![Unique Classic UGP-24CR RH B Owner'S Manual Download Page 39](http://html1.mh-extra.com/html/unique/classic-ugp-24cr-rh-b/classic-ugp-24cr-rh-b_owners-manual_3921452039.webp)
15
OPERATING INSTRUCTIONS
Function Buttons:
OFF
F1
OFF
LOW SPEED
F2
MEDIUM SPEED
F3
HIGH SPEED
F4
LED LIGHT
F5
F1
F2
F3
F4
F5
OFF
Touch Controls
Fan Buttons:
Power on by pressing
any button of F2/F3/F4, fan starts
and F5 light automatically but does
not blink.
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
After Installation, motor and
lights are not working.
The power is not on
Make sure the circuit breaker and the
unit’s power is ON. Use a voltage meter
to check the power supply
The wire connection is not secure
Check and tighten wire connection
The touch panel and processor board
wiring are disconnected
Check wire continuity from control panel
to processor board
The touch panel and processor board
is defective
Replace the control panel or processor
board
Lights are working, but
motor(s) is not.
The motor(s) is defective
Replace the motor
The capacitor(s) is defective
Replace capacitor(s)
The control panel or processor board
is defective
Replace the control panel or processing
board
The range hood is vibrating
The blower system is not secure
Tighten the squirrel cage
The squirrel cage is not balanced
Replace the squirrel cage
Hood is not secured in place
Check the installation of hood, tighten
the mounting bracket
Summary of Contents for Classic UGP-24CR RH B
Page 7: ...7 PRÉ INSTALLATION Vue latérale Vue 3 4 Vu avant Vue de dessus MESURES ...
Page 18: ...18 SCHÉMA ET LISTE DES PIÈCES 20 19 17 16 15 18 1 2 3 4 6 7 8 9 10 12 13 14 ...
Page 31: ...7 PRE INSTALLATION Side View 3 4 View Front View Top View MEASUREMENTS ...
Page 42: ...18 PARTS DIAGRAM AND LIST 20 19 17 16 15 18 1 2 3 4 6 7 8 9 10 12 13 14 ...