6.SETTING AND ADJUSTMENT OF READING
46
6. SETTING AND ADJUSTMENT OF READING
6-1. Operation
6-1-1. Weighing section
This function specifies the weighing section length in millimeter. The weighing section
represents the effective length of the portion of the belt that carries measured materials
whose weight is detected by the weighing sensor.
Operation
6-1-2. Rated feed rate (FS)
This parameter specifies the full-scale value to the feed rate. The value should be set so
that FEED RATIO indicates 100% when LOAD RATIO is 100%.
Operation
6-1-3. Feed unit
This parameter specifies the unit for FEED RATE and TOTAL measurement.
Operation
Materials to be measured
Weighing section
Load detector (load cell)
Belt
MODE
OPERATION
WEIGHING SECTION
→
→
Range: 0.0001 – 99999mm (5 digits, decimal place arbitrary)
Range: 0.0001 – 99999 (5 digits, decimal place arbitrary)
MODE
OPERATION
RATED FEED RATE
→
→
Options: kg/h,kg t/h,t
MODE
OPERATION
FFED UNIT
→
→