7.HOLD FUNCTIONS
58
The Hold Function in General
●
The delay times of the judging signal and the H/E signal do not include a
delay time of the analog circuit (low-pass filter). Also, the delay times are
calculated without the digital filter. Since the judging signal and the H/E
signal are generated for the value produced through the analog and digital
filters, transmission of the signals becomes slower and the delay of each
output signal increases with enhancement of the filters.
●
If the H/M signal is continuously input, the previously held value is reset by
the on timing, and hold operation newly starts.