8. TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

NOT RUNNING

NO REFRIGERATION

WATER LEAKS OUT

• The power plug is loose or 
   disconnected. 
• The breaker switch has turned off.

• The condenser surface is dirty 
   and blocked.
• The heat exhaust fan not working.
• The external environment 
   temperature is too high.
• The compressor is not working.
• The refrigeration system pipeline 
   is blocked.
• Possible power overload.

• The drain pipe is blocked.
• The filter is dirty.
• The water tank is full of water.

• Clean out the drain pipe.
• Clean the filter.
• Remove drain cap and empty the 
   water.

• Clean the condensor surface and 
   vents.
• Check fan.
• Move to more a suitable place
   to use.
• Check the capacitor to the 
   compressor.
• Check pipeline system and clean.
• Check for proper voltage.

• Insert the plug into the wall outlet.
• Check breaker on main panel and reset.
• Ask the technical service department 
   for assistance.

• The warranty period of this machine is one year. Our company has a technical department to 
   provide sevice to our customers.

• If the customer disassembles or modifies the unit in any way, the unit is not covered by the warranty.
 
• If the unit is out of warranty, the customer is responsible for service and additional costs if needed.

Summary of Contents for KOOLZONE SAC-3000AS

Page 1: ...USER MANUAL SAC 3000AS KOOLZONE MOBILE SPOT COOLER FOR MORE INFO...

Page 2: ...THANK YOU FOR PURCHASING THE KOOLZONE MOBILE SPOT COOLER PLEASE READ THE INSTRUCTIONS BEFORE USING KEEP THESE INSTRUCTIONS FOR REFERENCE KOOLZONE 2...

Page 3: ...Y PRECAUTIONS PAGE 4 5 2 SPECIFICATIONS PAGE 6 3 ACCESSORIES PAGE 6 4 PARTS OF THE MACHINE PAGE 7 5 INSTALLATION PAGE 7 6 OPERATING INSTRUCTION PAGE 9 7 MAINTENANCE AND INSPECTION PAGE 13 8 TROUBLESHO...

Page 4: ...r gasoline kerosene LPG aluminum magnesium and plumbum They could cause possible fire or explosion Only a professional repair service should disassemble the unit in order to avoid warranty voidance or...

Page 5: ...ge from 64 F to 104 F otherwise it may cause the unit to slow the air flow or shutdown To prevent an accident or damage the unit can not be used in the following locations Not grounded Unlevel ground...

Page 6: ...Heat Exhaust Duct Socket Screws Heat Exhaust Duct REFRIGERANT RATED CHARGE SIZE WEIGHT OPERATING TEMPERATURE LIMIT Single phase 115 V 60 Hz High 10 8 A 1210 W Low 10 4 A 1170 W 10 236 BTU Fully Close...

Page 7: ...DUCT Make sure the notch part molded arrow on duct lines up with the slotted black line in the cold air exit Install and turn to center the curved duct with the front of the unit INSTALLING THE COOLIN...

Page 8: ...perature range it may not work properly If the unit is moved and or tilted please wait at least 3 hours for the refrigerant to stabilize before turning on the unit After pressing the power button to s...

Page 9: ...OR OVERLOAD OVERHEAT PROTECTION If the compressor overheats or overloads due to high or low voltage or high ambient temperature the built in safety protection for the compressor will start working and...

Page 10: ...laced on level ground Unlevel ground stairs emergency exits should not be used Minimum distance needed is 12 from any wall While the unit operates please do not place obstructions in front of the filt...

Page 11: ...Tank Using Hose Connection Included Hose Hole Manual Extraction CASTER WHEEL LOCK UNLOCK The front wheels come with locks For safety lock the casters and check the unit for movement Please check the a...

Page 12: ...with heavy use consider vacumming filter before rinsing Rinse with water and dry thoroughly before reuse When cleaning the surface of the unit do not use abrasive materials or chemicals which could d...

Page 13: ...n pipe Clean the filter Remove drain cap and empty the water Clean the condensor surface and vents Check fan Move to more a suitable place to use Check the capacitor to the compressor Check pipeline s...

Page 14: ...OTHER DEVICES SHARING AN OUTLET MAY CAUSE A POWER OUTAGE 2 IF USING AN EXTENSION CORD A 12 AWG IS RECOMMENDED 3 DO NOT BLOCK THE HEAT EXHAUST DUCT BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT TO OV...

Page 15: ...PLEASE NOTE OPTIMUM OPERATING TEMPERATURE RANGE FOR KOOLZONE MOBILE SPOT A C COOLER IS FROM 77 113 FAHRENHEIT WHEN USING THIS UNIT ON COOLING MODE THE AMBIENT TEMPERATURE WILL BE REDUCED BETWEEN 10 15...

Page 16: ...X EXCLUSIVELY DISTRIBUTED BY UNINEX INTERNATIONAL 5780 SMITHWAY STREET COMMERCE CA 90040 T 800 864 3288 323 890 9246 F 323 890 9249 MANUFACTURE NAKATOMI CO LTD 6445 2 TAKAI TAKAYAMA KAMITAKAI NAGANO J...

Reviews: