50.11 Change Password
5.11.1 Send SMS
“pold pspace+new password” to the unit to change the
password.
For example: send SMS “password123456 888888” to the unit. If succeeded, “password ok” will
reply to your cell phone from the device tracker.
5.11.2 Be sure to keep the new password in mind, you have to upload the software to restore the
original setting in case of losing the new password.
5.11.3 Attention: Make sure the new password is in 6 digits Arabic numbers, or else the tracker
cannot recognize the password.
5.11.4 The “+” in the command, please don’t type “+”, space means press the space keyboard on
your cell phone
5.12 Authorization
There are only 5 cell phone numbers able to be authorized,
be sure to set the authorization phone
number before use.
5.12.1 Call the tracker for 10 times continuously and get position correctly, then it will make the cell
phone number as the authorized number automatically.
5.12.2 Authorization Send SMS
:
“admin+pspace+cell phone number” to set up a
authorized number. The other authorized numbers should be set by the first authorized number. If
the number is successfully authorized, the unit will reply “admin ok!” in SMS.
5.12.3 Delete authorization Send SMS
:
“pspace+authorized number” to delete
the authorized number.
5.12.4 For roaming purpose, you have to add your country code ahead of the cell phone number,
for example, please send
:
“admin8613322221111” to tracker to set 13322221111 as an
authorized number.
5.13. Terminal (local) Time Setting
5.13.1 Send SMS command “time+space+zone+pspace+time” to the tracker unit, If
succeed, It will reply “time OK”
For example: Send SMS “time zone123456 8”, 8 is Chinese time zone, If your country time zone is
minus, send SMS “time zone123456 -8”.
。
5.13.2 In main interface,Short-
press button”PAGE” to enter time zone interface
And choose local time zone, then short-press SOS button to save