Refer to the enclosed handbooks for the use and maintenance of the pump and
pressure regulator and any accessories or motors.

b)

Please contact the agent in your zone, the nearest authorised workshop or

UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of
performing alone. (see point 8.4)

c)

Due to the complexity of the equipment and the variety of technologies used

(mechanical, hydraulic, oil-pressure and electrotechnical) operators must not
dismantle or modify the equipment. All of the relevant operations must be
performed by specialised personnel, authorised by UNIGREEN S.p.A.

2.4.1 TAKING PRECAUTIONS AGAINST FIRE HAZARDS

Don’t use naked flames or heat sources near the machines.
The mistblowers are made with many materials that derive from petroleum: tanks,
tubes, pipes and hoses, wheels and plastic parts; furthermore the presence of oils
of various nature and residues of chemical products make them potentially
flammable.

2.5

WEATHER CONDITIONS

We recommend spraying in the early hours of the morning or late in the afternoon,
avoiding the hottest time of day.
Never do any spraying if it’s raining or rain is forecast.
Don’t spray in strong wind or in any case, in winds above 3/5 m/second.
If you have to spray in windy conditions, use relatively low pressures to obtain
quite large drops that are less sensitive to drifting (being heavier the wind has less
effect). There are also special anti-drift nozzles available from UNIGREEN S.p.A.;
for information, please contact our offices.

2.6

MACHINES DESIGNED TO BE USED ONLY WITH CLEAN WATER

There are versions of the machines designed only to be used with a hose reel for
washing with cold clean water.
These machines cannot be used with chemical products as they don’t have some of
the devices or accessories that are needed to use these products safely.
These machines are identified by the word “washing” on the CE plate.

2.7

DRIVING ON THE ROAD

The towed mistblowers are not specifically designed for road use. Nevertheless,
many models are also available in the version homologated for road traffic with the
tank empty.
You should check with your local reseller on the correct couplings to use and use
tractors that meet the regulations in force.

3

CHARACTERISTICS AND SPECIFICATIONS

This handbook is valid for mounted and towed mistblowers with axial fans for
phytosanitary treatment in orchards and vineyards, in any case for arboreal
cultivation in rows of varying nature and type.
It is also valid for cannon mistblowers for the phytosanitary treatment of tall plants
and forest trees such as poplars or similar.
The axial mistblowers produce a mixed spray, breaking the drops with the
pressure and the speed of the air produced by the fan.
These mistblowers produced by UNIGREEN SPA are identified by the CE plate
(FIG. 2) bearing one of the marks indicated in the tables of the allowed fittings
(see the following paragraph).

3.1

TABLES OF FITTINGS ALLOWED

Table N° 18a let you identify the version of your machine indicating the basic
equipment and all the possible fittings available (optional).
You can also find the other fittings allowed or other versions to meet your
requirements in the future.

THE EQUIPMENT DEFINED IN THE TABLES OF THIS HANDBOOK (TAB: 18a,
page 31) SHOULD BE CONSIDERED BINDING FOR THE VALIDITY OF THE
DECLARATION OF CONFORMITY.
Other fittings or setups of basic components and/or optionals should be
considered unsafe and therefore are not covered by the guarantee and aren’t
UNIGREEN’s responsibility.
The same goes for fittings realised with components or accessories that aren’t
original UNIGREEN parts.
UNIGREEN accessories can easily be identified by the label with the yellow
background “ORIGINAL UNIGREEN ACCESSORY”

TYPE :  .......................................................................

code: ........................................

N˚   ...........................

massa a vuoto: ..........................Kg.

max  press. : ........... bar

         net mass

       massa totale ammessa:  .............................. Kg.
          total mass

via Rinaldi, 105 - Reggio Emilia ITALIA

ANNO

YEAR

20 .......

made in

Italy

FIG.2

Summary of Contents for Minibar

Page 1: ...04 2010 USE AND MAINTENANCE MANUAL MISTBLOWERS AIRDROP MFC MOUNTED MISTBLOWERS serie AIRDROP P ELETTRA P MFC P Ventagli Minibar Super Spalliera RV GDC Read this manual carefully before use GB...

Page 2: ...ACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4 8 1 COMPONENTS OF TH...

Page 3: ...8 7 1 MATERIALS FOR DEMOLITION 24 8 7 2 INDICATIONS FOR A SUITABLE TREATMENT OF WASTE 24 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 24 TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI FANS VR CANOP...

Page 4: ...work speed over that indicated in the spraying tables in the handbook or too high for the conditions of the terrain use of herbicide booms without an auto levelling system or with the auto levelling s...

Page 5: ...h the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous pictograms 20 19 22 21 2 1 6 3 4 5...

Page 6: ...se only after having carefully read the instructions on the container 2 3 1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accidents Keep the machine in a su...

Page 7: ...ese machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed mistblowers are not specifically designed for road use Nevertheless many models are also available in...

Page 8: ...omponents for hydraulic and pneumatic transmissions Hydraulics UNI EN ISO 4254 1 June 2006 Agricultural machines Safety Part 1 General requisites ISO 11684 1995 Pictograms general principles 4 INSTRUC...

Page 9: ...fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the lifting g...

Page 10: ...Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the third point tie...

Page 11: ...the pump FIG 7 NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING TRACTOR POWER TAKEOFF PROTECTIVE COVER CARDAN SHAFT PROTECTIVE COVER FIXED PROTECTIVE COVER ON THE PUMP...

Page 12: ...ion regulator G D auxiliary tap can be used for various accessories it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically...

Page 13: ...t the corresponding compensator G until you return to the pressure set previously displayed on the manometer open and close the tap of section C and check that the pressure remains constant repeat the...

Page 14: ...and after filling stop the pump and put the lever of deviator D back in the working position disconnect pipe T from deviator D b FILLING WITH THE SUCTION FILTER Fig 3 Fig 11 If the 3 way deviator isn...

Page 15: ...llow for using chemical products are indicated in paragraph 2 2 1 4 12 2PREMIXER ON COVER OPTIONAL Open the cover and pour all of the chemical powder into the filter close the cover and open the suppl...

Page 16: ...the power takeoff b Check you have filled the circuit washer tank C c Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed d Turn suction deviator A to...

Page 17: ...to engage the fan rotor gradually This prevents jerky starts due to the inertia of the fan rotor which can have a negative effect on the transmission For the centrifugal clutch to work properly the s...

Page 18: ...er versions moving the left hand distributor to the right hand and vice a versa the same inversion must be performed for the two distributor taps 1 2 3 4 For particularly high espaliers an upper doubl...

Page 19: ...components and in particular to the pipes to prevent the risk of bursting Do a full check on the pipes and components at least once a year we recommend replacing hydraulic pipes every 3 4 years 5 4 1...

Page 20: ...means a big advantage in terms of uniformity and homogeneity of the jet 6 3 MIXTURE CONCENTRATION As you may know the pneumatic equipment are used for more or less concentrated treatments To prepare t...

Page 21: ...ce 3 5 m volume in l ha 600 x 5 6 177 8 l ha 3 5 x 5 4 6 4 1 BATCHING TAPS SEE PICTURE 20 On the equipment VENTAGLI FANS there are two batching taps which can be used to quickly change the flow rate t...

Page 22: ...e is controlled by opening lever A which depending on how much it s pressed produces a conical spray or direct jet The standard nozzle is 1 5 The mitra spray gun can produce a direct jet or a conical...

Page 23: ...lly in the first period of use We recommend replacing the oil after the first 50 working hours and then subsequently every 500 hours The quantity of oil needed is indicated on the sticker near the mul...

Page 24: ...TABLE TREATMENT OF WASTE The Correct management of special waste envisages stocking in suitable places avoiding mixing dangerous waste with the non dangerous ensuring that authorised carriers and rece...

Page 25: ...137 154 173 192 233 263 281 324 365 370 425 477 472 535 8 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468 2 5 m 4 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 5 150 160 180...

Page 26: ...5 150 160 189 216 253 280 302 346 384 6 80 91 96 125 133 157 180 211 233 252 288 320 3 7 69 78 82 107 114 135 154 181 200 216 247 274 8 60 68 72 94 100 118 135 158 175 189 216 240 3 m Litri min 2 40 2...

Page 27: ...TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 0578F Velocit Km h speed Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Page 28: ...17 3 19 2 20 1 21 5 TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 000F Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Page 29: ...1 5 nozzle DIAMETER NOZZLE 1 0 1 2 1 5 1 75 2 0 2 2 2 5 PRESSURE BAR JET CAPACITY Lt min 5 cone 1 16 1 40 1 90 2 25 2 65 2 90 3 50 direct jet 1 40 1 70 2 50 3 95 4 7 6 00 7 70 8 cone 1 40 1 80 2 60 2...

Page 30: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 31: ...1 X X X X APS 96 PRESSURE GCP 2 ELECTRIC X X X X REGULATOR GCP 2 ELECTRIC PRES X X X X NOZZLES MFC X X X X DISTRIBUTOR 2 VENTAGLI X X X X ACCESSORIES MINIBAR X X X X SUPER SPALLIERA X X X X RV X X X R...

Page 32: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: