10.SEQUENCE SETTING
37
■
Weight confirmation at start time
The setting is valid in the sequence mode.
Alternatives:
[
OFF
]
[
ON
]
■
AZ
times
The setting is valid in the sequence mode.
Setting range:
00 to 99 times
■
Judging times
The setting is valid in the sequence mode.
Setting range:
00 to 99 times
When the start signal is input, if
(1) the net
≧
final weight – SP1, or
(2) the final weight – CPS
≦
0,
the feeding gate signal (SP1, SP2, or SP3) is not turned ON, but a sequence error
results. (Sequence error 5)
((1) is applicable only when the “weight confirmation at start time” setting is ON.)
When the start signal is input, tare subtraction is performed at intervals of these
times.
When the completion signal is turned ON, Over weight/Under weight comparisons
are made at intervals of these times.