TEMPERATURE CONTROL AND PROTECTION SYSTEM

395nm UV LEDs

Ultrasonic

Range Finder

Trigger

Switch

Press & hold for

more than 5 seconds

the display screen will 

show the current 

temperature of the light

1

2

4

WWW.UNILITE.CO.UK

- Press and hold the          button for more than 5 
seconds        when  the  Lamp  is  powered  on,  the 
display screen will show the current temperature   
of the lamp.
- The Lamp has a built-in cooling system which will 
automatically activate when the lamp temperature 
reaches 40°C (104°F) or more.
- When the lamp temperature reaches above 75°C 
(167°F)  and  below  90°C  (194°F)  ,  a  warning 
buzzer will activate and gives an alarm every 30 
seconds  during  the  regular  working  period.  The 
buzzer will stop when the end of the countdown 
shows “               ” or the lamp is turned off manually. 
- When the lamp temperature is above 90°C 

(194°F) , the lamp will automatically switch off and 
the  cooling  system  will  keep  running  until  the 
temperature drops below 50°C (122°F). The lamp 
can  not  be  used  during  this  period  until  the 
temperature is lower than 50°C (122°F) .
- It is recommended that the lamp is allowed to 
cool  down  for  few  minutes  after  each  cure  and 
ensure it is switched off . It will ensure that your 
equipment cures at optimum efficiency and gives a 
longer working life.

1

2

UV-CURE

 

CURING LAMP 

/ 395nm

Summary of Contents for UV-CURE

Page 1: ...WARNING Read this manual before using this product Failure to do so can result in serious injury KEEP THIS MANUAL FOR REFERENCE UV CURE PROFESSIONAL RECHARGEABLE CURING LAMP...

Page 2: ...le switched on risk of fire WARNING Up to 1s curing time for some UV primers Powerful irradiance with maximum UV A intensity of 55 000 W cm at 20 cm 8 inches Successfully tested on UV paint products b...

Page 3: ...2 3 4 5 6 TECHNICAL SPECIFICATIONS Ultrasonic Range Finder Temperature Control Function Safety Protection Function Curing Distance Curing Area Curing Time Average Irradiance Peak Irradiance Max 400cm...

Page 4: ...keep flashing Press or button to adjust the minutes required max 10 Press button again to enter the seconds setting mode seconds display keep flashing Press or button to adjust the seconds required ma...

Page 5: ...75 C 167 F and below 90 C 194 F a warning buzzer will activate and gives an alarm every 30 seconds during the regular working period The buzzer will stop when the end of the countdown shows or the lam...

Page 6: ...onto the 15V 1 5A universal charger Switch the light off and put it in the wall mounted charging station Connect the charging station with the 15V 1 5A universal charger The charging port on the handl...

Page 7: ...the event of any doubt Dispose of any packaging materials via an environmentally friendly disposal facility WARRANTY The device has a 1 year WARRANTY against manufacturing faults or defects The guara...

Reviews: