background image

                         OPERATING MANUAL FOR 

KENTUCKY COLD

 

 

 

 

 

 4

 

SAFETY IN USE 

 
For personal safety when operating equipment is mainly responsible the operator. Manufacturer of the showcase is not 

responsible for personal injury or property damage and environmental damage caused while the unit is not used and 
serviced in accordance with the instructions for operation and maintenance and the applicable safety regulations. 

 

 4.1

In general 

!  Showcase may be used by the 

trained personnel only

. Never allow anyone, who is not authorized to use the display 

case and is not familiar with its functions, to manipulate it, carried its maintenance or other activities contrary to its 
intended use. Such improper operation may result in injury or damage the device. 

!  Showcase may be used only for their intended purpose and in accordance with the instructions. Any other use is in 

contrary with its purpose and it is considered as dangerous.  

!  For safety reasons, do not remove the cover or attempt to get into the case. There are no parts which you, as the 

user, can manipulate. Repair of any faults and maintenance, beyond that described in this manual, must be carried out 
by qualified service technicians. 

!  Do not block the ventilation holes of the equipment. 
!  Before use, check the exhibition space. Remove the remnants of food, unremoved cleaners, protective foil or other 

objects and clean the exhibition space thoroughly. 

!  Do not place the device on or near ignitable sources. 
!  Check the correct positioning and securing of shelves. Incorrect placement of shelves may lead to fall and cause injury. 
 

4.2

While using the showcase 

!  If the device is damaged in any way, turn it off immediately, unplug it from the power supply and contact your supplier. 
!  Operate the control panel buttons by using fingers exclusively. Using sharp, pointed or other objects to control the 

device will affect the warranty of equipment. 

!  Ensure that the load of shelves and exhibition space does not exceed the maximum permissible load (Chapter 5.4). 
!  When opening showcase do not press on the glass surface and do not use excessive force. Glass can break and cause 

injury. 

 

 

 4.3

After working with a showcase 

!  For cleaning, use only non-aggressive cleaning agents. 
!  For cleaning, do not use sharp objects. 
!  Never use water stream, there is a risk of electrical short circuits. Clean only with the damp cloth. 
!  During periods of disuse device, turn off the power supply. 
 

 4.4

Electrical safety 

!  If there is any damage to the electrical parts of the equipment, it is necessary to ensure the immediate repair. The 

damaged equipment must not be operated. 

!  Do not damage, alter or bend the power cord excessively. Do not tighten it and avoid its twisting. Placing heavy objects 

on the power cord and other compression may result in electric shock or fire. 

!  Use a single dedicated AC socket only. Do not use extension cords or multiple sockets, can cause overheating and 

electric shock or fire. 

!  The device is intended for indoor use only. It must not be exposed to rain, there is a risk of electric shock. 
!  If the installation of showcase in a moist environment is unavoidable, install a circuit breaker with effective protection 

against current leakage. If the circuit breaker is not installed, there is a risk of electric shock. 

 

 
 

 
 

Summary of Contents for KENTUCKY COLD GN1

Page 1: ...Refrigerated top table counter KENTUCKY COLD Operating manual...

Page 2: ...dance intended This manual is intended for all persons who come into contact with the device during the installation operation and maintenance Each of these persons must be thoroughly familiar with it...

Page 3: ...must be stored under the following conditions 1 Showcase should be kept in their original packaging in a dry and dark place 2 Do not turn upside down nor to side the showcase Do not place any objects...

Page 4: ...from such an activities the equipment manufacturer is not liable the risk is covered by the user solely Before first run please read the chapters 3 3 and 3 4 carefuly follow the steps noted there to...

Page 5: ...OPERATING MANUAL FOR KENTUCKY COLD 3 2 4 Dimensions KENTUCKY COLD GN1 KENTUCKY COLD GN2 KENTUCKY COLD GN3 KENTUCKY COLD GN4...

Page 6: ...OPERATING MANUAL FOR KENTUCKY COLD 4 KENTUCKY COLD 600 KENTUCKY COLD GN2 High KENTUCKY COLD GN3 High More of technical information can be found in Chapter 9...

Page 7: ...ssing or the guide is unclear contact your supplier 1 Showcase should be aligned to the horizontal position by using the adjustable feets on the bottom of the display case Align the showcase by turnin...

Page 8: ...shelves may lead to fall and cause injury 4 2 While using the showcase If the device is damaged in any way turn it off immediately unplug it from the power supply and contact your supplier Operate th...

Page 9: ...OPERATING MANUAL FOR KENTUCKY COLD 7 5 OPERATION 5 1 Control panel The control panel consists of 1 electronic control unit 2 light switch 3 main On Off...

Page 10: ...ress button The set value is displayed for about 15 seconds Increasing the temperature Press the button to get required value Press and realease the button to save it Decreasing the temperature Press...

Page 11: ...ial maintenance However it must be kept clean and remove the residues of exhibited goods and other contaminants Instructions for maintenance are obligatory to follow otherwise void the warranty Just r...

Page 12: ...showcase dries up completely to prevent mold and unwanted odors 6 2 Weekly maintenance Disconnect the showcase from power supply Empty showcase and let it reach room temperature Clean entire inner sp...

Page 13: ...r depending on the installation site It occurs when there is high humidity of the ambient air and water from the air coming into contact with cold surfaces This is normal In this case wipe with a dry...

Page 14: ...the procedure under Art 8 REGULATION OF THE EUROPEAN PARLIAMENT AND COUNCIL REGULATION EU No 517 2014 Components better be disposed of at the site which is specialized and thus will be possible to re...

Page 15: ...Temperature C 2 6 2 6 2 6 2 6 Voltage V Hz 230 50 230 50 230 50 230 50 Power W 290 330 480 650 Consumption kWh 24h 11 62 Weight kg 56 0 74 0 95 0 121 0 GN2 High GN3 High Atyp 600 Dimensions mm 750 x...

Page 16: ...Pos Name 1 Producer 4 Serial number 2 Contact 5 Technical data 3 Model 6 Production date UNIS COOL s r o Na Ba tici 201 739 01 Star M sto District Fr dek M stek Czech Republic Tel 420 558 655 211 Fax...