USAGE INSTRUCTIONS

Press the handle (A) till the very end, and then insert the 

spoke between the two pins on the tool (B). Make sure, 

the spoke is completely parallel with the tool, which is 

achieved by positioning the spoke to the side spacers (C) 

on the two pins.
Do not release the handle, but gently release the pressure 

and follow the path of the handle till it stops slowly, 

like shown on the picture 2. If not certain, repeat the 

measurement several times until you receive repeatable 

results. 
If you are uncertain of the spoke diameter, use the gauge 

on the top of the tool (D). 
Having the spoke diameter and the measured value, 

check conversion table to determine the current tension.

We suggest to measure the spoke tension at normal room 

temperature.

ENG

CALIBRATION INSTRUCTIONS

Insert the calibration spoke (E) into the Spoke Tension 

Meter and use the same procedure as with a normal 

spoke, like shown in the picture 4. After releasing the 

handle, the indicator must show equal value to the one 

specified on the calibration spoke.
If the value is not correct, screw the calibration bolt (F) on 

the back side of the tool. If the indicator shows less that 

it should, unscrew the calibration bolt counter clockwise 

direction for a few turns. If the indicator is showing more, 

screw the calibration bolt clockwise direction. Repeat the 
process until you reach the desired value.
Calibration spoke must be stored in the box and only used 

for calibration of this tool.
For additional help, contact Unior’s technical assistance at 

[email protected].

1

4

2

3

Summary of Contents for 1752/2

Page 1: ...re in izmerjeno vrednost poglej v priloženo tabelo konverzij in odčitaj trenutno napetost Priporočamo merjenje napere pri sobni temperaturi SLO NAVODILA ZA KALIBRACIJO Vstavite kalibracijsko napero E v orodje za merjenje napetosti naper in po istem postopku kot z normalno napero izmerite vrednost kot je to prikazano na sliki 4 Odčitana vrednost mora biti enaka vrednosti napisani na kalibracijski n...

Page 2: ...rrent tension We suggest to measure the spoke tension at normal room temperature ENG CALIBRATION INSTRUCTIONS Insert the calibration spoke E into the Spoke Tension Meter and use the same procedure as with a normal spoke like shown in the picture 4 After releasing the handle the indicator must show equal value to the one specified on the calibration spoke If the value is not correct screw the calib...

Page 3: ... 90 60 70 29 100 100 100 70 80 50 30 110 110 110 80 85 55 31 125 120 120 90 90 60 32 145 130 130 100 100 65 50 33 165 140 145 110 110 70 60 34 185 155 160 120 120 80 65 35 200 175 175 130 135 90 70 50 36 195 190 140 155 100 75 60 37 200 155 170 115 85 70 38 175 180 135 100 80 39 195 190 155 110 95 40 200 180 120 115 41 200 135 130 50 42 155 145 55 43 175 165 60 44 195 185 70 45 200 85 46 105 47 12...

Page 4: ... 65 50 50 24 155 130 90 90 70 60 60 25 175 155 100 100 80 70 70 26 195 170 110 110 90 80 80 27 185 120 125 100 85 90 28 200 130 145 115 90 100 29 140 165 135 100 110 30 150 185 155 110 120 31 160 200 175 125 135 32 175 195 145 155 33 195 170 175 34 195 195 35 MEASURED VALUE FROM TENSION METER Unitsareinkilogramsforce 1Kfg 10Newtons N Unior d d Kovaška cesta 10 3214 Zreče Slovenia T 386 3 757 81 00...

Reviews: