PART I: SPECIFICATIONS
6
Technical Specifications
Country and usefulness gas categories
BURNER TYPE
TLX512-FGR
TLX515-FGR
TLX520-FGR
TLX525-FGR
Output
min - max kW
1280 - 3600
1065 - 4160
1600 - 4816
1550 - 6320
Fuel
Natural gas
Category
(see next paragraph)
Gas rate
min.-max. (Stm3/h)
135 - 381
113 - 440
169 - 510
164 - 669
Gas pressure
(see Note 2)
Controls power supply
400V ac. 50 Hz
Total power consumption
kW
0,5
0,5
0,5
0,5
Protection
IP54
Operation
MD - Fully modulating
Rp 2”
Rp 2”
Rp 2”
-
Gas train
ØValves / Connections
65 / DN65
65 / DN65
65 / DN65
65 / DN65
80 / DN80
80 / DN80
80 / DN80
80 / DN80
100 / DN100
100 / DN100
100 / DN100
100 / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service
Continuous
Note1:
All gas flow rates are referred to Stm
3
/ h (1.013 mbar absolute pressure, 15° C temperature) and are valid for G20 gas
(net calorific value H
i
= 34,02 MJ / Stm
3
= 9,45 kWh / Stm
3
);
Note2:
Maximum gas pressure= 500 mbar (with
Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure= see gas curves.
Warning:
Burners are suitable only for indoor operation with a maximum relative humidity of 80%
GAS
CATEGORY
COUNTRY
I
2H
AT ES GR SE
FI
IE
HU
IS NO CZ DK GB
IT
PT CY EE LV
SI
MT SK BG LT RO TR CH
I
2E
LU
PL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2E( R ) B
BE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
(*) I
2EK
NL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2ELL
DE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2Er
FR
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
(*) Only for I
2EK
: the appliance was configured for the appliance category K (I2K) and is suitable for the use of G and G+ distribution gases according to the specifications as
included in the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0 °C, upper value) or 41.23 – 42.98 (dry, 15 °C, upper value). This appliance can
moreover be converted and/or be calibrated for the appliance category E (I2E). This therefore implies that the appliance “is suitable for G+ gas and H gas or is demonstrably
suitable for G+ gas and can demonstrably be made suitable for H gas” within the meaning of the “Dutch Decree of 10 May 2016 regarding amendment of the Dutch Gas
Appliances Decree and the Dutch Commodities (Administrative Fines) Act in connection with the changing composition of gas in the Netherlands as well as technical
amendment of some other decrees.
Summary of Contents for TLX512-FGR
Page 41: ...PART IV MAINTENANCE 41...
Page 42: ......
Page 43: ......
Page 45: ...Siemens LMV5x Service Manual M12920CC rev 2 1 08 2017...
Page 52: ...8...
Page 56: ...12 2 2 LMV5x program structure...
Page 83: ...39...
Page 90: ......
Page 91: ......
Page 92: ...Note Specifications and data subject to change Errors and omissions excepted...
Page 94: ...Annex1 Example for motor cable...
Page 95: ......
Page 96: ...Annex 2 Example for sensor cable...
Page 97: ......
Page 98: ......
Page 102: ......