100% - bath calibration
Different bath tubs hold different amounts of water, thus calibrating the baths 100%
depth is essential to ensure bathomatic does not overflow. bathomatic can take
any depth to be 100% thus you have to teach it your choice of 100% depth or full
bath. Typically 100% is set to at least 20mm below the point of overflow. When the
bath tub is full let the water settle for a little while then select SET 100% in the
SERVICE MENU and press
to store the value. Before you attempt to SET
100% you must first SET 0%
It is strongly recommended that 100% bath calibration is made below the point of
overflow.
If 100% - bath calibration is set at the point of overflowing, due to the fluctuation of
depth reading bathomatic may never reach 100%, thus it may not stop filling should
100% fill is requested.
Right arrow increments the desired
depth D: in 10s to a maximum of 250%
FILL
Service
Menu
bathomatic will go into FILLING
bathomatic will go into PAUSED
Allow water to fill the bath to 100%
SET
100%
Main
Menu
Service
Menu
Service
Menu
3 x
— D: 000 — A:000 — r26
Top line in Service Menu
D: 000 - desired depth
A: 000 - current depth
r26 - firmware version