UBio-X Pro Lite User Guide
62
UNIONCOMMUNITY Co., Ltd.
Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu,
Seoul, Korea (zip code : 05836)
Tel : +82-2-6488-3000, Fax : +82-2-6488-3099
E-Mail :[email protected]; http://www.unioncomm.co.kr
None
General case. It does not use Wiegand out port.
26bit
Because it sends “
Site code [1byte] + User ID [
2 byte]”, set the user ID
less or equal than 4 digits.
Send example) In case of SiteCode:045(2Dh), UID:6543(198Fh)
1 00101101 0001 1001 10001111 0
34bit
Because it sends “
Site code [1 byte] + User ID [
3 byte]”, set
the user ID
less or equal than 7 digits.
But, if the user ID is 8 digits, ignore site code
and send only the “User
ID [
4byte]”.
Send example) SiteCode:001(1h), UID:123456(1E240h)
0 00000001 00000001 11100010 01000000 0
Custom
It is set by the user definition, which only can be set in the server, and
the setting type only can be inquired in the terminal.
Click
[OK]
button to apply the set value, and click
[Back]