background image

  

12 

 

5. Camera Malfunction

 

 

WARNING: DO NOT ATTEMPT TO OPEN THE CAMERA HOUSING IN ANY CASE WITHOUT CONSENTING 
                   THE FACTORY.

 

 
Camera malfunction rarely happens.  In case camera malfunctions, the following troubleshooting procedures 
would help to minimize the problem; it definitely helps the user to find out the actual problem and may save a trip 
for sending the camera back to the factory. 
First of all, disconnect the 12-pin Hirose power connector and BNC cable from the camera unit. Make sure there 
is nothing connected to the camera at this time. 
Check the 12V DC power supply at the 12-pin connector cable and make sure it does provide the right voltage to 
the 12-pin connector. 
Make sure to set the camera shutter dial switch back to 0 position and NRM/ASM to NRM location.  
If frame grabber was connected to the camera, disconnect it. 
Now, power up the camera, and connect it to a TV monitor with a BNC cable.  Make sure the monitor and BNC 
cable are good.  Point the camera at a bright scene without a lens on, a blank or bright display should be seen on 
the TV monitor.  Covering the CCD camera with hand or lens cap should see a dark video.  If no video occurs, 
most likely the CCD camera is damaged.  Consult the technical support at the factory. 
If there is video but it is not clean or bad, it is possible that the CCD imager glass is dirty because of the dirt on 
CCD glass surface or the CCD camera is partially damaged.  Use high-pressure air to blow the dirt away if the 
CCD glass is not clean.  If the problem still exists, contact the UNIQ technical support for help. 
If there is video on TV monitor but not with a frame grabber, most likely the problem is from the frame grabber's 
software or hardware.  Consult the frame grabber factory for further details.  If a lens is used, make sure the iris is 
wide open. 
 

 
6. Technical Support Information

 

 

For technical assistance, contact UNIQ Technical Support or Applications Engineer at  

 
Phone:  

 

(408) 330-0818  

Fax:   

 

(408) 330-0886 

Email:  

 

[email protected]

 

 

Company contact information: 

 
UNIQ VISION, INC. 
2924 Scott Blvd. 

Santa Clara, CA 95054 
 
Phone:  

 

(408) 330-0818 

Fax:   

 

(408) 330-0886 

 

Our website:   

www.uniqvision.com

 

General Inquiries: 

[email protected]

 

Summary of Contents for UM-200

Page 1: ...0 UM 200 UM 201 Camera User s Manual 091 0210 V 1 1 08 09 17...

Page 2: ...unctions 5 3 1 12 Pin Connector 5 3 2 Shutter Speed Dial Switch 5 3 3 Normal and Asynchronous Capture Mode NRM ASM 5 3 4 Gain Control Mode 6 3 5 Gamma 1 0 and 0 45 Mode 6 3 6 Field and Frame Mode FLD...

Page 3: ...s Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or dam...

Page 4: ...201 is compatible with all standard NTSC RS 170 frame grabbers and TV monitors 1 2 Features Super HAD CCD Imager High resolution 768 x 494 EIA 752 x 582 CCIR Asynchronous capture High sensitivity wit...

Page 5: ...375 TV Lines H 560 TV Lines V 450 TV Lines S N Ratio 56dB AGC OFF Gamma 1 0 Min Illumination 0 05 lux Video Output 1 V p p 75ohm BNC or 12 pin Hirose AGC AGC MGC selectable Gamma Gamma 0 45 1 0 selec...

Page 6: ...a has the correct settings before powering up See section 3 for details Figure 1 Basic Camera Setup 2 2 Camera and Frame Grabber System Setups A basic camera and frame grabber system setup as shown in...

Page 7: ...on the rear panel Figure 4 For normal shutter speed it has 9 different shutter speeds to select from Position 0 is standard scanning speed 1 60 second As Position goes higher the shutter speed goes h...

Page 8: ...amma is the numerical value of the degree of contrast in a television picture Gamma correction is the system response modification by providing linear transfer characteristic from the input to output...

Page 9: ...rame resolution Frame Mode In frame mode every other horizontal line is scanned out this is different from field mode as described above For odd field line 1 is scanned out first For even field line 2...

Page 10: ...on the rear panel of the camera For example if the shutter speed on rear panel reads 1 1 125 then the exposure should be equal to 1 125 sec Once XFER occurs the new reset shutter video will appear Th...

Page 11: ...and Gen lock The UM 200 UM 201 camera automatically locks to the external sync source The external sync source must match the camera HD and VD specification which are 15 734KHz and 59 94Hz respective...

Page 12: ...4 7 Strobe Set NRM ASM switch to ASM mode and make sure the FRM FLD switch on rear panel is set to FRM mode in order to achieve full frame resolution The strobe application is similar to high speed s...

Page 13: ...without a lens on a blank or bright display should be seen on the TV monitor Covering the CCD camera with hand or lens cap should see a dark video If no video occurs most likely the CCD camera is dam...

Reviews: