Installation
Mounting
Installation
• A fixed electrical installation must be done by an authorized electrician.
• Maximum five units may be connected in a fixed electrical installation.
• The unit shall be placed in a dry environment with a temperature range from +5° C to + 40° C
(41° F to 104° F).
• The unit shall be mounted to a vertical wall.
• The unit shall be mounted to concrete or plaster walls only.
• Avoid mounting the unit in a sunlit place. This can affect the charging capacity.
Delivery Includes
• Battery Pack Charger
• Power cord including IEC C14 connector (male)
• Inlet accessory kit, including cable support holders and screws
A suitable extension cord is needed to connect a single unit to a wall outlet, unless the C14 con-
nector is replaced (by an electrician). The following item can be ordered from Siemens Enter-
prise Communications GmbH & Co. KG:
Item
Item Number
EU cord
L30280-Z600-F105
UK cord
L30280-Z600-F102
SWZ cord
L30280-Z600-F103
US cord
L30280-Z600-F101
Required Tools etc.
• Screwdrivers
• Cutting pliers
• Multimeter
• Screws and wall plugs for wall mounting.
Make sure the screws and wall plugs have the correct length for the type of wall used.
Wall material
Plug length
Screw diameter
Single plasterboard
Thorsman TP1
3.5 – 5 mm
Double plasterboard
Thorsman TP2
3.5 – 5 mm
Concrete
Thorsman TP2
3.5 – 5 mm
Mounting
1)
First, make an outline of how the units are to be placed.
2)
If several Battery Pack Chargers (or Charging Racks) are to be mounted close to each oth-
er, mount them so that there is enough space between them to be able to disconnect the bat-
teries or the handsets (vertical distance) and to be able to open the top cover (horizontal dis-
tance).
When you are planning the location of the units, start to mount them in a height that makes it
easy to reach the batteries.
A31003-M2000-J106-01-7631, 25/06/2020
Battery Pack Charger, Installation Guide