3.4 Momentary Switch (UP/Down Switch) 

 

Position 

No. 

Functional Select (NS) 

Up/Down Switch 

Normal 

N/A 

Gain Adjustment 

Move up or down to adjust gain 

Reference Adjustment 

Move up or down to adjust reference 

Factory Page 

Move up or down to recall factory page 

User Page 1 

Up: Recall; Down: Save 

User Page 2 

Up: Recall; Down: Save 

User Page 3 

Up: Recall; Down: Save 

User Page 4 

Up: Recall; Down: Save 

 8 

Normal/2x2 binning 

Up: Normal speed; Down: 2x2 binning 

Reserved 

 

Reserved 

 

Reserved 

 

Reserved 

 

Reserved  

 

Reserved 

 

Reserved 

 

 

Camera settings can be saved into four different user pages.  Once the user page is saved and set 
between shutter speeds 4 and 7, it will be activated as long as the camera is powered ON.  User 
Page works in both rear plate control and RS232C communication selections.   

 

 

 
 

 

 
3.5 Gain Control (AGC/MGC)
 

Note:  This gain potentiometer only applies to cameras without Up/Down switch 

on rear plate. 

 
Manual gain control (MGC) 
 

MGC is standard factory setting on this camera. The manual gain control can be adjusted from 4 dB 
to 36 dB. Adjusting the gain potentiometer located on rear panel will change the gain value. 

 
 
Automatic gain control (AGC): 
 
AGC is not available and it is not recommended to use.  Contact UNIQ for further details. 
 
                     

                                                               

 

 

                          

 

   Figure 6. Gain potentiometer

Figure 5. Up/Down Switch 

Summary of Contents for Camera Link UP-1800DS-CL

Page 1: ...UP 1800DS CL Camera Link Camera User s Manual 091 1805 V 1 2 08 09 17 ...

Page 2: ...2 Precautions 2 Limited Warranty 2 1 Introduction 3 2 Camera Setup 5 3 Camera Functions 5 4 RS 232C Communication Control 9 5 Digital Interface Timing 10 6 Camera Functional Timing 11 7 Camera Accessories 13 8 Technical Support 13 ...

Page 3: ...ts Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or damages due to defects in material or workmanship which occur during normal use It does not cover damages or failures which result from shipment mishandling abuse misuse or modification A Return Materia...

Page 4: ...Progressive Scan CCD Imager 1380 x 1034 active pixels 30 Hz frame rate 2 x 2 692 x 516 Binning at 55 FPS 10 bit Camera Link output Analog output Full frame shutter 58 dB Asynchronous reset at full frame shutter 50 MHz pixel clock RS 232C interface Control C mount lens 1 3 Applications UP 1800DS CL applications include machine vision automated inspection motion capture and analysis high resolution ...

Page 5: ...ing Sync HD 31 367 KHz VD 30 0 Hz Digital Video Output Camera Link format Analog Video Output 1 V p p 75ohm BNC or 12 pin Hirose S N Ratio 58 dB Min Illumination 0 02 lux Gain MGC Gamma 1 0 Electronic Shutter 1 30 1 62 000 selectable Lens Mount C Mount Operating Temperature 10 C 55 C Power Requirement 12 V DC 470 mA 5 6 W 12 V DC 460 mA 5 5 W Dimension 50mm x 39mm x 83mm Ext Sync Internal External...

Page 6: ...1 12 Pin Connector The 12 pin Hirose connector is located on the rear panel of the camera All ground signals on pin 1 3 5 and 8 are common grounds 12 V DC input is recommended on pin 2 but this camera should withstand 12 V 1V input voltage Make sure to set the NM AM switch to NM position for external HD and VD locking Figure 2 below shows a top view of the 12 pin Hirose connector Pin No UP 1800DS ...

Page 7: ... DS this time for 2x2 binning shutter speed selection For asynchronous capture applications set NM AM mode to AM location Position No Functional Select NS Shutter Speed Select DS Shutter Speed sec NM Mode Shutter Speed sec DS Mode Asynchronous Capture for normal and binning sec AM 0 Normal 1 30 Off 1 50 No shutter 1 Gain Adjustment 1 60 1 100 1 120 2 Reference Adjustment 1 120 1 133 1 240 3 Factor...

Page 8: ...gs can be saved into four different user pages Once the user page is saved and set between shutter speeds 4 and 7 it will be activated as long as the camera is powered ON User Page works in both rear plate control and RS232C communication selections 3 5 Gain Control AGC MGC Note This gain potentiometer only applies to cameras without Up Down switch on rear plate Manual gain control MGC MGC is stan...

Page 9: ...A3 Video LEN and FEN data output 7 20 SerTC SerTC Rx Rx Differential pair serial communications from frame grabber 8 21 SerTFG SerTFG Tx Tx Differential pair serial communications to frame grabber 9 22 CC1 CC1 HD HD Camera Control 1 CC1 Horizontal signal input 10 23 CC2 CC2 VINT VD VINT VD Camera Control 2 CC2 Vertical signal or asynchronous reset input 11 24 CC3 CC3 Reserved Reserved for custom o...

Page 10: ...f If no number entered gain will be increased by factor of 1 If a number is entered then number will be added to stored gain gd Gain decrease Hexadecimals 000 3ff Same as gi above except it will be decreased gn Gain number Hexadecimals 000 3ff Refer to the gain curve below for details bi Reference increase Hexadecimals 000 3ff If no number entered reference will be increased by factor of 1 If a nu...

Page 11: ...ing 5 1 Pixel Clock 5 2 Line Enable 5 3 Frame Enable 5 4 Line Enable for 2x2 binning mode 5 5 Frame Enable for 2x2 binning mode Note Normal Mode 2x2 Binning Mode HD 31 367 KHz 28 835 KHz VD 29 988 Hz 55 02 Hz PCLK 50 MHz 25 MHz ...

Page 12: ...er speed position 0 30 fps 6 2 Free Run shutter speed position from 1 to F 6 3 Asynchronous Capture shutter speed position 0 6 4 Asynchronous Capture shutter speed position from 1 to E 6 5 Asynchronous Capture with Pulse Width Control shutter speed F ...

Page 13: ...l Synchronization and Gen lock Timing 6 7 Long Term Integration via 12 pin Hirose connector ONLY The UP 1800DS CL camera can be integrated up to 2 seconds To start integration pin 11 of the 12 pin connector must be connected to GND or 0V The integrated video will be shifted out following the next vertical drive after pin 11 goes back to high or 5V level as shown in figure 9 below If a frame grabbe...

Page 14: ...or UP 1800DS CL camera There are a variety of C mount lenses in the market that works with UP 1800DS CL camera Make sure the quality and specification of the lens match the camera s application Some of the most popular lenses in the market such as Cosmicar Fujinon Rodenstock and Schneider are recommended 7 3 Camera Link Cable Camera Link cable can be purchased from 3M Mouser Digi Key and frame gra...

Reviews: