Unigreen Minibar Use And Maintenance Manual Download Page 27

unigreen  

27

TABLES FOR CALIBRATING AIRDROP MINIBAR

AIRDROP CALIBRATING TABLES

N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width
indicated in the table and divide it by the new width (see chapter 6.4, page 21).

unigreen spa

Tabella erogazione in Litri/ettaro per MINIBAR spalliera (6 diffusori)

MFC ® system

Lt./ha spreading rate table  - MINIBAR

PIASTRINA CALIBRATA

Calibrated plate

4916/40

4916/47

4916/55

4916/70

Larghezza di lavoro

PRESSIONE bar

1,5

2

2,5

3

1,5

2

2,5

3

1,5

2

2,5

3

1,5

2

2,5

3

working width

3,5

276 313 362 395 456 504 536 572 539 597 646 692 892 990 1035 1107

4

241 274 317 346 399 441 469 501 472 523 565 606 780 866 905 969

5

193 219 253 276 319 353 375 401 378 418 452 484 624 693 724 775

2,5

6

161 182 211 230 266 294 313 334 315 348 377 404 520 577 604 646

7

138 156 181 197 228 252 268 286 270 299 323 346 446 495 517 554

2,5 m.

3,5

230 261 302 329 380 420 447 477 449 498 538 577 743 825 862 923

4

201 228 264 288 332 367 391 417 393 436 471 505 650 722 755 807

5

161 182 211 230 266 294 313 334 315 348 377 404 520 577 604 646

3

6

134 152 176 192 222 245 261 278 262 290 314 336 433 481 503 538

7

115 130 151 165 190 210 223 238 225 249 269 288 371 412 431 461

3 m.

3,5

197 223 259 282 326 360 383 409 385 427 461 494 637 707 739 791

4

172 195 226 247 285 315 335 358 337 373 403 433 557 619 647 692

5

138 156 181 197 228 252 268 286 270 299 323 346 446 495 517 554

3,5

6

115 130 151 165 190 210 223 238 225 249 269 288 371 412 431 461

7

98

112 129 141 163 180 191 204 193 213 231 247 318 354 370 395

3,5 m.

Litri/min.

4,02 4,56 5,28 5,76 6,65 7,34 7,82 8,35 7,87 8,71 9,41 10,1

13

14,4 15,1 16,1

TOTALE / total

Litri/min.

0,67 0,76 0,88 0,96 1,11 1,22

1,3

1,39 1,31 1,45 1,57 1,68 2,17 2,41 2,52 2,69

SINGOLA / single

Tab. 3215/0578F

Veloc

ità Km/h

s

p

eed

Litri/ha

Litri/ha

Litri/ha

Veloc

ità Km/h

s

p

eed

Veloc

ità Km/h

s

p

eed

unigreen spa

Tabella erogazione in Litri/ettaro per MINIBAR spalliera (8 diffusori)

MFC ® system

Lt./ha spreading rate table  - MINIBAR (8 diffusors)

PIASTRINA CALIBRATA

Calibrated plate

4916/40

4916/47

4916/55

4916/70

Larghezza di lavoro

PRESSIONE bar

1,5

2

2,5

3

1,5

2

2,5

3

1,5

2

2,5

3

1,5

2

2,5

3

working width

3,5

368 417 483 527 608 671 715 763 719 797 861 923 1189 1320 1380 1476

4

322 365 422 461 532 588 625 668 629 697 753 807 1040 1155 1207 1292

5

257 292 338 369 425 470 500 534 503 558 602 646 832 924 966 1033

2,5

6

214 243 282 307 355 392 417 445 420 465 502 538 693 770 805 861

7

184 208 241 263 304 336 357 382 360 398 430 461 594 660 690 738

2,5 m.

3,5

306 347 402 439 507 560 596 636 599 664 717 769 991 1100 1150 1230

4

268 304 352 384 443 490 521 556 524 581 628 673 867 962 1006 1076

5

214 243 282 307 355 392 417 445 420 465 502 538 693 770 805 861

3

6

179 203 235 256 295 326 347 371 350 387 418 449 578 642 671 718

7

153 174 201 219 253 280 298 318 300 332 359 384 495 550 575 615

3 m.

3,5

263 298 345 376 434 480 511 545 514 569 615 659 849 943 985 1054

4

230 261 302 329 380 420 447 477 449 498 538 577 743 825 862 923

5

184 208 241 263 304 336 357 382 360 398 430 461 594 660 690 738

3,5

6

153 174 201 219 253 280 298 318 300 332 359 384 495 550 575 615

7

131 149 172 188 217 240 255 273 257 284 307 330 425 471 493 527

3,5 m.

Litri/min.

5,36 6,08 7,04 7,68 8,86 9,79 10,4 11,1 10,5 11,6 12,6 13,5 17,3 19,2 20,1 21,5

TOTALE / total

Litri/min.

0,67 0,76 0,88 0,96 1,11 1,22

1,3

1,39 1,31 1,45 1,57 1,68 2,17 2,41 2,52 2,69

SINGOLA / single

Tab. 3215/0578F

Litri/ha

Litri/ha

Litri/ha

Veloc

ità Km/h

s

p

eed

Veloc

ità Km/h

s

p

eed

Veloc

ità Km/h

s

p

eed

OPTIONAL

Summary of Contents for Minibar

Page 1: ...04 2010 USE AND MAINTENANCE MANUAL MISTBLOWERS AIRDROP MFC MOUNTED MISTBLOWERS serie AIRDROP P ELETTRA P MFC P Ventagli Minibar Super Spalliera RV GDC Read this manual carefully before use GB...

Page 2: ...ACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4 8 1 COMPONENTS OF TH...

Page 3: ...8 7 1 MATERIALS FOR DEMOLITION 24 8 7 2 INDICATIONS FOR A SUITABLE TREATMENT OF WASTE 24 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 24 TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI FANS VR CANOP...

Page 4: ...work speed over that indicated in the spraying tables in the handbook or too high for the conditions of the terrain use of herbicide booms without an auto levelling system or with the auto levelling s...

Page 5: ...h the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous pictograms 20 19 22 21 2 1 6 3 4 5...

Page 6: ...se only after having carefully read the instructions on the container 2 3 1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accidents Keep the machine in a su...

Page 7: ...ese machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed mistblowers are not specifically designed for road use Nevertheless many models are also available in...

Page 8: ...omponents for hydraulic and pneumatic transmissions Hydraulics UNI EN ISO 4254 1 June 2006 Agricultural machines Safety Part 1 General requisites ISO 11684 1995 Pictograms general principles 4 INSTRUC...

Page 9: ...fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the lifting g...

Page 10: ...Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the third point tie...

Page 11: ...the pump FIG 7 NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING TRACTOR POWER TAKEOFF PROTECTIVE COVER CARDAN SHAFT PROTECTIVE COVER FIXED PROTECTIVE COVER ON THE PUMP...

Page 12: ...ion regulator G D auxiliary tap can be used for various accessories it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically...

Page 13: ...t the corresponding compensator G until you return to the pressure set previously displayed on the manometer open and close the tap of section C and check that the pressure remains constant repeat the...

Page 14: ...and after filling stop the pump and put the lever of deviator D back in the working position disconnect pipe T from deviator D b FILLING WITH THE SUCTION FILTER Fig 3 Fig 11 If the 3 way deviator isn...

Page 15: ...llow for using chemical products are indicated in paragraph 2 2 1 4 12 2PREMIXER ON COVER OPTIONAL Open the cover and pour all of the chemical powder into the filter close the cover and open the suppl...

Page 16: ...the power takeoff b Check you have filled the circuit washer tank C c Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed d Turn suction deviator A to...

Page 17: ...to engage the fan rotor gradually This prevents jerky starts due to the inertia of the fan rotor which can have a negative effect on the transmission For the centrifugal clutch to work properly the s...

Page 18: ...er versions moving the left hand distributor to the right hand and vice a versa the same inversion must be performed for the two distributor taps 1 2 3 4 For particularly high espaliers an upper doubl...

Page 19: ...components and in particular to the pipes to prevent the risk of bursting Do a full check on the pipes and components at least once a year we recommend replacing hydraulic pipes every 3 4 years 5 4 1...

Page 20: ...means a big advantage in terms of uniformity and homogeneity of the jet 6 3 MIXTURE CONCENTRATION As you may know the pneumatic equipment are used for more or less concentrated treatments To prepare t...

Page 21: ...ce 3 5 m volume in l ha 600 x 5 6 177 8 l ha 3 5 x 5 4 6 4 1 BATCHING TAPS SEE PICTURE 20 On the equipment VENTAGLI FANS there are two batching taps which can be used to quickly change the flow rate t...

Page 22: ...e is controlled by opening lever A which depending on how much it s pressed produces a conical spray or direct jet The standard nozzle is 1 5 The mitra spray gun can produce a direct jet or a conical...

Page 23: ...lly in the first period of use We recommend replacing the oil after the first 50 working hours and then subsequently every 500 hours The quantity of oil needed is indicated on the sticker near the mul...

Page 24: ...TABLE TREATMENT OF WASTE The Correct management of special waste envisages stocking in suitable places avoiding mixing dangerous waste with the non dangerous ensuring that authorised carriers and rece...

Page 25: ...137 154 173 192 233 263 281 324 365 370 425 477 472 535 8 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468 2 5 m 4 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 5 150 160 180...

Page 26: ...5 150 160 189 216 253 280 302 346 384 6 80 91 96 125 133 157 180 211 233 252 288 320 3 7 69 78 82 107 114 135 154 181 200 216 247 274 8 60 68 72 94 100 118 135 158 175 189 216 240 3 m Litri min 2 40 2...

Page 27: ...TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 0578F Velocit Km h speed Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Page 28: ...17 3 19 2 20 1 21 5 TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 000F Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Page 29: ...1 5 nozzle DIAMETER NOZZLE 1 0 1 2 1 5 1 75 2 0 2 2 2 5 PRESSURE BAR JET CAPACITY Lt min 5 cone 1 16 1 40 1 90 2 25 2 65 2 90 3 50 direct jet 1 40 1 70 2 50 3 95 4 7 6 00 7 70 8 cone 1 40 1 80 2 60 2...

Page 30: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 31: ...1 X X X X APS 96 PRESSURE GCP 2 ELECTRIC X X X X REGULATOR GCP 2 ELECTRIC PRES X X X X NOZZLES MFC X X X X DISTRIBUTOR 2 VENTAGLI X X X X ACCESSORIES MINIBAR X X X X SUPER SPALLIERA X X X X RV X X X R...

Page 32: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...