background image

                                                                                                                                                          Unison Research

  

Unico Due 

 

18 

5.

 

OPERATING THE UNICO DUE 

 

INPUT SELECTOR 

You can select the desired input source by rotating the 
knob named “selector” or pressing the corresponding 
buttons on the remote handset. The  selection 
sequence  is  cyclic;  the  selected  input  is indicated 
by the front panel LEDs. 

 

 

ADJUSTING THE 
VOLUME 

The volume level can be adjusted by rotating the 
“volume” knob or pressing the corresponding buttons 
on the remote handset; the level is indicated on the 
front panel display which shows a number between 0.0 
(minimum) and 9.9 (maximum). 

 

 

TAPE/MONITOR 

Selecting  tape/monitor  makes another  line-level 
input available (see Notes  about inputs);  it is selected 
with a brief press of the selector knob. Another short 
press returns the unit to the previously selected input. 

 

 

MUTE 

The mute function immediately sets the volume level 
to minimum. Pressing the volume knob toggles the 
mute on or off. The level shown on the display doesn’t 
change but the mute condition is indicated by the 
status LEDs. Disengaging mute returns volume to the 
previous level. 

 

 

OSD 

The OSD function sets the output power stages to 
stand-by mode, leaving the input and valve stages in 
function.  
When the OSD function is disengaged, the unit returns 
to normal working mode without any warm up delay. 
The DAC line output is always active. 

 

 

DISPLAY OFF 

When the display is set to off, the LED display turns 
off after 20 seconds of inactivity and turns on 
automatically when any function is activated. 

 

Summary of Contents for Unico Due

Page 1: ...Unico Due...

Page 2: ......

Page 3: ...realizzare pezzi esclusivi di grande valore in cui la tradizionale abilit artigiana si unisce e si integra con un alta tecnologia elettronica Ogni nostro prodotto viene realizzato con materiali e comp...

Page 4: ...i alla nuova temperatura prima di metterlo in funzione Conservate l imballo intatto vi servir nel caso in cui doveste riutilizzarlo e contribuirete cos alla tutela dell ambiente 2 INSTALLAZIONE L Unic...

Page 5: ...e entra in una fase di warm up durante la quale sul display viene visualizzato un conto alla rovescia riportante i secondi che mancano alla fine della fase di riscaldamento Durante questo intervallo l...

Page 6: ...on Research Unico Due 4 PANNELLO FRONTALE 1 MANOPOLA SELETTORE 2 LED DI STATO 3 PULSANTE OSD 4 DISPLAY DUE CIFRE 5 MANOPOLA VOLUME 6 PULSANTE DISPLAY OFF 7 INTERRUTORE PRINCIPALE SUL FIANCO 1 2 3 4 7...

Page 7: ...Unison Research Unico Due 5 PANNELLO POSTERIORE 1 PRESA RETE 2 INGRESSO DAC USB 3 MORSETTI DI USCITA 4 INGRESSI E USCITE DI LINEA 1 2 3 4...

Page 8: ...ione alla manopola del selettore Un ulteriore pressione permette di ritornare all ingresso selezionato MUTING La funzione di muting applica istantaneamente la massima attenuazione del segnale di ingre...

Page 9: ...elecomando Unico Due commuter sull ingresso AV prescelto settando il volume al livello che avete impostato Impostazione funzione AV Selezionare il canale e il volume desiderato tramite le manopole del...

Page 10: ...di resistenze di precisione integrate e selezionabili al fine di fornire il livello di attenuazione desiderato nello stesso package implementato uno stadio di uscita attivo in grado di fornire un liv...

Page 11: ...eguire la sostituzione da un centro assistenza qualificato Pulizia dell apparecchio La pulizia dell apparecchio va eseguita ad apparecchio spento Utilizzate un panno morbido ed asciutto Non usate solv...

Page 12: ...atteria di tipo CR2032 3V batteria al litio 9 FUSIBILI Internamente all apparecchio sono collocati sei fusibili Scheda CT F3 F6 1AT 250V Mainboard F3 F4 1 6AT 250V F1 F2 6 3AT 250V Sulla presa di rete...

Page 13: ...si 3 di linea 1 USB 1 monitor Uscite di linea 1 tape 1 DAC 1 sub controllato dal volume Output connectors 4 4 bi wiring THD 0 25 1kHz 10W Power Consumption 360W at max power on 8 ohm Dimensions 43 5 c...

Page 14: ...chio 6 6 Funzioni speciali 7 7 Note sugli ingressi 8 8 Sicurezza e Manutenzione 9 9 Fusibili 10 10 Caratteristiche tecniche 11 Unison Research marchio registrato di A R I A Advanced Research In Audio...

Page 15: ...y Each one of our products is the fruit of our passion for building unique and valuable pieces of audio equipment in which traditional craftsmanship and advanced electronics join together in harmony U...

Page 16: ...arton will provide the safest packing 2 INSTALLATION The Unico Due should be positioned in a safe place on a flat surface out of reach of children Adequate clearance at least 5cm must be left above an...

Page 17: ...up phase During this phase a counter on the display on the front panel counts down showing the time remaining until the end of the warm up phase The output stages are disabled and the unit is in mute...

Page 18: ...Unison Research Unico Due 16 FRONT PANEL 1 INPUT SELECTOR KNOB 2 STATUS LEDS 3 OSD BUTTON 4 DOUBLE DIGIT DISPLAY 5 VOLUME KNOB 6 DISPLAY OFF BUTTON 7 MAINS SWITCH ON THE SIDE 1 2 3 4 7 6 5...

Page 19: ...Unison Research Unico Due 17 REAR PANEL 1 MAINS SOCKET 2 USB DAC INPUT 3 SPEAKER TERMINALS 4 LINE INPUTS AND OUTPUTs 1 2 3 4...

Page 20: ...tes about inputs it is selected with a brief press of the selector knob Another short press returns the unit to the previously selected input MUTE The mute function immediately sets the volume level t...

Page 21: ...ote control will switch the unit to the AV input selected at the volume level previously stored Setting the AV function Select the desired channel and volume using the input selector and volume knobs...

Page 22: ...ntrol is managed by a purpose specific integrated circuit this IC contains a programmable precision resistor network that can supply the desired attenuation level The same IC also contains an active s...

Page 23: ...r Authorised Dealer or Service Centre will be able to assist with this operation Cleaning the Unico Due Cleaning must be done after switching off the amplifier and allowing it to cool down Use a soft...

Page 24: ...battery 9 FUSES Inside the Unico Due there are six fuses On the CT board F3 F6 1AT 250V On the main board F3 F4 1 6AT 250V F1 F2 6 3AT 250V The value for the main fuses is 10AT 250V mains voltage 100V...

Page 25: ...ry pair Inputs 3 line RCA 1 USB 1 monitor Line outputs 1 tape RCA 1 DAC 1 subwoofer volume controlled Output connectors 4 4 bi wiring THD 0 25 1kHz 10W Power Consumption 360W at max power on 8 Dimensi...

Page 26: ...6 Special Functions 19 7 Notes about inputs 20 8 Safety and maintenance 21 9 Fuses 22 10 Technical specifications 23 Unison Research is a registered trade mark of A R I A Advanced Research In Audio S...

Page 27: ...pecjalnego centrum zajmuj cego si zbieraniem utylizacj wy ej wymienionych odpad w albo zwr ci do punktu sprzeda y gdzie dany produkt zosta zakupiony je li ma by on wymieniony na nowy odpowiadaj cy pro...

Page 28: ...ialavfall eller returnere produktet til forhandleren hvor produktet opprinnelig ble kj pt hvis det skal erstattes med et nytt tilsvarende produkt Spesielle oppsamlingsfasiliteter for produkter beregne...

Reviews: