background image

14

SEQUENCE MODE

In Sequence mode you measure and save the 
pressure on all tires in a predefined order (2 
or 4 tires depending on which sport you have 
chosen in setup).

You need to define the order of the tires in 
Setup mode (see ”SEQUENCE SETUP” on page 
19) before you can use this mode.

Your choice in setup of digital gauge mode 
or analog gauge mode will also be used in 
Sequence mode. 

You can save up to 20 sequences in the 
memory

 so you have easy access to the actual 

tire pressure values from a full day of racing 
without having to write anything down. Each 
sessions is time stamped and can be trans-
ferred to the Unipro app via BLE.

Keep pressing the 

left

 button (

3

) at startup to 

go directly to Sequence mode.

Digital gauge mode

Digital view with large current value for 
Front Left tire, an arrow to show the se-
quence direction and numbers in the corner 
showing that you are measuring tire 2 of 4.

Press the 

right

 button ( ) to save the value 

and move on to the next tire. 

If you make a mistake and want to clear the 
measurements in the current sequence, press 
and hold the 

left

 button (

3

) down until the 

text shows the first tire again and the progress 

is showing either 1/4 or 1/2.

Analog gauge mode

Analog view with current value for Front 
Right tire (FR above the needle) shown as 
numbers (below the needle) and as value 
on the analog scale.

Also when using the analog gauge mode, you 
press the 

right

 button ( ) to save the value 

and move on to the next tire. 

Of course it is up to you to decide if you want 
to save the pressure value before or after you 
make adjustments to the pressure.

Advantages of the digital gauge mode

As you can see in the description on this page, 
the digital gauge mode shows more details 
than the analog gauge mode:

•  Current tire shown with full name.
•  Pressure value in very large text.
•  Numbers to show where you are in the 

sequence.

•  Arrow to show the direction to move in 

the sequence.

If you use the Sequence mode, we recommend 
that you also use the digital gauge mode to 
take advantage of the extra features.

Operating UniTire

R e f e r e n c e 

G u i d e

Summary of Contents for UniTire V2

Page 1: ...UniTire V2 Pressure Gauge User Guide...

Page 2: ...e in water Be careful not to drop it on the ground Do not leave it under heavy objects Be careful not to cut the cable with sharp objects Clean only with a dry cloth Refer all servicing to approved se...

Page 3: ...ES 10 CLEAR THE STORED PRESSURE VALUES 10 TRANSFERRING DATA 10 SETUP MODE 10 TURN UNITIRE OFF 10 BUILT IN HELP 10 Reference Guide 11 BASIC INFORMATION 11 3 WAYS TO PRESS BUTTONS 12 TURN UNITIRE ON 12...

Page 4: ...make changes and improvements to any of the products described in this document without prior notice Part numbers 17 02 001 UniTire V2 black 17 02 002 UniTire V2 dark blue 17 02 003 UniTire V2 red 17...

Page 5: ...alves which makes it easy to use with right or left hand and allows you to let out more or less air The handle is angled in a way which al lows easy access to any type of tire valve The standard press...

Page 6: ...OLUTION DISPLAY The large round high resolution display gives a quick overview HIGH PRECISION 0 0002 bar resolution and 0 01 bar typical accuracy HANDLE CABLE Flexible cable with power and communicati...

Page 7: ...0 hours Pressure units bar mbar psi HPa Torr Languages DEN FRA GBR GER ITA NED Memory 20 tires sets Dimensions 72 5 x 104 3 x 19 0 mm 2 85 x 4 11 x 0 75 Weight 290 g 10 23 ounces Controls Two buttons...

Page 8: ...8 I n t r o d u c t i o n Examples...

Page 9: ...utton s After that you will be on either the pressure screen 1 the pressure sequence screen 2 or in the setup mode 3 MEASURE AND ADJUST THE PRESSURE IN PRESSURE MODE If you start in Pressure mode the...

Page 10: ...d down the left button 3 from Recall mode TRANSFERRING DATA From Recall mode press the left button to go to Transfer mode While the transfer screen is active the Bluetooth communication is turned on a...

Page 11: ...power cable The cable which connects the pressure handle with the pressure gauge carries the power and communication between the gauge and the handle The cable is very flexible and durable but be car...

Page 12: ...y showing the startup screen as long as you keep pressing the button s Then you will see the pressure screen 1 the pressure sequence screen 2 or the setup screen 3 Startup screen with software version...

Page 13: ...new pressure value is put in the history list the oldest one drops off the list The newest value is at the top This order is also indicated by the arrow in the right side of the display The history l...

Page 14: ...value and move on to the next tire If you make a mistake and want to clear the measurements in the current sequence press and hold the left button 3 down until the text shows the first tire again and...

Page 15: ...e measured values in Stealth mode the actual values are stored in the memory so you will be able to see them in Recall mode Stealth mode works both with digital and analog gauge mode Read more about s...

Page 16: ...he left button 3 down until the circle shows the first tire again When you save the measured values in Stealth mode the actual values are stored in the memory so you will be able to see them in Recall...

Page 17: ...ge 1 out of a total of 2 pages The maximum number of pages is 5 The pressure values use the unit selected in Setup mode The unit is shown in square brackets at the bottom of the screen Navigating the...

Page 18: ...g Synchronize the time and date Set the owner s name Update the firmware Transfer the pressure and temperature Change all settings When transfer is in progress you will be able to see the progress bar...

Page 19: ...can be used for all sports where tire pressure measurements are needed Choose your sport or a sport with the same number of wheels as your sport The SET SPORT screen will list the pre defined sports S...

Page 20: ...button STEALTH MODE SETUP This is where you choose if you want to use the Stealth mode when measuring and storing tire pressure in Sequence mode Set Stealth mode to On if you want to hide pressure va...

Page 21: ...ge is always the same three letters for example DEU is always the abbreviation for Deutsch German whether the device is set to German or English To set the language to English press the right button a...

Page 22: ...amount of time Scroll through the choices by pressing the left button Select and move on to the next setup screen by pressing the right button OPERATION SETUP Choose between right hand and left hand o...

Page 23: ...ty Take the batteries out and put them in again Change the batteries with new ones Some of the scale is missing in analog mode It is supposed to be this way in Stealth mode with analog gauge view Chan...

Page 24: ...nsert batteries with the right polarity If you should by accident put them in the opposite direction you will not hurt UniTire or the batteries When assembling UniTire again slide the rear part into t...

Page 25: ...ial and workmanship for two years from the date of purchase The guarantee is void if the product has been subject to misuse accident or negligence or has been tampered with or modified in any way with...

Page 26: ...18 Connectable 17 Connected 18 Contrast setup 21 Contrast too low 23 Controls 7 Copyright IV D Digital gauge advantages 14 Digital pressure mode 13 Digital stealth mode 14 15 16 Dimensions 7 Display...

Page 27: ...ontrast 21 Setup gauge mode 19 Setup language 21 Setup max range 20 Setup mode 10 13 Setup sequence 19 Setup sport 19 Setup stealth mode 20 Setup stealth target 20 Spare part number IV Specifications...

Page 28: ...Unipro ApS Viborg Hovedvej 24 DK 7100 Vejle Denmark Tel 45 7585 1182 www uniprolaptimer com...

Reviews: