3.CONNECTION
14
3-6. Voltage Output Connection
The voltage output terminal is an interface to extract analog voltage proportional to
sensor signal inputs.
・
Since the VOL OUT terminal is not insulated from the internal circuit, use a shielded
cable for connection with the external equipment and wire within 2 - 3m.
・
Do not short-circuit. Doing so will cause a failure.
・
Do not apply voltage from the outside. Doing so will cause breakage.
+
-
F.G or
External
2
1
SIG
COM
VOL OUT
GND
←
F371 inside
outside
→
equipment