12
Pump
down (refrigerant recovery)
9
S
Stta
arrtt c
co
oo
olliin
ng
g o
op
pe
erra
attiio
on
n..
((C
Ch
he
ec
ck
k iiff c
co
om
mp
prre
es
ss
so
orr o
off o
ou
uttd
do
oo
orr u
un
niitt iis
s
o
op
pe
erra
attiin
ng
g..))
P
Pu
um
mp
p-
-d
do
ow
wn
n ((rre
effrriig
ge
erra
an
ntt rre
ec
co
ovve
erryy)) iis
s tth
he
e p
prro
oc
ce
es
ss
s tto
o
c
co
olllle
ec
ctt rre
effrriig
ge
erra
an
ntt rre
em
ma
aiin
niin
ng
g iin
n iin
nd
do
oo
orr u
un
niitt a
an
nd
d
c
co
on
nn
ne
ec
cttiio
on
n p
piip
piin
ng
g lliin
ne
e a
an
nd
d s
stto
orre
e iitt iin
n o
ou
uttd
do
oo
orr u
un
niitt
ffo
orr tth
he
e p
pu
urrp
po
os
se
e o
off m
mo
ovviin
ng
g o
orr rre
ep
pa
aiirriin
ng
g a
aiirr
c
co
on
nd
diittiio
on
ne
err..
Loosen nut caps of gas and liquid service valves (
⑤
,
⑥
) and
service port cap of gas service valve (
⑦
).
Connect low pressure hose of manifold gauge (
③
) to service
port of gas service valve.
Low pressure hose valve of manifold gauge (
①
) must be
closed.
Completely close liquid service valve by rotating it in
clockwise direction with a hexagonal wrench.
When low pressure of manifold gauge drops to 0kgf/cm2,
completely close gas service valve by rotating it in clockwise
direction with a hexagonal wrench.
Immediately stop the operation of air conditioner. (Refrigerant
is not being circulated. Therefore breakdown of compressor
may occur if air conditioner is not stopped immediately.)
Disconnect manifold gauge and reassemble nut caps and
port caps (to prevent refrigerant leakage).
Low
High
Pressure
gage
1
2
3
5
4
7
6
8
IDU
ODU
Gas
Liquid
Summary of Contents for DPA-246LG
Page 2: ...FLOOR STANDING TYPE Air Conditioner Model DPA 246LR DPA 246LG ...
Page 16: ...14 2 DPA 246LR LGINDOORUNITOUTLINEANDSECTION ...
Page 19: ...17 1 INDOORUNIT 4 WIRING DIAGRAM ...
Page 20: ...18 2 OUTDOORUNIT ...
Page 22: ...20 1 DPA 246LR LGINDOORUNIT 5 EXPLODED DIAGRAM ...
Page 25: ...23 2 DPA 246LR LG OUTDOOR UNIT ...
Page 31: ...29 8 PCB DRIVING DESCRIPTION 1 DPA 246L R G INDOOR UNIT MAIN PCB CIRCUIT ...
Page 32: ...30 2 DPA 246L R G INDOOR UNIT FRONT PCB CIRCUIT ...
Page 33: ... 3 DPA 246L R G OUTDOOR UNIT PCB CIRCUIT ...
Page 43: ...SPLIT TYPE Air Conditioner Model DSA 0910LR M DSA 0910LG M ...
Page 46: ...3 2 OUTLINE AND DIMENSIONS 1 INDOOR UNIT DSA 0910LR G M ...
Page 56: ...13 4 WIRING DIAGRAM Indoor Unit DSA 0910LR G M ...
Page 59: ...16 6 CONTROL BLOCK DIAGRAM DSA 0910LR G M ...
Page 66: ...23 PCBDRIVINGDESCRIPTION ...
Page 67: ...24 1 PCB CIRCUIT DIAGRAM DSA0910LR G M ...
Page 76: ...33 3 EXPLODED DIAGRAM Indoor Unit DSA 0910LR G R ...