Transport, installation and acceptance
34
6.3 Installing and connecting
NOTICE
If there is an “X” after the certificate number, pay attention to the conditions on
installation and operation in the type examination.
The local installation provisions, especially the requirements of IEC/EN 60079-
14, are to be observed.
DANGER
Risk of explosion!
Non-approved cable entry points pose a hazard!
If non-approved cable entry points are used, explosion protection is no longer
guaranteed!
Use only cable entry points approved for the required ignition protection type!
When selecting/replacing cable and line entry points, comply with the technical
data!
Open holes and unused cable entry points pose a hazard!
Explosion protection is no longer guaranteed if there are open holes or unused
cable entry points!
Always close up open holes and unused cable entry points with sealing plugs or
stoppers approved for this purpose!
Sealing plugs must be inserted with a tool!
When selecting/replacing suitable sealing plugs, comply with the technical data!