8
UNiKA NBB-04R / NBB-04T
User Guide
Side Panels
Bottom Panel
This is where you can find the serial number and the
factory assigned Dante default name of your NBB-
04R/NBB-04T. The Dante name of your device can be
changed to whatever you like by using Dante Controller
software.
The two Ethernet ports actually belongs to the two physical ports in the internal
mini switch in NBB-04R/NBB-04T. These allow several NBB-04Rs/NBB-04Ts to
be cascaded in the same Ethernet link for network expanding. The NBB-04R/
NBB-04T can be powered by either of these two ports, provided the the Ethernet
cable on it is from a Ethernet switch with PoE PSE capability. Please be informed
that NBB-04R/NBB-04T does not have the PoE PSE capability to power the next
cascaded PoE PD device, although itself can be powered by PoE.
Besides powered by the Ethernet switch with PoE PSE capability, the NBB-04R/
NBB-04T can also be powered by a 48V power adapter. We ship NBB-04R/NBB-
04T with a 48V adapter in the package in case you don't have Ethernet switch
with PoE PSE capability.
A default button on one of the side panels is used to restore the settings of NBB-
04R/NBB-04T to factory default. Press and hold the switch when you powering
up the device will restore the device to default state. Once you see both SYS and
SYNC LEDs red, you can then re-power the device for the default settings to take
effect. The cap of the default button is sunk to panel to avoid your accidentally
triggering the action of default restoring.