Installing the CiTO Power UPS is as easy as following the steps shown. Be 
aware that the Power Switch must be kept in the “ON” position and all 
equipment must be plugged into the Battery Power Supplied Receptacles, 
otherwise, the UPS will be disabled and your equipment will not be protected 
during a power failure. 

 

1. Inspection

 

Remove the UPS from its packaging and inspect it for damage that may 
have occurred during shipping.    If any damage is discovered, repack the 
unit and return it to the place of purchase.   

 

 

2. Placement 

Install the UPS unit in any protected environment that provides adequate 
airflow around the unit, and is free from excessive dust, corrosive fumes 
and conductive contaminants.  DO NOT operate your UPS in an 
environment where the ambient temperature or humidity is high. 

 

 

3. Charging 

This unit is shipped from the factory with its internal battery fully charged. 
However, some charge may be lost during shipping and the battery should 
be recharged prior to use.    Plug the unit into an appropriate power supply, 
then switch on UPS and allow the UPS to charge fully by leaving it plugged 
in for at least 8-10 hours with no load (no electrical devices such as 
computers, monitors, etc.) connected. 

 

Summary of Contents for EASY CPF-M400S

Page 1: ...USER S MANUAL CiTO Power EASY Series CiTO Power Off Line CPF M400S CPF M600S CPF M400U CPF M600U Uninterruptible Power Supply ...

Page 2: ... UPS and the connected equipment should not exceed 3 5mA z Do not dispose of batteries in a fire as they may explode z Do not open or mutilate the battery or batteries Released electrolytes are harmful to the skin and eyes It may be toxic z A battery can present a risk of electric shock and of having a high short circuit current The following precaution should be observed when working on batteries...

Page 3: ...rcuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Test before touching System Description Top 1 Power On Off Switch 2 Green LED AC Mode 3 Yellow LED Battery Mode 4 Red LED Fault LED 5 All receptacles are surge protected 6 3 receptacles are battery power supplied Side 7 AC Input 8 Breaker 9 RS 232 Interface 10 Modem Phone Line Surge Protection 11 U...

Page 4: ...he place of purchase 2 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants DO NOT operate your UPS in an environment where the ambient temperature or humidity is high 3 Charging This unit is shipped from the factory with its internal battery fully charged However some ...

Page 5: ...outlets These receptacles do not provide any power during a power failure Note DO NOT plug a laser printer copier space heater vacuum or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 6 Modem Phoneline Connection Plug incoming internet line into the In socket at the side panel of the UPS Use one more internet line cable and ...

Page 6: ...TO Power UPS Press power switch again to turn off the UPS 9 DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS 10 Battery Replacement CAUTION Battery replacement should be performed by qualified service personnel Follow the charts below to replace the batteries St...

Page 7: ...ver gently extract batteries from the case Chart 2 Step 3 Disconnect the two wires connecting it to CiTO Power UPS and replace the same type of batteries Dispose of the old batteries properly at an appropriate recycling facility Chart 3 ...

Page 8: ...PS on the same LAN no matter how far from the UPSs Installation procedure 1 Go to the website http www ups software download com winpower htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software When your compute...

Page 9: ...minutes DISPLAY LED Power on Backup Fault Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding every 0 5 second AUIBLE ALARM Fault Continuous Sounding PROTECTION Full Protection Overload Overcharge Short Circuit and Modem Phone Line Surge Protection Dimension DxWxH 300X125X85 mm Net Weight 3 2kgs 3 5kgs Schuko All for surge protection 3 plus battery backup PHYS...

Page 10: ...Trouble Shooting If the UPS failed to operate properly please review the following points firstly ...

Reviews: