8.INTERFACE
126
8-4-2. D/A output channel
This menu item selects a channel for which the following parameters are specified: [D/
A OUTPUT MODE], [D/A ZERO OUTPUT WEIGHT], [D/A FULL SCALE
VALUE], [D/A OUTPUT CONPENSATION], [D/A LOWER LIMIT], and [D/A
UPPER LIMIT].
* You can specify separate settings for the two channels (ch1, ch2). Do not fail to select
the correct channel for parameter settings.
Operation
8-4-3. D/A output mode
This menu item selects, for each channel, the type of data to be output from the D/A
converter.
Operation
8-4-4. D/A zero output weight
This menu item specifies, for each channel, physical values corresponding to 4mA
current output. The units for these values are determined automatically with the
selection in 9-3-3. If “CONTROL RATE” is selected in [D/A OUTPUT MODE],
allowable input range is from 0.0 to 100%.
Operation
MODE
OPTION
→
→
Options: ch1, ch2
→
PAGE
D/A OUTPUT CHANNEL
Options: 4mA FIXED OUT, 20mA FIXED OUT, BELT SPEED,
WEIGHT DENSITY, FEED RATE, LOAD RATIO,
FEED RATIO, CONTROL RATE
MODE
OPTION
→
→
→
PAGE
D/A OUTPUT MODE
Input range: 0-99998 (5 digits, decimal place automatically determined)
0.0– 100.0% (4 digits, decimal place fixed)
MODE
OPTION
→
→
→
PAGE
D/A ZERO OUTPUT WEIGHT