminata la pre acc...

Page 6: ...SELETTORE 2 LED INPUT 3 MANOPOLA VOLUME 4 LED VOLUME 5 SENSORE RICEVITORE IR 6 INTERRUTORE PRINCIPALE SUL FIANCO PANNELLO POSTERIORE 1 PRESA RETE 2 MORSETTI DI USCITA 3 INGRESSI E USCITE LINEA 4 VITE...

Page 7: ...ich riparte automaticamente ripetendo la fase di pre accensione Si consiglia comunque lo spegnimento dell amplificatore questa operazione consente infatti un pi rapido ripristino delle normali condizi...

Page 8: ...uadagno degli stadi di 10dB in modo tale che il livello di amplificazione sia il pi indicato possibile in funzione della testina usata In pratica con testine di tipo MM aventi tensioni di uscita infer...

Page 9: ...ituire la valvola esclusivamente con altra dello stesso tipo selezionata ad hoc L apparecchio utilizza una valvola di tipo ECC83 12AX7 La progettazione elettronica stata fatta per assicurare una lunga...

Page 10: ...8...

Page 11: ...T in coppia complementare Ingressi 5 linea RCA 1 phono optional Uscite linea 1 tape 1 sub con controllo di volume Connessioni di uscita 4 4 bi wiring Fattore di retroazione 10dB THD 0 15 1kHz 10W Asso...

Page 12: ...10...

Page 13: ...lso express our passion for building unique and valuable pieces of audio equipment in which traditional craftsmanship and advanced electronics join together in harmony Our products are built using the...

Page 14: ...y possible damage due to the condensation which can eventually form during transportation Please note that condensation can form every time the amplifier is moved from a cold to a warm place Keep all...

Page 15: ...WARNING Switch on the Unico Primo only after all the connections have been made and checked Before switching on ensure that the volume control is at zero fully anti clockwise and allow it to remain in...

Page 16: ...SELECTOR KNOB 2 INPUT LED 3 VOLUME KNOB 4 VOLUME LED 5 IR RECEIVER 6 MAIN SWITCH ON THE SIDE REAR PANEL 1 MAINS PLUG 2 OUTPUT CONNECTORS 3 LINE LEVEL INPUT AND OUTPUT CONNECTORS 4 GROUND CONNECTION 1...

Page 17: ...repeat the initial start up phase It is advisable to switch off if the amplifier if the thermal protection device intervenes This will speed up return to normal operation INPUT LED on and VOLUME LED...

Page 18: ...adjustment to be carried out The relative positions are clearly marked MM and MC Two further movable links fitted to the phono board allow the level of gain amplification to be changed by 10dB In pra...

Page 19: ...the amplifier is in the OFF position Valve replacement should be carried out using only valves of the same type and matched in pairs The Unico Primo uses one valve type ECC83 12AX7 The amplifier has...

Page 20: ...18...

Page 21: ...POWER MOSFET in complementary pair Inputs 5 line RCA 1 phono optional Line outputs 1 tape 1 sub volume controlled Output connectors 4 4 bi wiring Feedback factor 10dB THD 0 15 1kHz 10W Power consumpti...

Page 22: ...f radio disturbance characteristics of broadcast receivers and associated equipment EN 61000 3 2 1995 and subsequent modifications Electromagnetic compatibility Part3 Limits Section 2 Limits for harmo...

Page 23: ...Sicurezza e manutenzione pag 7 9 Caratteristiche tecniche pag 9 User Manual pag 11 1 Unpacking pag 12 2 Installation pag 13 3 Connection to the mains pag 13 4 Operation pag 14 5 Fuses pag 16 6 Safety...

Page 24: ...2002 95 CE 2002 96 CE oraz 2003 108 CE Unii Europejskiej dotycz cymi zredukowania u ycia niebezpiecznych substancji w sprz cie elektrycznym oraz elektronicznym a tak e utylizacji odpad w Produkty lub...

Page 25: ...IL FORBRUKER I overensstemmelse med EC direktivene 2002 95 CE 2002 96 CE og 2003 108 CE ang ende reduksjon av bruken av farlige stoffer i elektrisk og elektronisk utstyr og avskaffelse av defekte prod...

Reviews: