When worn on the body, always place the radio in a UNIMO recommended clip or carrying case meant for

this product. The use of other than recommended or approved body-worn accessories may result in RF

exposure levels which exceed the FCC's occupational /controlled environment RF exposure limits.

CAUTION

To ensure that your exposure to RF EME is within the FCC limits for occupational use, you must observe

and adhere to the above points.

Electromagnetic Interference Compatibility

Electronic devices are susceptible to electromagnetic interference(EMI)if they are not adequately

shielded or designed for electromagnetic compatibility. Because this transceiver generates RF energy, it

can cause interference to such equipment.

>Turn OFF your transceiver where signs are posted to do so. Hospitals and health care facilities use

equipment that is sensitive to electromagnetic radiation.

> Turn OFF your transceiver while on board an aircraft when so instructed, Use of the transceiver must

be in accordance with airline regulations and/or crew instructions.

1. PRODUCT INTRODUCTION

THE PJ-400NW LMR(Land Mobile Radio) of UNIMO Technology Co. Ltd. is a sophisticated

State-of-The-Art unit which incorporates The modern technology available in Tow-Way

Radio Communications.

The use of microprocessor technology makes changing radio characteristics such as

operating frequencies and squelch codes both fast and economical any computer equipped

PJ-400NW dealer can easily reprogram your radio's operating characteristics, or your radio

can be "Cloned" from a radio already programmed to your desired frequencies and codes.

PJ-400NW LMR satisfies tough environmental requirements while providing cost effective

and reliable communications.

Summary of Contents for PJ-400NW

Page 1: ...e limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio Frequency energy and if not installed and used in accordance with th einstruction may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If th...

Page 2: ...re exposed to RF energy as a consequence of their employment and such persons have been made aware of the potential for exposure and can exercise control over their exposure This means you can use the transceiver only if you are aware of the hazards of operating a transceiver and are familiar in ways to minimize these hazards This transceiver is not intended for use by the general public in uncont...

Page 3: ...igns are posted to do so Hospitals and health care facilities use equipment that is sensitive to electromagnetic radiation Turn OFF your transceiver while on board an aircraft when so instructed Use of the transceiver must be in accordance with airline regulations and or crew instructions 1 PRODUCT INTRODUCTION THE PJ 400NW LMR Land Mobile Radio of UNIMO Technology Co Ltd is a sophisticated State ...

Page 4: ... 4 Fig 1 PJ 400NW TRANSCEIVER 1 1 FRONT SIDE TOP OVERVIEW 1 2 LCD DISPLAY ...

Page 5: ...se of pressing the monitor key for less then 2Sec checks the channel in use scanning each channel Then monitor operation stops as monitor key is released The receive mode begins CASE 2 In case of pressing the monitor key for 2Sec stop to the channel in use and keeps the receive mode until identifying the next monitor key When the monitor key is pressed The current operation stop and returns to the...

Page 6: ...ransceiver See Call Mode section Whether it is in bad condition or has a different tone CTCSS DCS in spite of same frequency it can t be received In normal it can receive all signals by pressing the monitor button and it continues the monitor mode by pressing the button for 2 seconds Press the monitor button again to release the monitor mode Select the channel for the call 2 8 ACCESSORY CONNECTOR ...

Page 7: ...ABLE The T O T Feature ends a transmission which is over 60 seconds in length after time out a continuous alert tone sounds until The PTT switch is released 2 13 CHANNEL SCAN To initiate the scan feature Rotate the channel selector to the location with the scan list programmed to it 1 Non priority channel scan 2 Priority channel scan 2 14 DEFINITION OF PRIORITY CHANNEL Only one priority channel Pa...

Page 8: ...time scan to other PJ 400NW transceivers 1 Prepare the cable PECLONA for PJ 400NW Available in agency 2 Turn on the source transceiver with PTT button pressed and turn on the target transceiver with E button pressed 3 The clone mode message is displayed on the source s LCD and the program mode message is displayed on the target s LCD 4 Connect the cloning cable to EAR MIC jack of both transceivers...

Page 9: ...16 ohm 126mm H 53mm W 38mm D 310g 7 5V DC rechargeable Li MH battery pack 6 75 8 25VDC Receive mode rated audio out 340mA Audio Max Transmit mode 2 0AH Standby mode 70mAH hour battery saver on hour battery saver off RECEIVER Sensitivity Squelch Sensitivity Selectivity Spurious and Harmonic Rejection Intermodulation FM Hum and Noise Maximum Frequency Spread Audio Output Power Audio Distortion Audio...

Page 10: ...z 50 ohms TRANSMITTER RF Power Output Spurious and Harmonic FM Hum and Noise Audio Distortion Audio Frequency Response Maximum Channel Spread Output Impedance 4 1Watt 60dB 40dB 12 5KHz 45dB 25KHz 5 maximum with 1kHz modulation 1 3dB from 6dB per octave pre emphasis characteristic from 300 3000Hz 40MHz 50 ohms ...